Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
How Do Intelligent Monitoring and Innovations Advance Low-Voltage Voltage Transformer Development?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and p
07/16/2025
Consult
Tip
Consult
Tip
What Are Key Points for Configuration Selection and Installation of Low-Voltage Current Transformers?
1. Selection of Low - Voltage Current Transformer ConfigurationThere are many factors leading to wrong selection of low - voltage current transformers in civil construction projects. For example, common factors include design problems: the calculated coefficient designed for the load of electrical equipment is relatively large, or the transformation ratio of the current transformer is selected incorrectly. Such a series of reasons will affect the use of electrical equipment. Therefore, in the co
07/16/2025
Consult
Tip
Consult
Tip
What Is the Fast Verification Wiring Method for Low-Voltage Current Transformers?
To ensure safe operation of the power system, power equipment operation must be monitored/measured. General devices can’t connect to primary high - voltage equipment directly; instead, large primary currents are scaled down for current transformation, electrical isolation, and use by measurement/protection devices. For AC large - current measurement, conversion to a unified current eases secondary instrument use.Current transformers split into measurement - and protection - type, with
07/16/2025
Consult
Tip
Consult
Tip
Research on Low-Voltage Anti-DC Current Transformers and Their Detection Methods
1. Overview of Components and IssuesTA (low-voltage current transformer) and electric energy meters are key components of low-voltage electric energy metering. The load current of such meters is no less than 60A. Electric energy meters vary in type, model, and anti-DC performance, and are connected in series in the metering device. Due to the lack of anti-DC capability, they suffer from metering errors under DC component loads, usually caused by non-linear loads. With the increasing use of DC or
07/16/2025
Consult
Tip
Consult
Tip
Development and Application of Anti-Theft Device for Low-Voltage Current Transformers
1. Innovation BackgroundWith the progress of society and economic development, the electricity demand of power users is expanding increasingly. Lawbreakers, aiming to save electricity costs and pursue high profits, gradually use high - tech methods to steal electricity, causing huge economic losses to power supply enterprises. Currently, popular electricity theft methods in the market include illegally opening the wiring cover of low - voltage transformers in electric energy metering boxes, alte
07/16/2025
Consult
Tip
Consult
Tip
How Does Temperature Change Affect AIS Voltage Transformers?
Impact on Insulation Performance Changes in Insulating Material Properties: AIS voltage transformers rely on air as the insulating medium, and they also contain some solid insulating materials, such as insulating paper and insulating bushings. When the temperature rises, the migration and evaporation of moisture in solid insulating materials like insulating paper will accelerate, resulting in a decrease in the electrical strength of the insulating materials and an increased risk of insulation br
07/15/2025
Consult
Tip
Consult
Tip
How to Solve Single-Phase Grounding Fault Judgment for 3-Phase 4PT in Ungrounded Systems?
In 10 kV and 35 kV ungrounded systems, single - phase grounding faults cause minimal current, so protection rarely trips. Per regulations, operation is limited to 2 hours; prolonged undetected faults may worsen, even damaging switches. While the State Grid promotes small - current grounding line selection devices in 110 kV and 220 kV substations, their accuracy remains low, requiring monitoring/operation staff to analyze remote measurements. For ungrounded systems with three - phase 4PT voltage
07/15/2025
Consult
Tip
Consult
Tip
What Are the Essentials for Selecting and Installing 66kV Outdoor AIS Voltage Transformers?
Hey everyone! I'm James, a professional with over 10 years of experience installing voltage transformers. Today, I want to talk about the selection and installation of Air Insulated Switchgear (AIS) voltage transformers in 66kV outdoor substations.These devices are critical for measurement and protection in power systems. Their proper selection and installation directly affect the safety and stability of the entire electrical grid. With the advancement of smart grid technology, electronic AIS vo
07/15/2025
Consult
Tip
Consult
Tip
How is the application and development of AIS voltage transformers in 66kV outdoor substations?
Hey everyone! I’m Echo, and today we’re diving into the application and development of Air Insulated Switchgear (AIS) voltage transformers in 66kV outdoor substations. These devices play a crucial role in power systems, not just for measurement but also for protection and control. As technology advances, they continue to evolve to meet higher performance demands and stricter environmental standards. Let’s take a closer look!Applications Voltage Measurement One of
07/15/2025
Consult
Tip
Consult
Tip
What Tests Are Required for a Qualified AIS Voltage Transformer?
Hey everyone! I’m Oliver, an experienced electrician with over a decade in the power system industry. Today, we’re diving into a practical topic — what tests are required to ensure an Air Insulated Switchgear (AIS) voltage transformer is qualified? These tests are crucial not only for ensuring the device operates correctly but also for maintaining the safety and stability of the power grid. Let’s get started!1. Visual InspectionFirst Look MattersThe very f