Armature Winding

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Armature winding definition

The armature winding in an alternator is the arrangement of coils to generate electricity and is essential to its operation.

061f97b5bfa21348080ca26f2bf3bdca.jpeg

Type of armature winding

Single-phase armature winding

Single-phase armature windings can be centralized or distributed.

Centralized armature winding

When the number of slots on the armature equals the number of poles in the machine, the central winding is used. This winding type provides maximum output voltage, but is not always fully sinusoidal. The simplest single-phase winding is shown in Figure 1 below. Here, number of poles = number of slots = number of coil sides. Here, one coil side is located in a slot under one pole and the other coil side is located in the other slot under the next pole. The electromotive force induced on one coil side is added to the electromotive force on the adjacent coil side.

c7af039171783748adb550bb9b2f4fb7.jpeg

Distributed armature winding

To obtain a smooth sinusoidal electromotive force wave, the conductor is placed in several slots under the unipole. This kind of armature winding is called distributed winding. Although the distributed armature winding in an alternator reduces the electromotive force, it is still very usable for the following reasons.

  • It can also reduce the harmonic electromotive force, thus improving the waveform.

  • It also reduces armature reactions.

  • The evenly distributed conductors contribute to better cooling.

  • Because the conductors are distributed in slots on the periphery of the armature, the magnetic core is fully utilized.

Alternator lap winding

The 4-pole, 12-slot, 12-conductor (one conductor per slot) full-pitch lap winding of the alternator is shown below.

The back pitch of the winding is equal to the number of conductors per pole, that is, = 3, and the front pitch is equal to the back pitch minus 1.

fe6611627194cc64058146313a331bfc.jpeg

Wave winding of alternator

The waveform winding of the same machine, that is, four poles, 12 slots, 12 conductors, is shown in Figure e below. Here, both the back and front spacing are equal to a number of conductors per pole.

293bbf0da88f834b37853e616121e704.jpeg

Polyphase armature winding

Used in polyphase alternators to ensure balanced performance and efficient power generation between different phases.

Give a tip and encourage the author!
Recommended
In-Depth Analysis of Fault Protection Mechanisms for Generator Circuit Breakers
In-Depth Analysis of Fault Protection Mechanisms for Generator Circuit Breakers
1.Introduction1.1 Basic Function and Background of GCBThe Generator Circuit Breaker (GCB), as the critical node connecting the generator to the step-up transformer, is responsible for interrupting current under both normal and fault conditions. Unlike conventional substation circuit breakers, the GCB directly withstands the massive short-circuit current from the generator, with rated short-circuit breaking currents reaching hundreds of kiloamperes. In large generating units, the reliable operati
Felix Spark
11/27/2025
Research and Practice of Intelligent Monitoring System for Generator Circuit Breaker
Research and Practice of Intelligent Monitoring System for Generator Circuit Breaker
The generator circuit breaker is a critical component in power systems, and its reliability directly affects the stable operation of the entire power system. Through research and practical application of intelligent monitoring systems, the real-time operational status of circuit breakers can be monitored, enabling early detection of potential faults and risks, thereby enhancing the overall reliability of the power system.Traditional circuit breaker maintenance primarily relies on periodic inspec
Edwiin
11/27/2025
Why Install GCB at Generator Outlets? 6 Core Benefits for Power Plant Operations
Why Install GCB at Generator Outlets? 6 Core Benefits for Power Plant Operations
1.Protects the GeneratorWhen asymmetric short circuits occur at the generator outlet or the unit bears unbalanced loads, the GCB can quickly isolate the fault to prevent generator damage. During unbalanced load operation, or internal/external asymmetric short circuits, twice the power frequency eddy current is induced on the rotor surface, causing additional heating in the rotor. Meanwhile, the alternating electromagnetic torque at twice the power frequency induces double-frequency vibration in
Echo
11/27/2025
Silent Diesel Generator Installation Guide: Key Steps & Critical Details for Efficiency
Silent Diesel Generator Installation Guide: Key Steps & Critical Details for Efficiency
In industrial production, emergency rescue, commercial buildings, and other scenarios, silent-canopy diesel generator sets serve as the “core backup” for stable power supply. The quality of on-site installation directly determines the unit’s operational efficiency, noise control performance, and service life; even minor oversights may lead to potential faults. Today, based on practical experience, we outline the complete standardized procedures and critical details for on-site installation of si
James
11/27/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.