Free Expert Guides on Power Systems, Circuit Design & Electrical Troubleshooting

Access free engineering resources from IEE Business—covering power design, circuit layout, equipment selection, and troubleshooting. Expert-developed guides help engineers, procurement, and project teams make better decisions. Stay ahead on smart grids, renewables, efficiency, and AI tools. Improve reliability, reduce downtime, and enhance outcomes with real-world solutions. Explore our knowledge hub today.
Factors of Contactor’s Contact Design
Factors in Contactor Contact DesignThe following factors are considered when designing contactor contacts:Current-Carrying CapacityThe current-carrying capacity of contacts is a primary consideration in design, directly influencing material selection. Hard-drawn copper or forged copper are preferred choices to ensure optimal performance.Contact PressureContact pressure is directly proportional to current-carrying capacity—an increase in pressure enhances the contact's ability to carry
05/19/2025
Consult
Tip
Consult
Tip
HRC Fuse (High Rupturing Capacity Fuse) and its Types
What is a High Rupturing Capacity (HRC) Fuse?A High Rupturing Capacity (HRC) fuse is a type of protective device used in electrical systems to safeguard against overcurrent and short-circuit faults. It is engineered to safely interrupt high-magnitude fault currents without causing damage to surrounding equipment or itself. HRC fuses can reliably handle and clear large fault currents, typically up to 80 kA or higher, while eliminating risks of explosion or fire.An HRC fuse contains a fuse element
05/19/2025
Consult
Tip
Consult
Tip
What are the differences between neutral line, grounding and ground contact?
What are the differences between neutral line, grounding and ground contact?To grasp the distinctions among Neutral, Ground, and Earth, we must first understand the purposes of these elements.NeutralThe neutral wire serves as the return path for electric current in an electrical circuit, designed to carry current under normal operating conditions. This current primarily arises from phase current imbalances and occasionally from the presence of 3rd and 5th harmonics.The neutral wire provides a pa
05/19/2025
Consult
Tip
Consult
Tip
What is Peak Inverse Voltage (PIV)?
DefinitionThe maximum value of the reverse voltage that a PN junction or diode can withstand without damage is termed thePeak Inverse Voltage (PIV). This PIV rating is specified and explained in the datasheet provided by the manufacturer.However, if the voltage across the junction under reverse bias exceeds this specified value, the junction will be damaged.As shown in the figure above, a PN junction or diode is commonly used as a rectifier, i.e., to convert alternating current (AC) to direct cu
05/19/2025
Consult
Tip
Consult
Tip
What is a Form Factor?
DefinitionTheForm Factoris defined as the ratio of the root mean square (R.M.S) value to the average value of an alternating quantity (either current or voltage). The average value of an alternating quantity is the arithmetic mean of all instantaneous values of current or voltage over one complete cycle.Mathematically, it is expressed as:Ir.m.s and Er.m.s are the root-mean-square values of current and voltage respectively, while Iav and Eavare the average values of alternating current and voltag
05/19/2025
Consult
Tip
Consult
Tip
What is a Peak Factor?
DefinitionThe Peak Factor is defined as the ratio of the maximum value to the root - mean - square (R.M.S) value of an alternating quantity. The alternating quantity can be either voltage or current. The maximum value refers to the peak value, crest value, or amplitude of the voltage or current. The root - mean - square value is the value of direct current that, when passed through the same resistance for the same given time, produces the same amount of heat as the alternating current.Mathematic
05/19/2025
Consult
Tip
Consult
Tip
A Brief Discussion on the Design of a New American-Style Box-type Substation for Wind Power Generation
IntroductionAs a clean and renewable energy source, wind energy has increasingly attracted the attention of countries around the world. Its reserves are enormous. The total global wind energy resources amount to approximately 2.74×10⁹ MW, of which the exploitable wind energy is 2.0×10⁷ MW. In China, wind energy reserves are large, widely distributed, and the potential for development and utilization is huge. Wind power generation has developed rapidly in recent years, and the
05/17/2025
Consult
Tip
Consult
Tip
Analysis of Standards and Structural Performance of combined distribution equipment
Standards and Classification of Combined Power Distribution DevicesThere is a relatively large variety of combined power distribution devices. Commonly used ones include packaged substations, box - type transformers, pre - assembled substations, combined transformers, European - style box substations, and American - style box substations.Relevant Standards for Combined Power Distribution DevicesThe currently effective relevant standards for combined power distribution devices in China mainly inc
05/17/2025
Consult
Tip
Consult
Tip
Transformers Fire Protection System – Causes, Types & Requirements
Causes of Transformer FiresTransformers can catch fire due to several critical issues, includingexcessive overheating,severe short circuits,faults in the insulating oil, andlightning strikes. While transformer fires are relatively uncommon, their consequences can be devastating. As depicted in the figure below, a transformer engulfed in fire is often irreparably damaged within minutes. However, it is crucial to address the potential impact of such fires on adjacent equipment and structures, as p
05/17/2025
Consult
Tip
Consult
Tip
Types & Characteristics of Surge Arresters
IntroductionAtmospheric lightning strikes on overhead lines, bare conductors, or metallic structures in outdoor substations, as well as overvoltages caused by switching operations of equipment and networks (switching overvoltages), pose significant hazards to electrical equipment. To protect equipment and facilitate insulation coordination,surge arresters(also known as "lightning arresters") must be installed at the incoming/outgoing points of overhead lines and in close proximity to transformer
05/17/2025
Consult
Tip
Consult
Tip