What is the method for measuring point-to-point voltage drop?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

The methods for measuring the voltage drop between two points mainly include using a multimeter and a stable current power supply.

Equipment Preparation

You need to prepare a digital multimeter and a stable current power supply.

  • Ensure that the device is turned off and correctly connected to the output end of the current source.

Measurement Steps

Connect the positive probe of the multimeter to the positive terminal of the wire being tested, and the negative probe to the negative terminal.

Ensure that the test probe makes good contact with the test point, and the component under test is in operation.

Open the constant current power supply, adjust it to the required current value, and then turn on the voltage output.

Record the reading on the multimeter, which is the measured voltage drop value.

Notes

  • During the measurement process, minimize the relative motion of the measured sample to avoid affecting the measurement value.

To maintain the repeatability of measurements, care should be taken to avoid interference from external factors such as drafts and high-frequency radiation.

Calculation and Determination

  • Based on the measurement results, the voltage drop at the wire crimping point can be calculated, usually by comparing the voltage drop values at different measuring points.

  • The criteria for judgment can refer to relevant industry standards or specifications, such as USCAR21.

By following the above steps, you can accurately measure the voltage drop between two points, providing a basis for circuit analysis and fault diagnosis.


Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.