• 150 kVA Single Phase Pole Mounted Transformer
150 kVA Single Phase Pole Mounted Transformer
discuss personally
Model
DR11-150/10
Basic info
Brand Vziman
Model NO. 150 kva Single Phase Pole Mounted Transformer
Rated capacity 150KVA
Series Single Phase Pole Mounted Transformer
Product Detail

Product overview: 

  • WONE is a professional manufacturer of distribution transformers with 10 years of manufacturing experience. 

  • The single-phase Pole-Mounted transformers designed and produced are usually used for urban and rural power distribution .

  • Input voltages:11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv; Output voltage:240 / 480v, 120 / 240V, etc. 

  • Executive Standards: IEEE C57, ANSI C57, IEC60076 

Leading technology:

  •  Unique winding technology to improve lightning resistance.

  • Small magnetic leakage, high mechanical strength, strong short circuit resistance.

  • Iron core 45° full oblique joint step laminated structure.

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 50 years of paint (coating corrosion resistance within 100h, hardness ≥0.4.

  • Cylindrical fully sealed construction with self-sealing manual pressure relief valve (according to ANSI specification.

  • Standard NEMA hanger bracket (each device includes pole support bracket plate.

  • Fully sealed structure, maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from Baowu Steel Group, China).

  •  Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

winding:

  • Low voltage windings are made of high quality cable paper wrapped wire.

  • High voltage windings are made of high quality polyurethane enamelled round copper wire.

  • Interlayer insulation using dot adhesive paper, so that the coil bonding into a fixed unit, with excellent insulation resistance.

  • Transformer structure is reliable during normal operation and transportation.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • High quality anaerobic copper from China.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

other:

  •  High strength polymer low pressure casing or high and low pressure porcelain casing.

  •  Equipped with ring type full copper tinned terminal.

  • Install limited current fuses and arresters.

Product parameters:

  •  Input voltage: 11kv, 12.4kv, 13.2kv, 13.8kv and 34.5kv.

  • Output voltage: 0.4kv 0.416 kv 0.420kv 0.440kv 0.480kv.

  • Capacity: 5-167 kva.

  •  Frequency: 50/60 HZ.

  •  Remark: voltage, capacity, frequency, connection group and loss can be customized according to customer requirements.

Ordering instructions:

  •  Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer use environment (altitude, temperature, humidity, place, etc) .

  • Other customized requirements (tap switch, color, oil pillow, etc) .

  • The minimum order quantity is 1 set, global delivery within 7 days .

  • The normal delivery period is 30 days, with fast delivery worldwide .

What is a single-phase pole-mounted transformer?


The 150 kVA single-phase pole-mounted transformer is a common type of distribution equipment, mainly used to convert high-voltage electrical energy into low-voltage electrical energy suitable for users. This kind of transformer is usually installed on utility poles and is applicable to power distribution in rural, suburban, and some urban areas. The following is a detailed explanation of the 150 kVA single-phase pole-mounted transformer:

Definitions and Characteristics:

  • Single-phase: It means that the transformer has a single independent winding and is applicable to single-phase alternating current systems.

  • Pole-mounted: It means that the transformer is installed on a utility pole and is usually used for outdoor power distribution.

  • 150 kVA: It indicates that the rated capacity of the transformer is 150 kVA, which is suitable for medium-power power distribution.



Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!