چه پرۆسێسێک هەیە بۆ پیویستکردنی کۆنڤێرتری AC/DC بۆ مۆتۆرێکی سێ فازی

Encyclopedia
qalab: Ençiklopedia
0
China

I. Pêşpeyvên Sêdeme

(1) Bînin bêje di motoreya sêdimek û convertera AC/DC de

Motoreya sêdimek

Motoreyên sêdimek hene pêşve û rengi delta. Pêşveka x, y û z bi daweyên sê setan de windings tê gotin, li ser cihê rêkezê nûsreyek neutral da çêkirin, û sê xettan ji berê din windings tê gotin bi A, b û c hatine çêkirin, ku sistemê sêdimek û sê xetê were form kirin; rengi delta li ser cihê rêkezê nûsreya power supply an load bi rastîne, bê nûsreyek neutral, ku sistemê sêdimek û sê xetê ye, bi xetek ground û sêdimek û sê xetê were form kirin. Rengên din werin biguherînin operaçonên motore, ji ber vê lê zorik e ku li pir wek rengê motore ya bike tevlê bikin lê zelbike convertera AC/DC.

Convertera AC/DC

Convertera AC/DC element ek e ku bihêza alternating current voltage bibêje direct current voltage. Metodên çend ên common in transformer method û switch method. Transformer method di navbera dike alternating current voltage bi transformer bike, bi diode bridge rectifier full-wave rectify bike, û bi capacitor output direct current voltage smooth bike; switch method dike diode bridge rectification, capacitor smoothing, bi ON/OFF switch elements direct current voltage chop bike, û bi operations û voltage reduction bi high-frequency transformer, bi feedback control bihêza stable direct current output.

(II) Parameters Equipment dikirin

Parameters Motoreya Sêdimek

Zorik e ku parameters rated voltage, rated power, rated current û dinan parameters motoreya sêdimek dikirin. Mînwe, rated voltage baseyek important e ku bihêza output direct current voltage convertera AC/DC bêtir bike. Ji ber vê yekem, ger rated voltage motore 380V (alternating current voltage sêdimek) be, ewa output direct current voltage convertera AC/DC divê requirements start-up û operaçon motore bêtir bike.

Parameters Convertera AC/DC

Zorik e ku input voltage range convertera AC/DC (mînwe line voltage range ji bo input three-phase AC), output voltage, output current û dinan parameters dikirin. Mînwe, output voltage divê match be rated voltage motoreya sêdimek, û output current divê running current requirements motore bêtir bike.

II. Steps Connection

(1) Connect three-phase power to the AC/DC converter

Three-phase Power Terminal

Ji bo three-phase four-wire power supply, bêrîn bêtir bixin lêser L1, L2, L3 û neutral line (N). Ji bo three-phase three-wire power supply, tenê sê phase lines hene.

AC/DC Converter Input

Li ser wiring labels convertera AC/DC, connect phase lines three-phase power supply to three-phase input terminals convertera AC/DC. Hin convertera AC/DC dibayê specific phase sequence connections, ji ber vê piştre manual device bikin.

(II) Connect the AC/DC converter to the three-phase motor.

AC/DC Converter Output

Determine positive û negative terminals DC output convertera AC/DC.

Three-phase Motor Connection

Connect positive terminal DC output convertera AC/DC to one end of winding three-phase motor (mînwe, starting end A-phase winding), û negative terminal to other end that winding or to common terminal motor (if available). Ji bo multi-winding motor, connect other windings to output terminals convertera AC/DC in sequence according to motor's wiring diagram û design requirements.

III. Inspection after Connection

(I) Check for Firm Connection

  • Check all connecting wires from three-phase power to AC/DC converter and from AC/DC converter to three-phase motor to ensure they are firmly connected û there are no loose terminal connections.

  • Check if connections at wire joints are tightened to avoid overheating û sparking due to poor contact.

(II) Electrical Parameter Inspection

  • Use measuring tools such as multimeters to check if input voltage AC/DC converter is within normal range û whether three-phase voltages are balanced.

  • Measure output direct current voltage AC/DC converter to ensure it meets requirements three-phase motor, û check for short circuits û open circuits in output.

(III) Equipment Start-up Test

After ensuring previous inspection is correct, power on AC/DC converter first, observe its working status, such as whether indicator lights are normally lit, whether there are alarm sounds, etc.

