Key Design Considerations for Enhancing Power Transformer Reliability

Vziman
Vziman
Field: Manufacturing
China

Power transformers are critical components within the power grid. Once quality issues occur, they may not only result in significant economic and property losses but also endanger lives and cause immeasurable negative social impacts.

Generally, the reliability of a power transformer is primarily influenced by its design, technology, materials, and manufacturing standards. Among these, design—being the foundation of product quality—plays a crucial role in determining the overall reliability of power transformers.

Statistics indicate that "design defects" are the primary cause of major quality incidents historically experienced by the industry, accounting for over 80% of such events. Therefore, the reliability of transformer design is both a prerequisite and a fundamental guarantee for achieving overall product reliability. This article discusses several key aspects of transformer reliability design.

Short-Circuit Withstand Capability Design Principle

Short-circuit withstand capability is a key indicator of power transformer reliability. Damage due to insufficient short-circuit strength is not uncommon in power systems, and failures during random short-circuit tests are also frequently reported.

As a special test, only a very small proportion of power transformers—less than 1% of total production—undergo actual short-circuit testing. Hence, design validation remains the most practical approach to ensure adequate short-circuit withstand capability.

The fundamental principle of short-circuit design should focus on minimizing the actual short-circuit stress as much as possible, rather than blindly increasing the allowable stress limits. The latter approach overly depends on material properties and manufacturing processes and represents an uncontrollable design strategy.

Design Considerations for Hot Spot Temperature Rise

The hot spot temperature rise in various components of a power transformer is closely linked to its service life and directly affects long-term operational reliability. As a type test, temperature rise testing is not performed on every unit. Thus, design analysis and verification remain essential to ensure that hot spot temperature rises across all components remain within safe limits.

Transformer hot spot temperature rise design should focus on three critical areas: winding hot spots, core hot spots, and hot spots in metallic structural parts. Accurate calculation of leakage magnetic field distribution and loss density, based on product structure and parameters, provides a vital foundation for the rational selection of component materials, effective implementation of stray flux control measures, and optimized cooling oil circuit design—ensuring that all component hot spot temperature rises remain within safe values.

Give a tip and encourage the author!
Recommended
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Basic Composition and Function of Circuit Breaker Failure ProtectionCircuit breaker failure protection refers to a protective scheme that operates when the relay protection of a faulty electrical device issues a trip command but the circuit breaker fails to operate. It uses the protection trip signal from the faulty equipment and the current measurement from the failed breaker to determine breaker failure. The protection can then isolate other relevant breakers within the same substation in a sh
Felix Spark
10/28/2025
 Electrical Room Power-On Safety Operation Guide
Electrical Room Power-On Safety Operation Guide
Power Supply Procedure for Low-Voltage Electrical RoomsI. Pre-Power-On Preparations Clean the electrical room thoroughly; remove all debris from switchgear and transformers, and secure all covers. Inspect busbars and cable connections inside transformers and switchgear; ensure all screws are tightened. Live parts must maintain adequate safety clearance from cabinet enclosures and between phases. Test all safety equipment before energizing; use only calibrated measuring instruments. Prepare fire-
Echo
10/28/2025
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
1 Key Points in Operation of High and Low Voltage Equipment1.1 High and Low Voltage EquipmentInspect insulating porcelain components for dirt, damage, or signs of electrical discharge. Check the exterior of low-voltage capacitor compensators for excessive temperature or bulging. If both conditions occur simultaneously, suspend installation work immediately. Examine wiring and terminal joints for oil leakage and conduct a thorough inspection for potential issues.Use auditory judgment to assess th
Felix Spark
10/28/2025