0 to 600Hz Special frequency converter for lifting

  • 0 to 600Hz Special frequency converter for lifting

Key attributes

Brand RW Energy
Model NO. 0 to 600Hz Special frequency converter for lifting
Rated frequency 50/60Hz
Series HV610

Product descriptions from the supplier

Description

Overview

In order to better meet the application needs of customers in the lifting industry, the product is based on the perspective of lifting application, integrating anti-sway control, anti-loosening rope protection, slip hook protection, brake control, deceleration limit, speed with load, macro parameters and other special functions, fully ensuring the reliable, efficient, safe and stable operation of lifting equipment.

Performance characteristics

Specialize in characteristics

  • Anti-sway control, suppressing spreader swing and efficient operation

  • Adjusting the running speed in real time according to the load change with the load of the load • Hook protection, brake detection hook, control motor output hover

  • Easy positioning through deceleration limit and stop limit cooperation

  • Anti-loosening rope protection, going up at a fixed speed, slowly accelerating and rising smoothly when detecting heavy

  • The corresponding lifting mechanism can be selected according to the macro setting value of the lifting parameters

  • Multi-motor switching, and 4 sets of motor parameters are supported internally.

High reliability

  • Independent air duct design of the whole machine to effectively prevent dust impurities from entering • Efficient and accurate thermal simulation platform software

  • Advanced thermal testing and verification technology and devices to effectively verify the theoretical results of thermal design

  • Rigorous full load and overload verification test procedures

  • Products have been aged at high temperature and load, effectively ensuring factory quality

  • Circuit board protection is strengthened design, anti-corrosion, moisture-proof, dustproof, etc

High adaptability

  • Wide voltage range design, three-phase 380V~480V (-15%~+10%)

  • Built-in C3 filter, effectively suppressing the high-frequency harmonics generated by the frequency converter

  • Simple and friendly EMC ground break design, which can effectively reduce the leakage current to the floor

  • Book-type design, which reduces the volume of the traditional model by about 40%

  • The whole machine can be installed side by side to save installation space.

Excellent performance control

  • Support drive control of three-phase asynchronous motor and permanent magnet synchronous motor

  • Support V/F control, open-loop vectoring, closed-loop vector control

  • Large starting torque, OLVC: 0.5Hz/150%, CLVC: 0Hz/200%

  • High overload capacity, 150% rated current 60s, 180% rated current 10s

Convenient and easy to use

  • 132kW and above standard machine factory equipped with LED keypad can support external introduction

  • 110kW and below keyboard external introduction can be equipped with independent LED keyboard

  • When the frequency converter starts and stops, the motor can be controlled by holding the brake • Multi-speed control function, which realizes 16-speed operation through the control terminal

  • Zero servo function, the motor

  • Random PWM depth to improve motor harshness

  • Encoder redundant operation mode that automatically switches to OLVC operation when encoder fails

Expand diversification

  • Support a variety of code disk interface cards、Support I/O terminal expansion cards

  • Support Profibus-DP, Profinet IO, CANopen, Modbus-TCP/IP, EtherNet IP, Ethercat and other communications

  • Autonomous and rapid commissioning

  •  

    Support connection to background software, making debugging and maintenance more convenient

  • Support event recording and fault recording

 

Main parameters

project

Specifications and technical data

Power input and output

Input voltage

380V(-15%)~480V(+10%) three-phase

Input power frequency

50Hz/60Hz ±5%

Input voltage imbalance

≤3%

Output voltage

0V~input voltage

Output frequency

0~600Hz

Mainly control performance

Motor type

Asynchronous motor, synchronous motor

Control mode

V/F, OLVC (Open-Loop Vector Control), CLVC (Closed-Loop Vector Control)

speed regulation range

1:10 V/F; 1:100 OLVC; 1:1000 CLVC

Start torque

OLVC:150%(0.5Hz);CLVC:200%(0Hz)

