Description

Description

10MVA Industrial cast-resin pad-mounted transformers are large-capacity, fully enclosed dry-type power distribution devices specifically designed for harsh industrial environments. Their core features include:

  • Cast-Resin Insulation: High-voltage windings use epoxy resin vacuum casting technology, offering full insulation and maintenance-free performance, in compliance with IEC 60076-11 standards.

  • Pad-Mounted Structure: Suitable for outdoor installation, with an IP65 protection rating (dustproof and waterproof), and can be directly placed on concrete foundations.

  • Industrial-Grade Design: Capable of withstanding high-load impacts, harmonic pollution, and extreme climates (operating temperature range: -40°C to +70°C).

Functions, Technical Realization, and Industrial Value

  • Power Conversion: Steps down medium voltage (e.g., 35kV) to industrial power voltage (6.6kV/690V) to meet the power supply requirements of large equipment.

  • Safety Isolation: Adopts an oil-free design (fire rating F1), suitable for inflammable and explosive areas, effectively reducing factory fire risks.

  • Harmonic Suppression: Equipped with an internal aluminum shielding layer, capable of withstanding total harmonic distortion (THD) ≤8% to protect precision industrial equipment from harmonic interference.

  • Overload Capacity: Supports 120% load for 4 consecutive hours and 150% load for 1 hour (in line with IEC 60076-12 standards), addressing peak production loads.

Typical Application Scenarios

Heavy Industry Sector

  • Iron and Steel Metallurgy: Powers arc furnaces, rolling mills, etc., with the ability to withstand frequent short-circuit impacts.

  • Chemical Parks: Adopts anti-corrosion design (316 stainless steel casing) to adapt to corrosive environments with hydrogen sulfide (H₂S), chlorine (Cl₂), etc.

  • Automotive Manufacturing: Used with frequency converter loads, suppressing harmonic interference by configuring 12% reactance rate.

Energy Infrastructure

  • PV/Wind Power Step-Up: Integrates DC component blocking function on the 35kV side, suitable for new energy power generation scenarios.

  • Data Centers: Pursues 99.99% power availability with dual-winding redundancy design.

Special Environments

  • Mining: Features seismic design compliant with EN 60068-3-3 Class 2 standards, adapting to underground vibration environments.

  • Ports: Adopts salt spray protection design, reaching ISO 9227 C5-M grade to resist marine climate erosion.

Parameter:

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 10000m² Total staff: 300 Highest Annual Export(usD): 150000000
Workplace: 10000m²
Total staff: 300
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Substation Maintenance Pressure Plate Operation Guide
    According to the "Eighteen Major Anti-Accident Measures for Power Grid of State Grid Corporation of China (Revised Edition)" promulgated in 2018, operation and maintenance units should improve the on-site operation regulations for intelligent substations, refine the usage instructions and abnormal handling methods for various messages, signals, hard pressure plates, and soft pressure plates of intelligent equipment, standardize the operation sequence of pressure plates, strictly follow the seque
    12/15/2025
  • What Is a Substation Bay? Types & Functions
    A substation bay refers to a complete and independently operable assembly of electrical equipment within a substation. It can be regarded as a fundamental unit of the substation’s electrical system, typically comprising circuit breakers, disconnectors (isolators), earthing switches, instrumentation, protective relays, and other associated devices.The primary function of a substation bay is to receive electrical power from the power system into the substation and then deliver it to the required d
    11/20/2025
  • What is the difference between a pad-mounted substation and a traction substation?
    Pad-Mounted Substation (Box-Type Substation)Definition:A pad-mounted substation, also known as a prefabricated substation or pre-assembled substation, is a compact, factory-assembled power distribution unit that integrates high-voltage switchgear, a distribution transformer, and low-voltage distribution equipment according to a specific wiring scheme. It combines functions such as voltage step-down and low-voltage power distribution into a single unit housed in a fully enclosed, movable steel en
    11/20/2025
  • What Are the Differences Between Substations, Switching Stations, and Distribution Rooms?
    What Are the Differences Between Substations, Switching Stations, and Distribution Rooms?A substation is a power facility in the electric power system that transforms voltage levels, receives and distributes electrical energy, controls the direction of power flow, and adjusts voltage. It interconnects power grids of various voltage levels through its transformers. In specific applications—such as submarine power cables or long-distance transmission—some systems use high-voltage direct current (H
    11/20/2025
  • Application of Maintenance-Free Transformer Breathers in Substations
    Currently, traditional-type breathers are widely used in transformers. The moisture-absorbing capability of silica gel is still judged by operation and maintenance personnel through visual observation of the color change of silica gel beads. Subjective judgment by personnel plays a decisive role. Although it has been clearly stipulated that silica gel in transformer breathers should be replaced when more than two-thirds of it changes color, there is still no accurate quantitative method to deter
    11/18/2025
  • Application of UAV Technology in Sequential Control Operations of Substations
    With the advancement of smart grid technologies, sequential control (SCADA-based automated switching) in substations has become a core technique for ensuring stable power system operation. Although existing sequential control technologies have been widely deployed, challenges related to system stability under complex operating conditions and equipment interoperability remain significant. Unmanned Aerial Vehicle (UAV) technology—characterized by its agility, mobility, and non-contact inspection c
    11/18/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.