What is the reason for using delta-delta connections in power transmission lines instead of other combinations?

Encyclopedia
Field: Encyclopedia
0
China

Voltage Aspect

In a delta connection, the line voltage is equal to the phase voltage. This characteristic makes the delta connection widely used in high and medium voltage areas for power transmission in situations where higher voltages are required, as it can directly utilize the line voltage for power transmission without the need for additional voltage conversion operations, which helps reduce energy losses during the voltage conversion process.

For example, in a delta-connected three-phase load, each phase load is connected directly between two phase lines, and the load's phase voltage is the same as the line voltage of the power source (grid). This means that when a three-phase motor is connected in a delta configuration, each winding can withstand the line voltage (380V), whereas in a star connection, each winding of the motor bears the phase voltage (220V). For devices requiring high voltage, a delta connection is more advantageous.

Load Capacity Aspect

The increase in the number of nodes in a delta connection does not affect the power supply's load capacity, and in some cases, each winding in a delta connection has more power than the windings in a star connection, which allows the system to withstand greater loads and transmit more electrical energy in transmission lines.

The performance of triangle connection in stability compared to other connection methods

Voltage Stability

In a delta connection of three-phase power, even if one winding is short-circuited, the voltage of the other windings will not change significantly, and the voltage is relatively stable. In contrast, in a star connection, if one winding is short-circuited, the voltage of the other windings will quickly increase, which may affect the stable operation of the transmission line.

Electric Energy Balance Stability

The delta connection of a three-phase load can achieve rapid electrical energy balancing, making power transmission more stable and providing users with more efficient power supply, reducing issues such as fluctuations caused by energy imbalance.

Impact of Triangle Connection on Transmission Efficiency

Reduce line loss

Triangular connections can effectively reduce power outages, thereby indirectly improving transmission efficiency. The reduction in the number of power outages means better continuity of power supply, reducing energy losses caused by restarting equipment and readjusting power distribution due to power outages. Moreover, triangular connections can balance the load, thereby reducing losses during transmission and providing continuous and effective power services to users, improving the overall efficiency of the transmission line.

Characteristics of Triangle Connection in Fault Response

Fault Current Limiting Aspects

In a transformer delta connection, when one phase fails, the fault current will flow into the other two phases. Because this type of connection is not easy to generate residual current, in some cases, it can provide better fault current limitation compared to other connection methods. However, it should be noted that when a single-phase short circuit occurs in a delta connection, the short-circuit current can exceed many times the rated current of the capacitor, which can easily lead to the expansion of the accident.

Reliability Aspect

The delta connection of a three-phase load can prevent the system from overloading or short-circuiting, effectively improving the reliability of the power system. This is very important for transmission lines, as it can ensure the safety and stability of the transmission process, reducing issues such as transmission interruptions caused by faults.

Give a tip and encourage the author!

Recommended

Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.