Torque accuracy

≤ ±5%, under vector control mode

Torque pulsation

≤ ±5%, under vector control mode

Steady speed accuracy

OLVC: 0.2%; CLVC :0.01%

Torque response

≤5ms, under vector control

acceleration and deceleration time

0.0s~3200.0s;0.0min~3200.0min

Torque increase

0.0%~30.0%

Overload capacity

150%1min/5min、180%10s/5min

VF curve

Straight type, multi-point type

Input frequency resolution

Digital setting 0.01Hz; Analog setting: Maximum frequency x 0.025%

Dedicated features

Anti-shake function

Prevents accidents caused by large swings of the load during acceleration or deceleration

Anti-loose rope protection

Accelerate slowly and rise smoothly according to whether the weight is lifted

Hook protection

After holding the gate, it detects whether the heavy object is hooked, and an alarm is issued, and the motor hovers

Holding the brake control

Control the brake holding device and loosening the brake through the judgment of frequency, current, etc., to avoid accidents such as slipping

Joystick zeroing detection

Determine whether the joystick is in neutral or not

Command reverse control

When the brake control is effective, it supports holding the brake to stop during the forward and reverse switching process, or running directly to the reversal frequency without holding the brake

Accelerate and deceleration switching

Support 3 frequency switching points to switch acceleration and deceleration time

Deceleration limit

Realize simple positioning function, automatic optimization of deceleration time

Voltage suppression

Automatically change the frequency to stabilize the bus voltage to prevent fault reporting

Overload protection

Prevents excessive loads from damaging the equipment

Low-speed operation protection

The main application is not suitable for machines that run at low speed for a long time

Load as you go

Automatically adjust the operating speed according to load changes to improve work efficiency

Macro parameters

According to the on-site application scenario, different lifting mechanisms choose different lifting macros

Basic features:

acceleration and deceleration curves

Straight line, S-curve

Simple PLC, multi-terminal speed

16 speed operation is achieved through the control terminal

Master-slave control

It can realize the master-slave synchronous control function of two or more motors

Automatic voltage adjustment

When the grid voltage changes within a certain range, it can automatically keep the output voltage constant

Multi-motor switching

Four sets of motor parameters, which can realize the switching control of four motors

Overvoltage and overcurrent stall control

Automatic current and voltage limit during operation to prevent frequent overcurrent and overvoltage tripping

Power outage and restart

After the frequency converter is powered off, when it is powered on again, it will automatically run after the set time is reached

Fast current throttling

Avoid frequent overcurrent failures of the frequency converter

Power input and output

Frequency setting method

Operation panel given, UP/DOWN terminal, multi-speed give, terminal pulse given, communication

Analog input terminals

AI1、AI2:0V~10V/ 0 (4)mA~20mA

Digital input terminals

DI1-DI5, 5 programmable digital inputs, optocoupler-isolated, drain/source compatible inputs

The DI5 supports high-speed pulse input with a maximum input frequency of 100kHz

Digital output terminals

open-circuit collector output; Output Voltage Range: 0V~24V; Current load capacity: 50mA

DO1 supports high-speed pulse output, maximum output frequency: 100kHz

Analog output terminals

1 way 0V~10V/0(4)mA~20mA

Relay output

1 contact type: FormC normally open + normally closed

communication

Communication protocol

Modbus RTU (standard); Profibus-DP, Profinet IO, CANopen, Modbus TCP/IP, Ethercat, EtherNet/IP (optional)

Usage environment

altitude

no derating is required within 1000 meters above sea level; At an altitude of 1000 meters ~ 3000 meters, the current must be reduced by 1% for every 100 meters of elevation

Ambient temperature

-25°C~+40°C (40°C to 55°C derating is allowed)

humidity

15%~95%, no condensation

vibration

0.75~110kW is the 3M3 standard, 2Hz≤F<9Hz, displacement 1.5mm, 9Hz≤f<200Hz, acceleration 5m/s2

132kW~400kW is the 3M5 standard, 2Hz≤F<9Hz, displacement 3mm, 9Hz≤f<200Hz, acceleration 10m/s2

Storage temperature

-40°C~+70°C

Place of use

Indoors, there is no direct sunlight, no flammable and corrosive gases, liquids and conductive particles

Options:

code disk card, communication expansion card, I/O terminal expansion card

Protection function

Short circuit, overcurrent, overload, overvoltage, undervoltage, phase loss, overheating, external faults, etc

Installation method:

Loading machines and containers

Protection level

IP20

Cooling method

Air cooling

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.