fahrenquineri qaylumneri veradarcnumqagits testeri ankyunqner
1. Porcelain-an chapsarayin qaylumneri testeri
1.1 Isolatsia tarazmeri
Qaylumy kranen yoki stantdan arajin chkaqerqan vertikalakan. Isolatsia tarazmeri mianginek chkaqerqan hamar petqenqic (tap/flange) 2500V isolatsia tarazmeri aparatum en. Ankyunqneq hetoq hogebatvac petqani tseghavor petqani ankyunqneri mejy nerkayel eq meji karox. 66kV yev mec en liniayin qaylumneri voronkayin petqanum en, petqani yev flange isolatsia tarazmeri ankyunqneri 2500V isolatsia tarazmeri aparatum en; ankyunqy petqe 1000MΩ.
Dissipation factor (tanδ) yev kapasitansi ankyunqneri mianginek tap petqenqic positiv wiring method-om en. Aparatume naxordnelu wiring konfiguratsian yev 10kV testi baycvox en.
Dissipation factor ankyunqneri uchun high-voltage test leads-n inqnorvel insulating tape-n en, bardzrakal banakeri yev erkuvi xndir. Lrakvor hraparakneri ankyunqneri noravor petqani tesnakutyan gorcoxutyune. Ankyunqneq dissipation factor yev kapasitans hetoq hogebatvac petqani ankyunqneri mejy nerkayel eq meji karox yev handover standards-i mijacvel.
2. On-Load Tap Changer Inspection and Testing
On-load tap changer contacts-in polorakankum action sequence-in patkan. Transition resistance value yev switching time ankyunqneri mianginek. Ankyunqneq transition resistance values, three-phase synchronization deviation, switching time values, yev forward-reverse switching time deviation manufacturer's technical requirements-i mijacvel.
3. DC Resistance Measurement of Windings with Bushings
High-voltage winding-in tap position-yi yev low-voltage side-in DC resistance ankyunqneri mianginek. Neutral points en transformers-in single-phase DC resistance ankyunqneri. Ankyunqneri mijacvel ambient temperature en, factory values-i temparaturi konvertovum en. Line-to-line yev phase-to-phase values-i ankyunqneri handover standards-i mijacvel.
4. Voltage Ratio Check for All Tap Positions
Turns ratio tester leads-n high yev low voltage sides-in three-phase transformer-e mianginek. Voltage ratio ankyunqneri mianginek all tap positions-in. Manufacturer's nameplate data-in petqaneq hogebatvac ankyunqneri mejy nerkayel eq meji karox, ratios expected patterns-i mijacvel. Rated tap position-in allowable error ±0.5%. Three-winding transformers-in HV-MV, MV-LV ratio tests perform.
5. Check Three-Phase Connection Group and Single-Phase Transformer Terminal Polarity
Verification results design requirements, nameplate markings, yev symbols transformer housing-e mijacvel.
6. Insulation Oil Sampling and Testing
Oil sampling transformer completely filled oil yev allowed stand specified time. Oil sample collected, container properly sealed, promptly delivered relevant department testing.
7. Insulation Resistance, Absorption Ratio or Polarization Index Measurement
All insulation-related tests insulating oil passed inspection, weather conditions appropriate humidity levels. Transformers requiring polarization index measurement, verify short-circuit current insulation resistance meter not less than 2mA. Record ambient temperature testing, facilitate comparison factory values equivalent temperatures. Measured values not less than 70% factory values. Test items include: HV-(MV+LV+ground), MV-(HV+LV+ground), LV-(MV+HV+ground), overall-ground, core-(clamp+ground), clamp-(core+ground). For example, HV-(MV+LV+ground), short-circuit all three phases high-voltage side corresponding neutral point (if present), ground all other parts, connect high-voltage terminal insulation resistance meter HV side, ground terminal to ground testing.
8. Measurement of Dissipation Factor (tanδ) for Windings with Bushings
Test reverse wiring method, instrument's specified wiring configuration. Test items include: HV-(MV+LV+ground), MV-(HV+LV+ground), LV-(MV+HV+ground), overall-ground, performed sequentially. Testing, suspend high-voltage test leads dissipation factor tester insulating tape, prevent contact transformer tank. Record ambient temperature testing. Comparing factory values equivalent temperatures, measured values not exceed 1.3 times factory values. Measurements deviate significantly factory values, clean bushings use conductive shielding bushings reduce surface leakage current. Testing preferably conducted weather relatively low humidity.
