How is the application and development of AIS voltage transformers in 66kV outdoor substations?

Echo
07/15/2025

Hey everyone! I’m Echo, and today we’re diving into the application and development of Air Insulated Switchgear (AIS) voltage transformers in 66kV outdoor substations. These devices play a crucial role in power systems, not just for measurement but also for protection and control. As technology advances, they continue to evolve to meet higher performance demands and stricter environmental standards. Let’s take a closer look!

Applications

  • Voltage Measurement

    • One of the primary tasks of AIS voltage transformers is converting high voltages into low-voltage signals that meters can easily read and monitor.
  • Power System Protection

    • They work alongside relay protection devices to detect and respond to anomalies like overvoltage and undervoltage, ensuring the safe operation of the grid.
  • Synchronization Detection

    • During grid synchronization operations, they provide necessary voltage signals to ensure synchronization between generators and the grid—a critical step.
  • Energy Metering

    • Paired with current transformers, they enable precise energy metering, which is essential for billing by power companies and managing user consumption.
  • Control and Signal Transmission

    • In automation and remote control systems, voltage transformers convert voltage signals into suitable low-voltage signals for easier monitoring and control.

Development Trends

  • Intelligent and Digital Features

    • Modern voltage transformers are getting smarter, integrating real-time data acquisition, fault prediction, and self-diagnosis functions. This significantly enhances grid reliability and efficiency.
  • Precision and Compact Design

    • Improving measurement accuracy while reducing size makes these devices more suitable for limited space installations and easier to transport and maintain.
  • Eco-friendly Materials and Technologies

    • Using more environmentally friendly materials reduces environmental impact and enhances the sustainability of the equipment.
  • Standardization and Globalization

    • Equipment design and production are increasingly aligned with international standards, promoting global trade and improving product compatibility and quality.
  • Enhanced Reliability

    • To handle harsh working environments (like high temperatures, humidity, and salt fog corrosion), more durable materials and protective measures are used to ensure long-term stability.
  • Increased Security

    • With the rise of cybersecurity threats, especially in smart grids, the security of voltage transformers has become even more important. This includes both physical protection and encrypted communication methods.
  • Customized Services

    • Offering customized solutions based on user needs better adapts to different application scenarios and specific requirements.

Conclusion

In summary, 66kV outdoor substation AIS voltage transformers aren’t just about measuring voltage; they play significant roles across various aspects of power systems. Future developments focus on enhancing device intelligence, optimizing designs, and improving stability and security under various conditions. As technology progresses, these devices will continue to evolve to support increasingly complex power network demands.

I hope this article helps you gain a clearer understanding of 66kV outdoor substation AIS voltage transformers. If you have any questions or want to share your experiences, feel free to leave a comment or send me a message. Let’s learn together and improve collectively!

— Echo

Echo

As an expert in the application and trends of electrical equipment, I have a profound mastery of knowledge in circuits, power electronics, etc. I possess a comprehensive set of abilities including equipment design, fault diagnosis, and project management. I can precisely grasp the industry's pulse and lead the development of the electrical field.

What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
What aspects should be taken into consideration during the design of AIS voltage transformers?
What aspects should be taken into consideration during the design of AIS voltage transformers?
I. Key Elements of Mechanical Structure DesignThe mechanical structure design of AIS voltage transformers ensures long - term stable operation. For 66 kV outdoor AIS voltage transformers (pillar - type structure):Pillar Material: Use epoxy resin casting + metal frame for mechanical strength, pollution/weather resistance. Special design needed for 66 kV (vs 35 kV & below). Dry - type insulation (porcelain/epoxy shell) requires sufficient bending/impact resistance for harsh outdoors.Heat Dissi
Dyson
07/15/2025
What are the impacts of temperature on AIS voltage transformers?
What are the impacts of temperature on AIS voltage transformers?
Impact on Insulation PerformanceChanges in Insulating Material Properties: AIS voltage transformers rely on air as the insulating medium, and they also contain some solid insulating materials, such as insulating paper and insulating bushings. When the temperature rises, the migration and evaporation of moisture in solid insulating materials like insulating paper will accelerate, resulting in a decrease in the electrical strength of the insulating materials and an increased risk of insulation bre
Echo
07/15/2025
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
Fault Analysis of Single - Phase Grounding of Three - Phase 4PT Voltage Transformer
In 10 kV and 35 kV ungrounded systems, single - phase grounding faults cause minimal current, so protection rarely trips. Per regulations, operation is limited to 2 hours; prolonged undetected faults may worsen, even damaging switches. While the State Grid promotes small - current grounding line selection devices in 110 kV and 220 kV substations, their accuracy remains low, requiring monitoring/operation staff to analyze remote measurements. For ungrounded systems with three - phase 4PT voltage
Felix Spark
07/15/2025
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!