• Vacuum Circuit Breaker 24 kV , the next generation of HVX digital MV Circuit Breaker
Vacuum Circuit Breaker 24 kV , the next generation of HVX digital MV Circuit Breaker
discuss personally
Model
PacT Series EvoPacT HVX-24
Basic info
Brand Schneider
Model NO. Vacuum Circuit Breaker 24 kV , the next generation of HVX digital MV Circuit Breaker
Rated voltage 24kV
Series PacT Series EvoPacT HVX
Product Detail

Overview

EvoPacT HVX is a range of Vacuum Circuit Breakers (VCB), addressing 24 kV networks, with up to 31.5 kA short circuit capacities and ranging from 630 A to 2500 A. It is designed for use in Medium Voltage switchgear to connect primary power distribution consumers to the power grid. EvoPacT HVX digital circuit breakers are designed with more than 45 years of medium-voltage experience and manufactured using in-house, best-in-class components for a longer operational life. With innovative features, EvoPacT HVX uses digital features to help mitigate risks for facilities and the people who work in them

General characteristics

According to IEC 62271-100:2021
Main electrical characteristics:

 

Operating conditions

According to IEC 62271-100:2021
Main electrical characteristics:

Other service conditions

If operated beyond the normal service conditions, the circuit breaker is submitted to accelerated aging. The circuit breaker may only be used under conditions other than the normal service conditions with express written permission from Schneider Electric.

Storage

In order to preserve all of the device’s characteristics when stored for prolonged periods, we recommend to store the device in its original packaging, in dry conditions and sheltered from the sun and rain at a temperature between -40 °C and +70 °C. The maximum storage period is 12 months.

If the device was stored:

  •  Between 6 and 12 months: perform basic preventive maintenance to help ensure correct device operation
  •  Beyond 12 months: contact your Schneider Electric Service local representative  for device check-up

 

Fixed Circuit Breaker dimensions

 

Withdrawable Circuit Breaker dimensions

 

Modules description

Know your supplier
Schneider
Chengdu Fabo Automation Complete Equipment Co., Ltd is an authorized distributor of Schneider Electric, a global leader in energy management and automation solutions.
Main Categories
High voltage/Low voltage
Business Type
Manufacture/Sales
Highest Annual Export (USD)
$400000000
Professional Experience
10 years
Workplace
20000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!