Electrical Room Power-On Safety Operation Guide

Echo
Echo
Field: Transformer Analysis
China

Power Supply Procedure for Low-Voltage Electrical Rooms

I. Pre-Power-On Preparations

  • Clean the electrical room thoroughly; remove all debris from switchgear and transformers, and secure all covers.

  • Inspect busbars and cable connections inside transformers and switchgear; ensure all screws are tightened. Live parts must maintain adequate safety clearance from cabinet enclosures and between phases.

  • Test all safety equipment before energizing; use only calibrated measuring instruments. Prepare fire-fighting equipment and necessary warning signs (e.g., "Danger", "Do Not Close").

  • Verify that grounding and bonding systems are intact and reliable.

  • Check secondary wiring in switchgear for correctness and ensure all terminals are securely tightened.

  • Set protective relay settings for all equipment according to the electrical system drawings.

II. Power-On Procedure

  • Open the grounding switch of the transformer cubicle in the 10kV switchroom, then insert the circuit breaker trolley into position.

  • Close the load switch in the high-voltage incoming line isolation cubicle.

  • Press the transformer closing button to perform five inrush energizations, with a 5-minute interval between each.

  • Sequentially insert and close each low-voltage switchgear drawer unit. Use a multimeter to verify normal voltage and confirm no abnormalities in all low-voltage cabinets.

  • After all equipment is energized, operate under load for 24 hours for observation and testing.

Give a tip and encourage the author!
Recommended
Complete Guide to Circuit Breaker Selection and Setting Calculation
Complete Guide to Circuit Breaker Selection and Setting Calculation
How to Select and Set Circuit Breakers1. Types of Circuit Breakers1.1 Air Circuit Breaker (ACB)Also known as a molded frame or universal circuit breaker, all components are mounted within an insulated metal frame. It is typically open-type, allowing easy replacement of contacts and parts, and can be equipped with various accessories. ACBs are commonly used as main power supply switches. Overcurrent trip units include electromagnetic, electronic, and intelligent types. They provide four-stage pro
Echo
10/28/2025
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Operation and Fault Handling of High and Low Voltage Power Distribution Systems
Basic Composition and Function of Circuit Breaker Failure ProtectionCircuit breaker failure protection refers to a protective scheme that operates when the relay protection of a faulty electrical device issues a trip command but the circuit breaker fails to operate. It uses the protection trip signal from the faulty equipment and the current measurement from the failed breaker to determine breaker failure. The protection can then isolate other relevant breakers within the same substation in a sh
Felix Spark
10/28/2025
How to improve the operational efficiency and safety of low-voltage distribution networks?
How to improve the operational efficiency and safety of low-voltage distribution networks?
Optimization and Key Considerations for Operation and Maintenance Management of Low-Voltage Distribution NetworksWith the rapid development of China's power industry, operation and maintenance (O&M) management of low-voltage distribution networks has become increasingly important. A low-voltage distribution network refers to the power supply lines between a power transformer and end-user equipment, forming the most fundamental and critical part of the power system. To ensure its normal opera
Encyclopedia
10/28/2025
Low-Voltage Distribution Cabinet Maintenance Steps and Safety Guide
Low-Voltage Distribution Cabinet Maintenance Steps and Safety Guide
Maintenance Procedure for Low-Voltage Power Distribution FacilitiesLow-voltage power distr ibution facilities refer to the infrastructure that delivers electrical power from a power supply room to end-user equipment, typically including distribution cabinets, cables, and wiring. To ensure the normal operation of these facilities and guarantee user safety and power supply quality, regular maintenance and servicing are essential. This article provides a detailed introduction to the maintenance pro
Edwiin
10/28/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.