Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Operational Analysis and Maintenance Strategies for High-Voltage Disconnect Switches in Power Systems
I. Operational Analysis1.1 Operating ScopeHigh-voltage disconnect switches are classified into outdoor and indoor types based on installation location, and into three-pole or single-pole configurations according to the number of poles. During operation, attention must be closely paid to the switch’s operating current and voltage.If the operating voltage exceeds the rated value, discharge may occur within the porcelain insulator. The degree of heating is closely related to the operating current a
09/26/2025
Consult
Tip
Consult
Tip
Analysis of Arcing Hazards in High-Voltage Disconnect Switches and Preventive Measures
During the operation of high-voltage disconnect switches, arcs may form between the contacts when they separate while current is still flowing. The high temperature of the arc not only damages the switch contacts but can also ignite surrounding flammable materials, leading to safety accidents.Arc formation is influenced by various factors, including the type of current (DC or AC), the inductive and capacitive characteristics of the circuit, and the properties of the contact materials. In DC syst
09/26/2025
Consult
Tip
Consult
Tip
Research on Mechanical Fault Analysis and Improvement Techniques of High-Voltage Disconnector Switches
With the continuous advancement of mechanization in modern society, the demand for electrical energy in daily life has significantly increased. To ensure that power supply meets this growing demand, the power system must operate with greater stability, safety, and real-time responsiveness. This highlights the critical importance of high-voltage disconnector switch quality during manufacturing.Manufacturers must strengthen their awareness of this responsibility to ensure reliable operation of hig
09/25/2025
Consult
Tip
Consult
Tip
 RCD Keeps Tripping? Find the Real Cause Fast
How Residual Current Devices (RCDs) Work and Why They TripA residual current device (RCD), also known as a leakage circuit breaker, trips when it detects a current imbalance of 30mA or more between the live and neutral conductors. In older electrical circuits, or in installations where cables were not run through conduits, it can be extremely difficult to use RCDs effectively. Even if the system works initially, during damp or humid weather, the RCD may trip repeatedly. Identifying the exact cau
09/25/2025
Consult
Tip
Consult
Tip
Air Circuit Breaker Tripping? 90% Overlook This Critical Cause!
In daily life and industrial operations, we often encounter circuit breakers tripping. Common causes include faulty breakers themselves or leakage/short circuits in the load. However, some tripping incidents have unexpected origins.At a mine, an emergency backup power system consisted of a diesel generator (400V), which fed a mining transformer (10,000V–400V) to step up voltage and supply power to the underground shaft. One rainy day, the main grid power failed. To ensure safety underground, the
09/25/2025
Consult
Tip
Consult
Tip
Circuit Breaker Selection and Setting: A Complete Guide from Basic Parameters to Selective Protection
Classification of Circuit Breakers(1) Air Circuit Breaker (ACB)An air circuit breaker, also known as a molded frame or universal circuit breaker, houses all components within an insulated metal frame. It is typically open-type, allowing installation of various accessories, and facilitates easy replacement of contacts and parts. It is commonly used as the main power supply switch. Overcurrent trip units include electromagnetic, electronic, and intelligent types. The breaker provides four-stage pr
09/25/2025
Consult
Tip
Consult
Tip
 Is Your High-Pressure Heat Exchanger Always Failing? These 4 Common Faults You Must Know
The magnitude of pressure drop directly affects the energy consumption of the unitIn hydrocracking units, most high-pressure heat exchangers are used in the recycle hydrogen circuit, where the pressure drop directly impacts the energy consumption of the recycle hydrogen compressor. For once-through hydrocracking units, the energy consumption of the recycle hydrogen compressor accounts for approximately 15%–30% of the total unit energy consumption. Therefore, the pressure drop across the high-pre
09/25/2025
Consult
Tip
Consult
Tip
 Working Principle and Maintenance Key Points of 10kV High-Voltage Reactive Power Compensation Device
The 10kV high-voltage reactive power compensation device is an essential and indispensable component in modern power systems. By providing or absorbing reactive power, it effectively addresses issues such as low power factor, high line losses, and voltage fluctuations caused by reactive power demand, playing a key role in improving the economy, safety, and power quality of grid operation. High-voltage 10kV reactive power compensation is a critical device for ensuring safe and economical grid ope
09/25/2025
Consult
Tip
Consult
Tip
Layout Requirements for High-Voltage and Low-Voltage Switchgear Rooms: Optimizing Space Arrangement and Safety Clearances
High-Voltage Switchgear Room When the length of a high-voltage switchgear room exceeds 7m, two doors should be provided, preferably located at opposite ends. The access door for handling GG-1A type switchgear should be 1.5m wide and 2.5–2.8m high. Recommended dimensions for operating aisles in front of fixed switchgear: 2m for single-row layout and 2.5m for double-row layout, measured from the front of the panels. When a large number of switchgear units are installed, the aisle width may be appr
09/18/2025
Consult
Tip
Consult
Tip
What is the function of a low-voltage electrical room, and what equipment does it consist of?
What is a Switchgear Room?A switchgear room is an indoor electrical distribution facility that supplies power to low-voltage consumers. It typically includes medium-voltage incoming lines (with limited outgoing lines), distribution transformers, and low-voltage switchgear. Facilities operating at 10kV or below are categorized as either high-voltage or low-voltage switchgear rooms. A high-voltage switchgear room generally refers to a 6kV–10kV high-voltage switch compartment, while a low-voltage s