12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer

  • 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
  • 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer

Key attributes

Brand Rockwell
Model NO. 12kV 24kV 33kV Three Phases Transformer Pad Mounted HV/LV Plug-In Distribution Transformer
Rated voltage 33kV
Rated frequency 50/60Hz
Series H59

Product descriptions from the supplier

Description

Description

With the development of the power industry, driven by urbanization,equipment intensification, technological advancements, and the urgent need for scenario adaptability, Rockwill has successfully developed the Top Mounted High/ Low Voltage Bushing Transformer (commonly known as the H59 earthing/Grounding Distribution Transformer), leveraging years of electrical design experience and integrating global advanced technical concepts.The H59 refers to a power transformer where both the high-voltage and low-voltage bushings are vertically installed on the top of the unit. This structural design allows all high- and low-voltage leads to be routed through the top, making it suitable for scenarios with strict lateral space constraints or requiring vertical busbar connections. It is a common type of oil-immersed transformer.

Service Environment

Temperature:

  • Maximum ambient temperature: +50℃;

  • Top oil temperature rise: +50℃

  • Average winding temperature rise: +55℃

Humidity: Daily average humidity 100%.

Above sea level: Maximum installation altitude: 1000m

Features

  • Reliable Grounding Protection: Specifically designed for grid grounding, it effectively suppresses fault currents to ensure system stability and personnel safety.

  • Outdoor Environment Adaptability: With a sealed pad-mounted structure, it is waterproof, dustproof, and corrosion-resistant, suitable for complex outdoor conditions like humidity and dust.

  • Space-Optimized Design: Pad-mounted installation saves ground space, ideal for land-intensive scenarios such as urban power distribution networks and commercial parks.

  • Three-Phase Balanced Power Supply: Supports three-phase four-wire systems, balancing power and lighting loads with high efficiency and minimal voltage fluctuation.

  • Convenient Maintenance: Centralized top bushing layout eliminates the need for complex opening during 检修 (maintenance), reducing downtime and costs.

  • High Compatibility: Adapts to HV/LV distribution networks, directly connecting to municipal or industrial power systems, and flexibly integrating with grounding compensation equipment.

Main Technical Parameters

Outline Drawing Reference

Reference Photos

Documentation Resource Library
Public.
15kV 20kV 30kV Three Phases Transformer Pad Mounted HV/LV earthing/Grounding distribution transforme
Catalogue
English
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 60000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 60000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Risk Identification and Control Measures for Distribution Transformer Replacement Work
    1.Electric Shock Risk Prevention and ControlAccording to typical design standards for distribution network upgrades, the distance between the transformer’s drop-out fuse and the high-voltage terminal is 1.5 meters. If a crane is used for replacement, it is often impossible to maintain the required minimum safety clearance of 2 meters between the crane boom, lifting gear, slings, wire ropes, and the 10 kV live parts, posing a severe risk of electric shock.Control Measures:Measure 1:De-energize th
    12/25/2025
  • Analysis of Common Faults and Causes in Routine Inspection of Distribution Transformers
    Common Faults and Causes in Routine Inspection of Distribution TransformersAs the terminal component of power transmission and distribution systems, distribution transformers play a critical role in supplying reliable electricity to end users. However, many users have limited knowledge of power equipment, and routine maintenance is often carried out without professional support. If any of the following conditions are observed during transformer operation, immediate action should be taken: Excess
    12/24/2025
  • Analysis of Lightning Protection Measures for Distribution Transformers
    Analysis of Lightning Protection Measures for Distribution TransformersTo prevent lightning surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable lightning protection measures that can effectively enhance their lightning withstand capability.1. Lightning Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvol
    12/24/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.