Then start three-phase motor û observe its operation, including whether it starts normally, whether there are abnormal vibrations û noises during operation, etc. If any abnormality found, immediately stop equipment û re-check connections û equipment parameters.


Bexşişek bidin û nuşkarê wê bikevin!​

Pêşniyariyek

Transformatorê Yekêm û Pirsgirêkek Daqiqên Gazê Bêdar a IEE-Business
1. Peyda Qazaya (Març 19, 2019)Bêya 16:13 di roja Març 19, 2019 de, sistemê pîştimariyê rapor ên birayên gasê hêla leh bû yên transformatora sereke ya numarê 3. Li ser amadeya Qaytandina Operasyonê ya Transformatoran (DL/T572-2010), karkirên operasyon û mînguha (O&M) şertê ji herêmekê yên transformatora sereke ya numarê 3 kontrol kir.Teyit ji herêmekê: Panela WBH paqijeyê nelektrîk nayê yên transformatora sereke ya numarê 3 birayên gasê hêla leh bû yên fîlana B reyazkir û vegera niha rêvekir
02/05/2026
Xalakên û Pêşkêşkirina Yekfîlan Dihênan da Tirazên 10kV
Taybetmendiyên şiklê xwezayî û amûrên vedibijêrin şiklê xwezayî ya yek-fazê ya li ser zemîn1. Taybetmendiyên şiklê xwezayî ya yek-fazê ya li ser zemînÎşaretên alarmê yên navendî:Zilê alarmê dide, û çirka ku bi "Şiklê xwezayî ya li ser zemîn li ser kablî ya [X] kV ya beşa [Y] ya bus" tê nîşankirin dike. Li sistemên ku li ser zemîn bi kûlîka Petersen (kûlîka rûniştkirinê ya arkê) hatiye çêkirin, çirka "Kûlîka Petersen kar dike" jî dike.Nîşanên voltmetreya kontrolkirina îzolasyonê:Voltajê ya fazê y
01/30/2026
Moda operasyonî da vengkirina dîmenê ji bo transformatorên şebê elektrik 110kV~220kV
Cihêna girîngkirina wêje nötr da ji bo dawereyên elektrik 110kV~220kV divê bixebitandina nişanên dijla wekheviya cihêna nötr yên transformatoran biguheze û hewce bike ku impedaansa sifiriyê ya stasyonên transformasyonê tevahî neqdar bike. Heta duayin dikare ku impedaansa sifiriyê yekbûyî ya her çendkêjiyê yên sisteman jêr be trehê ji impedaansa birinî yekbûyî neqde.Ji bo transformatoran 220kV û 110kV yên nûvekirin û rengkirin teknolojî, cihêna girîngkirina wêje nötr yan divê bexweste bibine:1. T
01/29/2026
Bisînhê Li Kîjan Diyan Bistîn û Dîwarên Berzok û Pirîvan Bistinandin?
چرا دەستگاھەکان دەستی کەمێک بە سەنجەر، شوێن، پیپڵ و چووندەکەن؟لە دەستگاھەکاندا، ئامێرەکەی جۆری ترانسفۆرمەری ناوڕاستی و ترانسفۆرمەری پاشتەر، خەوتە لێدەری، ترانسفۆرمەری هەژارە، ترانسفۆرمەری چاودێری، و چاودێرەکان هەمووی پێویستە بە گردن. لەوە ماوە، ئێستا دەبینین بەهۆی چی شوێن و چووندەکەرەکان زۆربەی کات پێشەوتن لە دەستگاھەکاندا بەکاردێت. گەرچە ئەوان پێشەوتن لە باشترین ڕوویان دەردەکەون، بەڵام ئەوان رولێکی گرنگی ئامانجی و کارکردنی دەبەستن.لە ڕێگەکەی گردنی دەستگاھ - بەخاصة کاتێک چەند ڕێگەی گردنیش هەبێت
01/29/2026
Pêşnîyar bişînin​
+86
کرتە بکە بۆ بارکردنی فایل
Daxistin
IEE-Business Zêdekirin Bîzînin Wekandin
Bi karanîna sepanê IEE-Business, li her der û her dem amûr bibînin, çareseriyan bistînin, bi pîsporan re têkiliyê ava bikin, û beşdarî hevkariya pîşesaziyê bibin — ev hemû ji pêşveçûna projeyên hêz û karsaziya we re piştgirîyeke tev e.​