Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Enhancing Power Transformer Resilience in the Face of Climate Change
Enhancing Power Transformer Resilience in the Face of Climate ChangeClimate change poses significant challenges to power infrastructure, with power transformers—critical components of the electrical grid—particularly vulnerable. As extreme weather events grow more frequent and severe, ensuring the resilience of transformers has become a top priority for utilities and power companies worldwide.Understanding the VulnerabilitiesModern transformers face a growing array of clim at
08/05/2025
Consult
Tip
Consult
Tip
Technical Specifications for Climate-Adaptive Transformer Designs
As the frequency and severity of climate-related events such as storms, floods, and wildfires continue to rise, the development of climate-adaptive transformer designs has become an urgent need. Transformers, as a core component of power infrastructure, their ability to withstand extreme weather conditions is directly related to the stability of power supply. This article explores the technical specifications defining climate-adaptive transformer designs, focusing on four key dimensions: materia
08/04/2025
Consult
Tip
Consult
Tip
Derivation & Analysis of Peak/RMS Characteristics of 1.75T Magnetic Flux Density in Oil-Immersed Transformer Core
Generally speaking, the designed working magnetic flux density of the iron core in an oil-immersed power transformer can be around 1.75T (the specific value depends on factors such as no-load loss and noise requirements). However, there is a seemingly basic yet easily confusing question: is this 1.75T magnetic flux density value a peak value or an effective value?Even when asking an engineer with many years of experience in transformer design, they may not be able to give an accurate answer imme
08/04/2025
Consult
Tip
Consult
Tip
Hazards Causes and Types of Transformer Core Multi point Ground Faults
Hazards of Multi-point Core Ground FaultsA transformer core must not have multi-point grounding during normal operation. An alternating magnetic field around the winding induces parasitic capacitances between windings, core, and shell. Live windings couple through these capacitances, creating a core floating potential relative to ground. Uneven distances between components cause potential differences; when high enough, they spark. This intermittent discharge degrades transformer oil and solid in
08/02/2025
Consult
Tip
Consult
Tip
Photovoltaic Power Generation Process Common Faults Causes and Solutions
1. Brief Introduction to the Photovoltaic Power Generation ProcessThe operation process of photovoltaic power generation is as follows: First, individual solar panels are connected in series to form photovoltaic modules, and the modules are arranged in parallel through combiner boxes to form a photovoltaic array. Solar energy is converted into direct current (DC) by the photovoltaic array, and then converted into three-phase alternating current (AC) through a three-phase inverter (DC - AC). Subs
08/02/2025
Consult
Tip
Consult
Tip
Common Electrical Equipment Questions and Answers
Why is a ZnO surge arrester installed between the power capacitor and its breaker?A ZnO surge arrester is installed to prevent overvoltage caused by switching operations, thereby ensuring the safe operation of electrical equipment. What is the difference between an energy meter and a power meter?A power meter indicates the instantaneous power output or consumption, while an energy meter records the total energy produced, transmitted, or consumed over a specific period. What are the requirements
08/02/2025
Consult
Tip
Consult
Tip
Shunt and Series Linear Voltage Regulators Definition and Comparison
Linear voltage regulators are mainly classified into shunt voltage regulators and series voltage regulators. The key difference between the two lies in their control element configurations: in a shunt voltage regulator, the control element is connected in parallel with the load, whereas in a series voltage regulator, the control element is connected in series with the load. These two regulator circuits operate on distinct principles, thus each having its own advantages and disadvantages, which w
08/02/2025
Consult
Tip
Consult
Tip
Aluminum vs Copper Windings in Power Transformers: Cost & Performance Comparison
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
08/01/2025
Consult
Tip
Consult
Tip
Inverter-Integrated Transformers: Functions, Applications, and Benefits in Renewable Energy
An inverter-integrated transformer is a power conversion device that combines the functions of an inverter and a transformer into a single unit. Widely utilized in renewable energy systems such as solar photovoltaic (PV) and wind power generation, its primary role is to convert direct current (DC) to alternating current (AC) while adjusting voltage levels (stepping up or down) via the transformer, ensuring compatibility with grid requirements or specific load demands.1. Basic Functions and Opera
07/31/2025
Consult
Tip
Consult
Tip
Process Improvement for Consistent Transformer Manufacturing: Inductance Control & Performance Optimization
Given the lack of manufacturers for such transformers on the market, we design them in - house. We provide technical specs to partners, specifying materials like high - temp enameled wires.Electrical signals from downhole logging tools, transmitted via these transformers, impact formation - to - surface signal reliability. Thus, improving transformer consistency boosts signal uniformity, enhancing logging tool accuracy and our market competitiveness.Our common signal transformers are EI - type,
07/28/2025
Consult
Tip
Consult
Tip
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.