• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


10MVA pro usum industrialem transformator funditus-castus in stativa montatus

  • 10MVA Industrial Use Cast-Resin Pad-Mounted Transformer

Attributa principalia

Marca Vziman
Numerus Modeli 10MVA pro usum industrialem transformator funditus-castus in stativa montatus
Tensio primum 33kV
Series ZGS

Descriptiones productorum a fornitori

Descriptio

Descriptio

Transformatores industriales de resina fundida de 10 MVA sunt dispositiva de distributio electrica de capacitate magna, totaliter clausi et sicci, specialiter designati pro ambientibus industrialibus duris. Eorum characteres principales sunt:

  • Insulatio Resinae Funditae: Volvulae altae tensio usant technologiae funditionis vacui epoxy, praebentes insulatio totalem et operationem absque necessitate maintenance, conformiter standardibus IEC 60076-11.
  • Structura Pad-Mounted: Apti ad installationem exteriorem, cum indice protectionis IP65 (impermeabile et antipulvere), et posse collocari directe super fundamenta concreta.
  • Design Industriale: Capaces tolerare impactus magnae oneris, pollutionem harmonica, et climata extrema (amplitude temperaturarum operativarum: -40°C ad +70°C).

Functiones, Realizatio Technica, et Valore Industriale

  • Conversio Potentiae: Reducit tensionem mediam (exempli gratia, 35kV) ad tensionem industrialem (6.6kV/690V) ad satisfaciendas necessitates alimentationis potentiae machinarum magnarum.
  • Isolatio Securitatis: Adoptat design absque oleo (rating ignifugum F1), aptum pro locis inflammabilibus et explosivis, efficaciter minuens pericula incendii in fabricis.
  • Suppressio Harmonicorum: Equipatus cum strato interna alumineo, capax tolerandi distortionem harmonicam totalem (THD) ≤8% ad protegendas machinas industriales precisionis ab interference harmonica.
  • Capacitas Overload: Supportat onus 120% per quattuor horas consecutivas et onus 150% per unam horam (conformiter standardibus IEC 60076-12), solvens onera productionis maxima.

Scenaria Applicationis Typica

Sector Industriae Gravis

  • Metallurgia Ferri et Stanni: Alimentat furnos arcuum, laminarias, etc., cum capacitate tolerantiae impactus circuiti brevis frequentes.
  • Parci Chemici: Adoptat design anti-corrosionis (casus ex aere inox 316) ad adaptandum ad ambientes corrosivos cum hydrido sulfurico (H₂S), chlore (Cl₂), etc.
  • Fabrica Automobilium: Usatur cum oneribus converterum frequentiarum, suppressione interference harmonicarum configurando ratum reactantiae 12%.

Infrastructura Energiae

  • Step-Up PV/Ventus: Integrat functionem blocandi componentem DC in latere 35kV, aptum pro scenariis generationis energiae novae.
  • Data Centers: Consequitur disponibilitatem potentiae 99.99% cum design redundantis volvularum duplex.

Ambientes Specialia

  • Metallurgia: Praeditus design sismico conformiter standardibus EN 60068-3-3 Class 2, adaptans ad vibrationes subterraneas.
  • Portus: Adoptat design protectionis contra salinum, attingens gradum ISO 9227 C5-M ad resistendum erosioni climatis marini.

Parametri:

 

Cognosce tui fornitori
Venditio Online
Ratio praestabilitae tradendae
Tempus responsionis
100.0%
≤4h
Brevis Descriptio Societatis
Locus Operis: 10000m² Numerus omnium laborantium: 300 Summa Annua Exportatio (USD): 150000000
Locus Operis: 10000m²
Numerus omnium laborantium: 300
Summa Annua Exportatio (USD): 150000000
Servitia
Genus Negotii: Design/Fabricatio/Venditio
Categorias Principales: apparatus electrum altum voltus/transformator
Gubernatio vitae
Servitia gestionis curae integralis pro quaestu, usu, conservatione et post-venditionem apparatus electricorum, securitatem operationis, continuationem imperii et usum electricitatis sine cura garantia.
Fornitori instrumentorum praeteritus est certificationem qualificationis platformae et iudicium technicum, ut ex fonte conformitas, professionalitas et fiducia servantur.

