12kV 24kV 36kV Pure air/Nitrogen Insulated Ring Main Unit(RMU) Ensuring Stable Power

  • 12kV 24kV 36kV Pure air/Nitrogen Insulated Ring Main Unit(RMU) Ensuring Stable Power

Key attributes

Brand ROCKWILL
Model NO. 12kV 24kV 36kV Pure air/Nitrogen Insulated Ring Main Unit(RMU) Ensuring Stable Power
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series REC

Product descriptions from the supplier

Description

Description:

ROCKWILL® attaches great importance to product quality and manufacturing technology, and treats every step of product production with precision and meticulousness. Only insulation gas is used to comprehensively compare heating dry air, nitrogen, carbon dioxide, and pure air. Pure air synthesized with extremely low moisture content and high purity is selected as the preferred insulation gas to replace SF6. The core switch unit of the product adopts a brand new vacuum arc extinguishing chamber soft package casting process, combined with a carefully designed rotating three-position switch, with a simple and compact overall structure; The fully sealed gas box replaces SF6 with pure air, with a highly advantageous electric field distribution design, and the partial discharge of the entire cabinet is below 5pC; The salt spray resistance test of the operating mechanism of the zinc inlay alloy surface treatment process has exceeded 168 hours, and the longest service life can reach 30000 times.

Feature:

  • Pure air/Nitrogen insulated ring main unit

  • Environmentally friendly gas

  • Zero carbon emissions, zero waste

  • Intensive and meticulous producing, Seeking finer quality

  • Comply with IEC/ANSI standards

  • Provided customized manufacture

  • Whole solutions for design, assembly, test...

  • Accountable solution for safety and reliability

  • Wide range offering, easy business and convenient installation

Main technical parameters (three phase):

12kV

N

Item

Unit

Data

1

Rated maximum voltage

kV

12

2

Rated maximum current

A

630/1250

3

Rated frequency

Hz

50/60

4

Method of Arc Suppressing


Vacuum

5

Method of Insulation


Pure air/Nitrogen

6

Rated short circuit breaking current

kA

20/25

7

Rated peak value withstand current

kA

50/63

8

Rated 1min power frequency withstand voltage

kV

42

9

Rated lightning impulse voltage

kV

75

10

Operation sequence

/

C-0.3-CO-180-CO

12

Resistance loop

µΩ

≤140

13

Rated gas pressure (20℃ gauge)

Mpa

0.02

14

Minimum operating gas pressure

Mpa

0

15

Mechanical life - Circuit breaker

N

10000


Mechanical life - Load break switch

N

3000/6000


Mechanical life - Disconnector

N

3000/6000


Mechanical life - Earthing switch

N

3000/6000

16

Protection grade - Gas tank


IP67


Protection grade - Shell


IP4X

17

Rated annual air leakage rate

%

0.01

24kV

N

Item

Unit

Data

1

Rated maximum voltage

kV

24

2

Rated maximum current

A

630/1250

3

Rated frequency

Hz

50/60

4

Method of Arc Suppressing


Vacuum

5

Method of Insulation


Pure air/Nitrogen

6

Rated short circuit breaking current

kA

20/25

7

Rated peak value withstand current

kA

50/63

8

Rated 1min power frequency withstand voltage

kV

50

9

Rated lightning impulse voltage

kV

125

10

Operation sequence

/

C-0.3-CO-180-CO

12

Resistance loop

µΩ

≤150

13

Rated gas pressure (20℃ gauge)

Mpa

0.04

14

Minimum operating gas pressure

Mpa

0

15

Mechanical life - Circuit breaker

N

10000


Mechanical life - Load break switch

N

3000/6000


Mechanical life - Disconnector

N

3000/6000


Mechanical life - Earthing switch

N

3000/6000

16

Protection grade - Gas tank


IP67


Protection grade - Shell


IP4X

17

Rated annual air leakage rate

%

0.01

36kV

N

Item

Unit

Data

1

Rated maximum voltage

kV

36

2

Rated maximum current

A

630/1250

3

Rated frequency

Hz

50/60

4

Method of Arc Suppressing


Vacuum

5

Method of Insulation


Pure air/Nitrogen

6

Rated short circuit breaking current

kA

20/25

7

Rated peak value withstand current

kA

50/63

8

Rated 1min power frequency withstand voltage

kV

70

9

Rated lightning impulse voltage

kV

170

10

Operation sequence

/

C-0.3-CO-180-CO

12

Resistance loop

µΩ

≤160

13

Rated gas pressure (20℃ gauge)

Mpa

0.04

14

Minimum operating gas pressure

Mpa

0

15

Mechanical life - Circuit breaker

N

10000


Mechanical life - Load break switch

N

3000/6000


Mechanical life - Disconnector

N

3000/6000


Mechanical life - Earthing switch

N

3000/6000

16

Protection grade - Gas tank


IP67


Protection grade - Shell


IP4X

17

Rated annual air leakage rate

%

0.01

Compact type pure air/nitrogen insulated ring main unit

 

Type

Top extension of single panel

Side extension of single panel

Single panel size of compact module

Circuit Breaker Panel

390 * 850 * 1950

390 * 850 * 1950

390 * 850 * 1950

Load Break Switch Panel

390 * 850 * 1950

390 * 850 * 1950

390 * 850 * 1950

PT Panel (with 3phase, 5 columns)

600 * 850*1950

600 * 850 * 1950

600 * 850 * 1950

PT Panel (single phase)

420 * 850 * 1950

420 * 850 * 2000

420 * 850 * 1600

Bus Riser

375 * 850 * 1950

375 * 850 * 2000

375 * 850 * 1600

Metering panel

750 * 850 * 1950

750 * 850 * 2000

750 * 850 * 1600

 

 

Documentation Resource Library
Restricted
REC-12 Pure air/Nitrogen insulated ring main unit
Brochure
English
Consulting
Consulting
FAQ
Q: What is an environmentally friendly cabinet? What are its main characteristics?
A:
An environmentally friendly cabinet is a medium-voltage power distribution equipment designed to replace traditional SF6 gas-insulated cabinets. Its core characteristics include using eco-friendly insulating media (such as dry air, N2, or N2/CO2 mixture) with low or zero global warming potential (GWP), no environmental pollution after leakage, compact structure, high operational reliability, and suitability for various harsh application scenarios.
Q: How does an environmentally friendly cabinet differ from traditional SF6 gas-insulated cabinets?
A:
The key difference lies in the insulating medium. Traditional cabinets use SF6, a strong greenhouse gas with high GWP. Environmentally friendly cabinets adopt eco-friendly media (dry air, N2, etc.) that are non-toxic, non-greenhouse effect, and require no special recycling. Additionally, eco-friendly cabinets have lower long-term operation and maintenance costs, while their insulation and breaking performance can meet the same industry standards as SF6 cabinets.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.