| Brand | ROCKWILL | 
| Model NO. | 12kV indoor high-voltage load break switch | 
| Rated voltage | 12kV | 
| Rated normal current | 400A | 
| Rated frequency | 50/60Hz | 
| Series | FN | 
Product Overview
The FN5 - 12 indoor AC high - voltage load break switch (hereinafter referred to as the load break switch) is suitable for AC 50Hz, 12kV networks. It is used for breaking load current and closing short - circuit current. The load break switch with a fuse can cut off short - circuit current and be used as a protection switch.
This load break switch can be equipped with the CS6 - 1 manual operating mechanism and the special CS manual operating mechanism for this product.
Key Features
Precise Current Control:Suitable for 12kV, 50Hz AC systems. It can stably break load current and close short - circuit current, ensuring normal operation and maintenance of the power grid as well as emergency operations during faults.
Extended Protection Function:When paired with a fuse, it can cut off short - circuit current and act as a protection switch, providing overload and short - circuit dual protection for power equipment and simplifying the protection levels of the distribution network.
Wide Scene Adaptability:Focused on indoor 12kV AC networks. It is suitable for typical indoor power distribution scenarios such as ring main units and box - type substations, meeting the needs of distribution network construction.
Flexible Mechanism Configuration:Supports the CS6 - 1 general manual operating mechanism and can also be adapted to the special CS mechanism, compatible with different operating habits and equipment matching requirements.
Mature Technical Architecture:Iterated based on the classic FN5 - 12 model. It has a compact structure, stable arc - extinguishing performance, high long - term operation reliability, and reduces operation and maintenance costs.
Technical Parameters
Name  |  
   Unit  |  
   Value  |  
  
Rated Voltage  |  
   kV  |  
   12  |  
  
Maximum Operating Voltage  |  
   kV  |  
   12  |  
  
Rated Frequency  |  
   Hz  |  
   50  |  
  
Name  |  
   Unit  |  
   Value  |  
  |
Rated Current  |  
   A  |  
   400  |  
   630  |  
  
Rated Short - time Withstand Current (Thermal Stable Current)  |  
   kA/S  |  
   12.5/4  |  
   20/2  |  
  
Rated Peak Withstand Current (Dynamic Stable Current)  |  
   kA  |  
   31.5  |  
   50  |  
  
Rated Closed - loop Breaking Current  |  
   A  |  
   400  |  
   630  |  
  
Rated Active Load Breaking Current  |  
   A  |  
   400  |  
   630  |  
  
5% Rated Active Load Breaking Current  |  
   A  |  
   20  |  
   31.5  |  
  
Rated Cable Charging Breaking Current  |  
   A  |  
   10  |  
  |
Rated No - load Transformer Breaking Current  |  
   No - load Current of 1250kVA Transformer  |  
  ||
Rated Short - circuit Making Current  |  
   kA  |  
   31.5  |  
   50  |  
  
Load Current Breaking Times  |  
   Load/Time  |  
   100%/20  |  
   30%/75  |  
  
1min Power Frequency Withstand Voltage (Effective Value, to Ground, Phase - to - Phase/Isolation Break)  |  
   kV  |  
   42/48  |  
  |
Power Frequency Withstand Voltage, Between Isolation Breaks  |  
   kV  |  
   53  |  
  |
Lightning Impulse Withstand Voltage (Peak Value, to Ground, Phase - to - Phase/Isolation Break)  |  
   kV  |  
   75/85  |  
  |
Opening and Closing Operating Torque (Force)  |  
   N·m (N)  |  
   90(80)  |  
   100(200)  |  
  
Technical Parameters of Fuse
Model  |  
   Rated Voltage (kV)  |  
   Rated Current of Fuse (A)  |  
   Rated Breaking Current (kA)  |  
   Rated Current of Fuse Element (A)  |  
  
RN3 
  |  
   12 
  |  
   50  |  
   12.5  |  
   2, 3, 5, 7.5, 12, 15, 20, 30, 40, 50  |  
  
75  |  
   12.5  |  
   75  |  
  ||
100  |  
   12.5  |  
   100  |  
  ||
200  |  
   12.5  |  
   150, 200  |  
  ||
SDL*J  |  
   12  |  
   40  |  
   50  |  
   6.3, 10, 16, 20, 25, 31.5, 40  |  
  
SFL*J  |  
   12  |  
   100  |  
   50  |  
   50, 63, 71, 80, 100  |  
  
SKL*J  |  
   12  |  
   126  |  
   50  |  
   125  |  
  
Altitude: Not exceeding 1000m;
Ambient Air Temperature: Upper limit +40°C, Lower limit -25°C (Not lower than -5°C for motor - operated mechanisms);
Relative Humidity: Daily average not greater than 95%, Monthly average not greater than 90% (+25°C);
Ambient air should be free from obvious pollution by corrosive or flammable gases, water vapor, etc.;
No frequent severe vibration.