What is Line Regulation?

Edwiin
Edwiin
Field: Power switch
China

Definition: Voltage regulation (or line regulation) refers to the variation in voltage at the receiving end of a transmission line when the full load at a specified power factor is removed, with the sending-end voltage maintained constant. In simpler terms, it is the percentage change in the load-end voltage when transitioning from no-load to full-load conditions. This parameter is expressed as a fraction or percentage of the receiving-end voltage, serving as a critical metric for assessing the stability and performance of electrical power systems.

The line regulation is given by the equation shown below.

Here, Vrnl represents the magnitude of the receiving-end voltage at no load, and |Vrfl| represents the magnitude of the receiving-end voltage at full load.

Line voltage regulation is influenced by the load's power factor:

  • Lagging Power Factor: The sending-end voltage exceeds the receiving-end voltage at full load, resulting in positive regulation.

  • Leading Power Factor: The receiving-end voltage becomes higher than the sending-end voltage at full load, causing the line regulation to be negative (as the receiving-end voltage rises when the load is removed).

This phenomenon underscores how reactive power flow—dictated by power factor—alters voltage distribution along the transmission line.

Line Regulation for Short Lines:

For a short transmission line, the receiving-end voltage at no load Vrnl equals the sending-end voltage VS (assuming no significant reactive power effects). At full load,

The simplest method for measuring line regulation involves connecting three parallel resistors to the supply. Two resistors are linked to a switch, while the third is directly connected to the supply. The resistor values are selected such that the directly connected resistor has a high resistance, whereas the other two (connected in parallel via the switch) have nominal values. A voltmeter placed in parallel with each resistor measures the voltage across each line, providing data for calculating line voltage regulation.

Give a tip and encourage the author!
Recommended
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic Power Generation Systems
Composition and Working Principle of Photovoltaic (PV) Power Generation SystemsA photovoltaic (PV) power generation system is primarily composed of PV modules, a controller, an inverter, batteries, and other accessories (batteries are not required for grid-connected systems). Based on whether it relies on the public power grid, PV systems are divided into off-grid and grid-connected types. Off-grid systems operate independently without relying on the utility grid. They are equipped with energy-s
Encyclopedia
10/09/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(2)
1. On a scorching sunny day, do damaged vulnerable components need to be replaced immediately?Immediate replacement is not recommended. If replacement is necessary, it is advisable to do so in the early morning or late afternoon. You should contact the power station’s operation and maintenance (O&M) personnel promptly, and have professional staff go to the site for replacement.2. To prevent photovoltaic (PV) modules from being hit by heavy objects, can wire mesh protective screens be install
Encyclopedia
09/06/2025
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
How to Maintain a PV Plant? State Grid Answers 8 Common O&M Questions(1)
1. What are the common faults of distributed photovoltaic (PV) power generation systems? What typical problems may occur in various components of the system?Common faults include inverters failing to operate or start due to voltage not reaching the startup set value, and low power generation caused by issues with PV modules or inverters. Typical problems that may occur in system components are burnout of junction boxes and local burnout of PV modules.2. How to handle common faults of distributed
Leon
09/06/2025
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
Short Circuit vs. Overload: Understanding the Differences and How to Protect Your Power System
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit