Are there any magnets stronger than neodymium magnets? If yes, what are they called and how do they compare in strength to neodymium magnets?

10/05/2024

At present, Ndfeb magnets are considered to be one of the strongest magnets commercially available. They belong to the rare earth magnet category and are known for their high strength and high coercivity (i.e. the ability to resist demagnetization). However, there are some materials that can exhibit higher magnetic properties under certain conditions.


Samarium-cobalt magnet


Samarium cobalt magnets (SmCo) are also rare earth magnets, which are more stable than Ndfeb magnets at high temperatures. While their magnetic energy product (MGOe, a measure of a magnet's ability to store energy) may be slightly lower than Ndfeb magnets at room temperature, samarium-cobalt magnets exhibit better stability at high temperatures. The magnetic energy product of samarium cobalt magnets is about 24 to 32 MGOe, while the magnetic energy product of Ndfeb magnets can be as high as 52 MGOe or more.


Magnets in the lab


In addition to commercial magnets, a number of materials with higher magnetic properties have been synthesized in laboratory Settings, but they have not yet been widely used in commercial products.


Magnetic materials with perovskite structure


Scientists are working on a number of magnetic materials with perovskite structures that theoretically have the potential to provide higher magnetic energy products. However, the preparation and commercial application of these materials is still in the research stage.


Iron based superconductor


Iron-based superconductors can generate very strong magnetic fields at low temperatures, but this needs to be achieved at extremely low temperatures and is therefore not suitable for conventional permanent magnet applications.


Theoretical magnetic material


In theory, it is possible to develop magnetic materials that are stronger than Ndfeb magnets, but this requires the support of new alloy formulations and technological advances. For example, scientists have been exploring new combinations of rare earth elements in the hope of discovering stronger magnetic materials.


Sum up


Ndfeb magnets are currently one of the strongest magnets commercially available, with the highest magnetic energy product.Samarium cobalt magnets perform better in high temperature environments, but usually the magnetic energy product is slightly lower than Ndfeb magnets.


Magnets in the laboratory, such as perovskite-structured magnetic materials and iron-based superconductors, can exhibit higher magnetic properties under certain conditions, but these materials have not been widely used in commercial products.


When selecting magnets, in addition to magnetic properties, you need to consider the use environment, cost, temperature stability, and other application-specific requirements. Ndfeb magnets dominate the market due to their high performance and relatively low cost, but samarium-cobalt magnets are more suitable for certain high-temperature applications. Future magnetic material research may bring new breakthroughs, but there is no commercial magnet that is superior to Ndfeb magnets in all aspects.


Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.

Difference Between Short Circuit & Overload
Difference Between Short Circuit & Overload
One of the main differences between a short circuit and an overload is that a short circuit occurs due to a fault between conductors (line-to-line) or between a conductor and earth (line-to-ground), whereas an overload refers to a situation where equipment draws more current than its rated capacity from the power supply.Other key differences between the two are explained in the comparison chart below.The term "overload" typically refers to a condition in a circuit or connected device. A circuit
08/28/2025
Difference Between Leading and Lagging Power Factor
Difference Between Leading and Lagging Power Factor
Leading and lagging power factors are two key concepts related to the power factor in AC electrical systems. The main difference lies in the phase relationship between current and voltage: in a leading power factor, the current leads the voltage, whereas in a lagging power factor, the current lags behind the voltage. This behavior depends on the nature of the load in the circuit.What is Power Factor?Power factor is a crucial, dimensionless parameter in AC electrical systems, applicable to both s
08/26/2025
Difference Between Electromagnet and Permanent Magnet
Difference Between Electromagnet and Permanent Magnet
Electromagnets vs. Permanent Magnets: Understanding the Key DifferencesElectromagnets and permanent magnets are the two primary types of materials that exhibit magnetic properties. While both generate magnetic fields, they differ fundamentally in how these fields are produced.An electromagnet generates a magnetic field only when an electric current flows through it. In contrast, a permanent magnet inherently produces its own persistent magnetic field once it has been magnetized, without requirin
08/26/2025
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
Interpretation of the “Five Mandatory Surveys” for On - site Investigation in the Operation and Maintenance Specialty
The power outage and work scopes must be clearly inspectedCollaborate with the site survey leader to confirm the equipment to be maintained and the work area involved. Consider requirements such as the use of special vehicles and large machinery, and safe distances from adjacent energized equipment. Verify on-site whether the proposed power outage scope is sufficient to meet the operational needs.On-site safety measures must be clearly inspectedCollaborate with the site survey leader to verify s