9. DC Leakage Current Measurement for Windings with Bushings
Արտահոսքի հոսանքը պետք է չափվի բարձր լարման կողմուց։ Ստուգումները ներառում են. ԲԼ-(ՄԼ+ՓԼ+դաշտ), ՄԼ-(ԲԼ+ՓԼ+դաշտ), ՓԼ-(ՄԼ+ԲԼ+դաշտ)։ Ստուգումը պետք է կատարվի ցածր 습도յի մեջ և պետք է գրանցվի շրջապատական ջերմունակությունը։ Արտահոսքի հոսանքի արժեքը չպետք է գերազանցի սեղման ստանդարտներում նշված սպեկտական նախագծմանը։
10. Էլեկտրական ստուգումներ
10.1 Սպիրալի դեֆորմացիայի ստուգում
35կՎ և ներքև կարգավորված ձեռնարկների համար առաջարկվում է օգտագործել ցածր լարման կորուստային իմպեդանսի մեթոդը։ 66կՎ-ից և վեր կարգավորված ձեռնարկների համար առաջարկվում է օգտագործել հաճախականության պատասխանային վերլուծության (FRA) մեթոդը սպիրալի բնութագրական սպեկտրի չափման համար։
10.2 Ալիքային կարողանալու ստուգում
Կատարեք ալիքային կարողանալու ստուգումներ ձեռնարկի կողմնային կետերում՝ օգտագործելով արտաքին կիրառված էլեկտրա լարման կամ առաջացված լարման մեթոդները։ Եթե հնարավոր է, օգտագործեք հաջորդական ռեզոնանսի առաջացված լարման ստուգումը ստուգման սարքավորումների ներկայացման նվազեցման համար։ 110կՎ-ից և վեր կարգավորված ձեռնարկների համար առաջարկվում է ներկայացնել առանձին ալիքային կարողանալու ստուգում նեյտրալ կետի համար։ Ստուգման լարման արժեքները պետք է հետևեն սեղման ստանդարտներին։
10.3 .getLong-Time Induced Voltage Test with Partial Discharge Measurement
220կՎ-ից և վեր կարգավորված ձեռնարկների համար նոր տեղադրման ժամանակ դաշտում պետք է կատարվի կարգավորված առաջացված լարման ստուգումներ մասնակի արտահոսքի չափման հետ։ 110կՎ ձեռնարկների համար, երբ կարգավորված կարգավորումը նշանակալի է, առաջարկվում է կատարել մասնակի արտահոսքի ստուգում։ Այս ստուգումները հայտնաբերում են ձեռնարկներում չկայուն ներքին կարգավորումների կենտրոնացած արտահոսքի սխալները։
10.4 Նոր տեղադրման պլանի պահանջներին համապատասխան կատարեք նոր տեղադրման ժամանակ լրիվ լարման իմպուլսային փակումը նշված լարման վրա։
10.5 Ֆազայի ստուգում
Ստուգեք ձեռնարկի ֆազայի հաջորդականությունը, որը պետք է համընկնի ցանցի ֆազայի հաջորդականության հետ։
Յուրաքանչյուր կարգավորումի համար դաշտի բացասական ջերմունակության ժամանակ հատուկ ուշադրություն է պետք դարձնել մասլի հատկություններին։ Օրինակ, գլխավոր ամբողջական մասլու համար բացասական ջերմունակության դեպքում մասլի խիթրությունը ավելի բարձր է, ինչը առաջ է բերում վատ հոսանքի հոսքի և ջերմության հեռացման։ Բացասական ջերմունակության դեպքում բեռնավորման կետերի փոփոխման կոմպարտման մասլու համար կարող է երկարացնել փոփոխման գործընթացը և ավելացնել առանցքային դիմադրության ջերմության աճը։
ԷՀՎ մասլային ձեռնարկների գլխավոր ամբողջական մասլու համակարգի համար նաև պետք է դարձնել ուշադրություն մասլի հոսանքի էլեկտրավանացման երևույթին։ Անհրաժեշտ է կանխարձակալություն առնել մասլի հոսանքի էլեկտրավանացմանից մասլի հոսանքի էլեկտրավանացման անցնելու միջոցով կառավարելով մասլի դիմադրությունը, մասլի հոսանքի արագությունը տարբեր մասերում և առաջացնելով բավարար տարածություն էլեկտրա լարման ազատման համար մասլու մեջ։