Producta Connexa

Cognitio Connexa

  • Accidentia Transformatoris Principalis et Questiones Operationis Gas Luminis
    1. Registri accidentis (XIX Martii, MMXIX)Hora XVI:XIIX die XIX Martii, MMXIX, monitorium background reportavit actionem gas levis transformatoris principis numeri III. Conformiter Codex Operationis Transformatorum Electricitatis (DL/T572-2010), personale operationis et maintenance (O&M) inspectavit statum in situ transformatoris principis numeri III.Confirmatio in situ: Panel non-electricus protectionis WBH transformatoris principis numeri III reportavit actionem gas levis phase B corpus tr
    02/05/2026
  • Culpae et Tractatio Terrae Unipolaris in Lineis Distributionis 10kV
    Characteristica et Instrumenta Detegendi Defectus Terrae Monofasiales1. Characteristica Defectuum Terrae MonofasialiumSigna Centralia Admonitionis:Campanula admonitionis sonat, et lucerna indicativa inscripta „Defectus Terrae in Sectione Omnibus [X] kV [Y]“ accenditur. In systematibus ubi punctum neutrum per bobinam Petersen (bobinam suppressionis arcus) ad terram connectitur, lucerna indicativa „Bobina Petersen Operatur“ etiam accenditur.Indicationes Voltmetri Monitoris Isolationis:Tensio phase
    01/30/2026
  • Modus operationis terre iunctae puncti neutralis pro transformatoribus retis electricitatis 110kV~220kV
    Dispositio modi operis terrae puncti neutralis pro transformatoribus rete electricitatis 110kV~220kV debet exigentias tolerationis insulationis puncti neutralis transformatorum complere, et simul conari ut impedimentum sequentiae nullae stationum transformationis fere immutatum maneat, dum certatur ne impedimentum sequentiae nullae compositum in quocumque puncto raptus circuiti systematis ultra ter impedimentum sequentiae positivae compositum excedat.Pro transformatoribus 220kV et 110kV in novis
    01/29/2026
  • Cur Quare Substationes Lapidem Gravem Calculos et Rupem Fractam Utuntur
    Cur Quare Substationes Utuntur Lapidibus, Gravibus, Piscinis et Saxis Tritis?In stationibus transformationis, instrumenta ut transformatores electricitatis et distributionis, lineae transmissionis, transformatores tensionis, transformatores currentis et commutatores disiunctionis omnia terram exigunt. Praeter terram, nunc profundius explorabimus cur gravia et saxa trita in stationibus transformationis saepe utuntur. Quamquam videantur ordinaria, isti lapides partem criticam iuxtaque functionalem
    01/29/2026
  • Cur autem nucleus transformatoris tantum in uno puncto terram tangere debet Nonne terra multipuncta fidelius est
    Cur ergo nucleus transformatoris terram tangere debet?In operatione, nucleus transformatoris, simul cum structuris, partibus et componentibus metallicis quae fixant nucleum et spiras, in forti campo electrico situs est. Sub influentia huius campi electrici, potentialem relativum altum ad terram comparatum acquirunt. Si nucleus non terra tangitur, differentia potentialis inter nucleum et structuras claudicantes et vas terratum existet, quae possit ad intermitterentiam dismissionem ducere.Praetere
    01/29/2026
  • Intellegere Terram Neutralis Transformatoris
    I. Quid est Punctum Neutrum?In transformatoribus et generatoribus, punctum neutrum est locus specificus in spira ubi absoluta tensio inter hunc locum et singula terminalia externa aequalis est. In diagrammate infra, punctumOrepraesentat punctum neutrum.II. Cur Punctum Neutrum Terrendum Est?Modus connexionis electricae inter punctum neutrum et terram in systemate AC triphasico diciturmodus terrendi puncti neutri. Hic modus directe afficit:Securitatem, fidem et oeconomiciam retelectrici;Selectione
    01/29/2026

Solutiones Relatae

Non invenisti adhuc opportunos fornitoris ut te inveniant Citationem Nunc Accipe
Non invenisti adhuc opportunos fornitoris ut te inveniant
Citationem Nunc Accipe
Inquiry
+86
Click to upload file
Descarica
Obtine Applicatio Commerciale IEE-Business
Utiliza app IEE-Business ad inveniendum apparatus obtinendumque solutiones coniungendum cum peritis et participandum in collaboratione industriale ubique et semper propter totam supportionem tuorum projectorum electricitatis et negotiorum