• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Testing of Capacitor Bank
ANSI, IEEE, NEMA or IEC standard is used for testing a power capacitor bank.There are three types of test performed on capacitor banks. They are Design Tests or Type Tests. Production Test or Routine Tests. Field Tests or Pre commissioning Tests.Design Tests or Type Tests of Capacitor BankWhen a new design of power capacitor is launched by a manufacturer, it to be tested whether the new batch of capacitor comply the standard or not. Design tests or type tests are not performed on individual capa
03/23/2024
Consult
Tip
Consult
Tip
Location of Shunt Capacitors
The power factor improver capacitor can be installed at system bus, distribution point and at load itself. But decision should be taken in view of expenditure and utility.In certain loads mainly in industrial load, the entire load is switch ON or OFF based on need. In such cases it is recommended to install capacitor bank with the feeder which provides entire of this particular load. This scheme is known as branch capacitor bank scheme. As capacitor bank is directly connected to feeder or branch
03/23/2024
Consult
Tip
Consult
Tip
Types of Capacitor Bank
Unit of a capacitor bank is normally called capacitor unit. The capacitor units are manufactured as single phase unit. These single phase units are connected in star or delta to farm a complete 3 phase capacitor bank. Although some rare manufacturers 3 phase capacitor unit but normally available capacitor units are single phase type. The Externally fused capacitor bank. Internally fused capacitor bank. Fuse less capacitor bank.Let us discuss these types of capacitor bank one by one.Externally Fu
03/23/2024
Consult
Tip
Consult
Tip
Specifications or Rating of Power Capacitor Bank
A capacitor bank has to go through different abnormal system conditions, during its life span. To with stand these abnormalities at optimum manufacturing cost, the capacitor banks are rated with following allowable parameters. A capacitor bank should continue its service with in the following limits. 110 % of normal system peak voltage. 120 % of normal system rms voltage. 135 % of rated KVAR. 180 % of normal rated rms current.Voltage Rating of Capacitor BankA capacitor unit is normally designed
03/23/2024
Consult
Tip
Consult
Tip
Shunt Capacitor: What is it? (Compensation & Diagram)
What is a Shunt Capacitor?A capacitor bank is very essential equipment of an electrical power system. The power required to run all the electrical appliances is the load as useful power is active power. The active power is expressed in kW or MW. The maximum load connected to the electrical power system is mainly inductive in nature such as electrical transformer, induction motors, synchronous motor, electric furnaces, fluorescent lighting are all inductive in nature.In addition to these, inducta
03/23/2024
Consult
Tip
Consult
Tip
Synchronous Condenser
Like capacitor bank, we can use an overexcited synchronous motor to improve the poor power factor of a power system. The main advantage of using synchronous motor is that the improvement of power factor is smooth.When a synchronous motor runs with over-excitation, it draws leading current from the source. We use this property of a synchronous motor for the purpose.Here, in a three-phase system, we connect one three-phase synchronous motor and run it at no load.Suppose due to a reactive load of t
03/23/2024
Consult
Tip
Consult
Tip
Capacitor Bank: Definition, Uses and Benefits
A capacitor bank is a group of several capacitors of the same rating that are connected in series or parallel to store electrical energy in an electric power system. Capacitors are devices that can store electric charge by creating an electric field between two metal plates separated by an insulating material. Capacitor banks are used for various purposes, such as power factor correction, voltage regulation, harmonic filtering, and transient suppression.What is Power Factor?Power factor is a mea
03/23/2024
Consult
Tip
Consult
Tip
Measurement of Insulation Resistance
We defineinsulation resistanceas the ratio of applied direct voltage across an insulation to the corresponding current through it.Mesaurement of inslation resistance is quite important. We normally take the reading of the measurement at a certain time after application of test voltage. The standard duration of voltage application are 1 minute or 10 minutes. Because of that, insulation resistance can also be referred as 1 minute insulation resistance or 10 minute insulation resistance depending u
03/23/2024
Consult
Tip
Consult
Tip
Electrical Insulator Testing | Cause of Insulator failure
To ensure the desired performance of an electrical insulator, that is for avoiding unwanted insulator failure, each insulator has to undergo numbers of insulator test.Before going through testing of insulator we will try to understand different causes of insulator failure. Because insulator testing ensures the quality of electrical insulator and chances for failure of insulation depend upon the quality of insulator.Causes of Insulator FailureThere are different causes due to which failure of ins
03/23/2024
Consult
Tip
Consult
Tip
Insulation Coordination in Power System
Insulation Coordination in Power System was introduced to arrange the electrical insulation levels of different components in the electrical power system including transmission network, in such a manner, that the failure of insulator, if occurs, confindes to the place where it would result in the least danmage of the system, easy to repair and replace, and results least disturbance to the power supply.When any over voltage appears in the electrical power system, then there may be a chance of fai
03/23/2024
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.