What is Static Relay ?

Edwiin
Field: Power switch
China

What is Static Relay ?

Definition: A relay that has no moving parts is referred to as a static relay. In this type of relay, the output is generated by static components such as magnetic and electronic circuits. Even if a relay combines static elements with an electromagnetic relay, it is still called a static relay. This is because the static units are responsible for sensing the input and generating a response, while the electromagnetic relay is merely utilized for the switching operation.

The components of a static relay are depicted in the figure below. The input of the current transformer is connected to the transmission line, and its output is fed to the rectifier. The rectifier rectifies the input signal and forwards it to the relaying measuring unit.

The rectifying measuring unit consists of comparators, a level detector, and a logic circuit. The output signal from the relaying unit is obtained only when the input signal reaches the threshold value. The output of the relaying measuring unit serves as the input to the amplifier.

The amplifier magnifies the signal and provides the output to the output devices. The output device activates the trip coil only when the relay is in operation. The output is derived from the output devices only when the measurand has a well - defined value. Once activated, the output device issues a tripping command to the trip circuit.

Static relays respond solely to electrical signals. Other physical quantities such as heat, temperature, etc., need to be first converted into analogue or digital electrical signals before being used as inputs for the relay.

Advantages of Static Relay

The following are the advantages of static relays:

  • Static relays consume very little power. As a result, the burden on measuring instruments is reduced, and their accuracy is enhanced.

  • They offer a quick response, long lifespan, high reliability, high accuracy, and are shockproof.

  • The reset time of the relay is extremely short.

  • There are no thermal storage issues associated with them.

  • The relay amplifies the input signal, which increases its sensitivity.

  • The likelihood of unwanted tripping is low.

  • Static relays can operate easily in earthquake - prone areas due to their high shock resistance.

Limitations of Static Relay

  • The components used in static relays are highly sensitive to electrostatic discharges. Electrostatic discharges refer to the sudden flow of electrons between charged objects. Hence, special maintenance measures must be implemented for the components to prevent them from being affected by electrostatic discharges.

  • The relay is vulnerable to high - voltage surges. Therefore, precautions should be taken to avoid damage from voltage spikes.

  • The operation of the relay depends on electrical components.

  • It has a relatively low overloading capacity.

  • Static relays are more expensive compared to electromagnetic relays.

  • The construction of the relay is easily influenced by surrounding interference.

For integrated protection and monitoring systems, programmable microprocessor - controlled static relays are preferred.

Give a tip and encourage the author!

Recommended

Main Transformer Accidents and Light Gas Operation Issues
1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
02/05/2026
Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
01/30/2026
Neutral point grounding operation mode for 110kV~220kV power grid transformers
The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
01/29/2026
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
01/29/2026
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.