Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Stator Earth Fault Protection of Alternator
This is to be noted that, the star point or neutral point of stator winding of an alternator is grounded through an impedance to limit the ground fault current. Reduced ground fault current causes less damage to the stator core and winding during ground or earth fault. If the ground impedance is made quite high, the ground fault current may become even less than normal rated current of the generator. If so, the sensitivity of phase relays becomes low, even they may fail to trip during fault. For
03/26/2024
Consult
Tip
Consult
Tip
Rotor Earth Fault Protection of Alternator or Generator
The rotor of an alternator is wound by field winding. Any single earth fault occurring on the field winding or in the exciter circuit is not a big problem for the machine. But if more than one earth fault occur, there may be a chance of short circuiting between the faulty points on the winding. This short circuited portion of the winding may cause unbalance magnetic field and subsequently mechanical damage may occur in the bearing of the machine due to unbalanced rotation.Hence it is always esse
03/26/2024
Consult
Tip
Consult
Tip
Inter Turn Fault Protection of Stator Winding of Generator
Inter turn stator winding fault can easily be detected by stator differential protection or stator earth fault protection. Hence, it is not very essential to provide special protection scheme for inter turn faults occurred in stator winding. This type of faults is generated if the insulation between conductors (with different potential) in the same slot is punctured. This type of fault rapidly changes to earth fault.The high voltage generator contains a large number of conductors per slot in the
03/26/2024
Consult
Tip
Consult
Tip
Generator Protection
A generator is subjected to electrical stresses imposed on the insulation of the machine, mechanical forces acting on the various parts of the machine, and temperature rise. These are the main factors which make protection necessary for the generator or alternator. Even when properly used, a machine in its perfect running condition does not only maintain its specified rated performance for many years, but it does also repeatedly withstand certain excess of overload.Preventive measures must be ta
03/26/2024
Consult
Tip
Consult
Tip
Differential Protection of Generator or Alternator
Any internal fault inside the stator winding is cleared by mainly differential protection scheme of the generator or alternator.The differential protection is provided in the generator by using longitudinal differential relay.Generally instantaneous attracted armature type relays are used for this purpose because all they have high speed operation and also they are free from being affected by any AC transient of the power circuit.There are two sets of current transformers, one CT is connected to
03/26/2024
Consult
Tip
Consult
Tip
Protection of Capacitor Bank
Like other electrical equipments, shunt capacitor may also be subjected to internal and external electrical faults. Hence this equipment is also to be protected from internal and external faults. There are numbers of schemes available for protection of capacitor bank, but during applying any of the schemes, we should remember the initial investment on that capacitor for economical point of view. We should compare the initial investment and the cost of the protection applying on it. There are mai
03/26/2024
Consult
Tip
Consult
Tip
Protection of Lines or Feeder
As the length of electrical power transmission line is generally long enough and it runs through open atmosphere, the probability of occurring fault in electrical power transmission line is much higher than that of electrical power transformers and alternators. That is why a transmission line requires much more protective schemes than a transformer and an alternator.Protection of line should have some special features, such as- During fault, the onlycircuit breakerclosest to the fault point shou
03/26/2024
Consult
Tip
Consult
Tip
Overvoltage Protection
There are always a chance of suffering an electrical power system from abnormal over voltages. These abnormal over voltages may be caused due to various reason such as, sudden interruption of heavy load, lightening impulses, switching impulses etc. These over voltage stresses may damage insulation of various equipments and insulators of the power system. Although, all the over voltage stresses are not strong enough to damage insulation of system, but still these over voltages also to be avoided
03/26/2024
Consult
Tip
Consult
Tip
Busbar Protection | Busbar Differential Protection Scheme
In early days only conventional over current relays were used for busbar protection. But it is desired that fault in any feeder or transformer connected to the busbar should not disturb busbar system. In viewing of this time setting of busbar protection relays are made lengthy. So when faults occurs on busbar itself, it takes much time to isolate the bus from source which may came much damage in the bus system.In recent days, the second zone distance protection relays on incoming feeder, with op
03/26/2024
Consult
Tip
Consult
Tip
Motor Protection Circuit Breaker or MPCB
Motor protection circuit breakers are a specialized type of electrical protection device that is designed specifically for electric motors, like their name implies. Electric motors have plenty of applications and are used to drive mechanical devices of all types, so it is very important to protect them adequately with MPCBs. The following are just a few examples of devices driven by electric motors in commercial and industrial buildings: Rooftop air conditioners, chillers, compressors, heat pump