Minera MP Oil Immersed Medium Power Transformers

  • Minera MP Oil Immersed Medium Power Transformers

Key attributes

Brand Schneider
Model NO. Minera MP Oil Immersed Medium Power Transformers
Rated frequency 50/60Hz
Series Minera MP

Product descriptions from the supplier

Description

General

Our broad range for Minera MP transformers includes:

  • Three phase units (single phase available on request)

  • Ratings up to 80 MVA, 50 or 60 Hz

  • Voltage insulation level up to 170 kV

  • Breathing or sealed type

  • A wide range of accessories

  • High capacity cooling options such as ONAN, ONAF, OFAF, OFWF or others upon request

  • Standard or low noise levels

  • Off-circuit tap changer (OCTC) or on load tap changer (OLTC)

Minera MP oil-immersed transformers are also available upon request for special applications including rectifier, hazardous area transformers, reactors (shunt and series), auto-transformers, step-up transformers, Solar power plant , Wind Mill Application etc.
Minera MP oil-immersed transformers meet the requirements of international standards such as ANSI, IEEE, IEC as well as other international/national standards.

 

Technical caracteristics 

 

The right tune for your network

Depending on your application and the different environmental influences you meet, we are able to deliver you a large variety of Minera MP transformers. Schneider Electric’s R&D team has created special designs for all your particular needs:

  • Breathing type and sealed type

  • For indoor application in buildings or industrial plants and in compact distribution substations

  • For outdoor applications

  • Normal noise level for urban or residential areas

  • Normal, low or very low level of losses

As customer satisfaction is our main concern, we constantly improve our manufacturing process, thus we are able to speed up delivery time while ensuring that all ISO 9001, ISO 14001 and/or ISO 18001 requirements are met at each production step. To ensure this high level of quality, our Minera MP transformers undergo routine tests in accordance with international standards such as IEC, ANSI standards. We can also provide type tests or special tests on request.

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 400000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 400000000
Services
Business Type: Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How Often Should Transformers Be Overhauled?
    1. Transformer Major Overhaul Cycle The main transformer shall undergo a core-lifting inspection before being put into service, and thereafter a core-lifting overhaul shall be performed every 5 to 10 years. Core-lifting overhaul shall also be carried out if a fault occurs during operation or if issues are identified during preventive tests. Distribution transformers operating continuously under normal load conditions may be overhauled once every 10 years. For on-load tap-changing transformers, t
    12/09/2025
  • Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
    Preparatory Work Before Adjusting the Tap Changer of H61 Oil Power 26kV Electric Transformer Apply for and issue a work permit; carefully fill out the operation ticket; conduct a simulation board operation test to ensure the operation is error-free; confirm the personnel who will carry out and supervise the operation; if load reduction is required, notify affected users in advance. Before construction, power must be disconnected to take the transformer out of service, and voltage testing must be
    12/08/2025
  • H59/H61 Transformer Failure Analysis and Protection Measures
    1.Causes of Damage to Agricultural H59/H61 Oil-Immersed Distribution Transformers1.1 Insulation DamageRural power supply commonly uses a 380/220V mixed system. Due to the high proportion of single-phase loads, H59/H61 oil-immersed distribution transformers often operate under significant three-phase load imbalance. In many cases, the degree of three-phase load imbalance far exceeds the limits permitted by operational regulations, causing premature aging, deterioration, and eventual failure of th
    12/08/2025
  • What Is an H61 Distribution Transformer? Uses & Setup
    H61 distribution transformers refer to transformers used in power distribution systems. In a distribution system, high-voltage electricity must be converted into low-voltage electricity via transformers to supply electrical equipment in residential, commercial, and industrial facilities. The H61 distribution transformer is a type of infrastructure equipment primarily used in the following scenarios: Supplying power from high-voltage grids to low-voltage grids: During power delivery, high-voltage
    12/08/2025
  • How to Diagnose Faults in H59 Distribution Transformers by Listening to Their Sounds
    In recent years, the accident rate of H59 distribution transformers has shown an upward trend. This article analyzes the causes of failures in H59 distribution transformers and proposes a series of preventive measures to ensure their normal operation and provide effective assurance for power supply.H59 distribution transformers play a vital role in power systems. With the continuous expansion of power system scale and the increasing single-unit capacity of transformers, any transformer failure n
    12/08/2025
  • What lightning protection measures are used for H61 distribution transformers?
    What lightning protection measures are used for H61 distribution transformers?A surge arrester should be installed on the high-voltage side of the H61 distribution transformer. According to SDJ7–79 "Technical Code for Design of Overvoltage Protection of Electric Power Equipment," the high-voltage side of an H61 distribution transformer should generally be protected by a surge arrester. The grounding conductor of the arrester, the neutral point on the low-voltage side of the transformer, and the
    12/08/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.