What is a Transformer Connection?

Three-phase Transformer Connections Definition

A three-phase transformer connects its primary and secondary windings in star or delta configurations for various electrical applications.

Star Connection

In star connection, three windings connect at one end to form a neutral point, used for creating a neutral terminal.

3a452b29-f5d5-4ea7-b4c2-139efc1e1e46.jpg

In star connection, a line-to-line current is the same as a line-to-neutral current.

fce566079c07b183c51f8db966724d58.jpeg

we can find that the line-to-line voltage is √3 times line-to-neutral voltage.

ce6c20d0864ce0cefba59355dc4df02a.jpeg

Delta Connection

In delta connection, windings form a closed loop, creating a triangle-like shape, providing a path for the supply to the junction points.

6f4c813a-0bd7-4bbf-b701-5bea19ea85e1.jpg

we can find that the line-to-line current is √3 times line-to-neutral current.

line-to-line voltage is the same as line-to-neutral voltage.

895dfaf386c029b9b1d0a000102f9eed.jpeg

Types of Connections

Delta-Delta

58115b9d5580fb947cade69b50436bb7.jpeg

0d7f01a258ed209b9248d13a1e4ea965.jpeg

2a15d027f0f38cce84baa80ecc9a11ed.jpeg

The line current is √3 times phase current under balance condition. When magnetizing current is neglected, the current ratios is;

4cd2b953ac7d83d7c795107ff3447194.jpeg

Star-Star

1e8c75f8fae00af35a0285397d5c4392.jpeg 

9d4bce0556e97aef675a9301124b87a3.jpeg

 Delta-Star

5f3f87ff0a59d27095d2034b3a6e2c8b.jpeg

38fa37e596400b0f528870fd023eba46.jpeg

d74240aef2440d3478aa85de241ca18f.jpeg

Star-Delta

76a687fd-2558-4313-b061-dffc706aeff4.jpg


 

ddfe60e4228159af49d48ff1e8012529.jpeg

Open Delta Connection

This connection operates with two transformers, maintaining three-phase power with a lower load capacity when one transformer is out of service.

4c406983-4825-4898-ac30-c49a832e19bd.jpg




Give a tip and encourage the author!

Recommended

How to Test Insulation Resistance of Distribution Transformers
In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
12/25/2025
Design Principles for Pole-Mounted Distribution Transformers
Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
12/25/2025
Analysis of Common Faults and Causes in Routine Inspection of Distribution Transformers
Common Faults and Causes in Routine Inspection of Distribution TransformersAs the terminal component of power transmission and distribution systems, distribution transformers play a critical role in supplying reliable electricity to end users. However, many users have limited knowledge of power equipment, and routine maintenance is often carried out without professional support. If any of the following conditions are observed during transformer operation, immediate action should be taken: Excess
12/24/2025
Analysis of Lightning Protection Measures for Distribution Transformers
Analysis of Lightning Protection Measures for Distribution TransformersTo prevent lightning surge intrusion and ensure the safe operation of distribution transformers, this paper presents applicable lightning protection measures that can effectively enhance their lightning withstand capability.1. Lightning Protection Measures for Distribution Transformers1.1 Install surge arresters on the high-voltage (HV) side of the distribution transformer.According to SDJ7–79 Technical Code for Overvol
12/24/2025
Related Products
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.