Surge Arresters for Transformer Neutral Points

  • Surge Arresters for Transformer Neutral Points

Key attributes

Brand ROCKWILL
Model NO. Surge Arresters for Transformer Neutral Points
Rated voltage 60kV
Rated frequency 50/60Hz
Series Y1.5W

Product descriptions from the supplier

Description

Description

Surge Arresters for Transformer Neutral Points are specialized protective devices designed to safeguard the neutral points of transformers in power systems. Installed at the neutral connection of transformers, they mitigate transient overvoltages that may occur at the neutral point due to lightning strikes, system faults (such as single-phase grounding faults), or switching operations. By rapidly conducting surge currents to the ground and clamping the voltage to a safe level, these arresters prevent damage to the transformer's insulation, core, and windings, ensuring the transformer's stable operation and extending its service life.

Features

  • Neutral Point-Specific Design: Tailored to the electrical characteristics of transformer neutral points, with voltage and current ratings matching the neutral point's operating conditions, ensuring precise protection without affecting the transformer's normal operation.

  • Effective Overvoltage Suppression: Equipped with high-performance metal oxide varistors (MOVs) that respond quickly to transient overvoltages at the neutral point, limiting voltage spikes to levels within the transformer's insulation tolerance.

  • Resistance to DC Bias Impact: Capable of withstanding DC bias currents that may occur in the neutral point due to system imbalances, avoiding performance degradation or damage caused by long-term DC stress.

  • Compact and Easy Installation: Adopt a compact structure suitable for installation in transformer substations with limited space, featuring flexible mounting options to adapt to different transformer neutral connection layouts.

  • Durable and Reliable: Housed in materials like composite silicone rubber or porcelain, with strong resistance to moisture, pollution, and temperature variations, ensuring stable operation in harsh outdoor or indoor environments.

  • Low Leakage Current: Maintain minimal leakage current during normal operation, reducing energy loss and avoiding unnecessary heating, which helps maintain the transformer's operational efficiency.

  • Compliance with Standards: Meet international standards such as IEC and IEEE, undergoing rigorous testing to ensure compatibility with various transformer types and reliable performance in different power system configurations.

  • Coordination with System Protection: Designed to coordinate with other protection devices in the power system, such as circuit breakers and fuses, forming a comprehensive protection network to enhance the overall safety of the transformer and the system.

Model

Arrester

System

Arrester Continuous Operation

DC 1mA

Switching Impulse

Nominal Impulse

Steep - Front Impulse

2ms Square Wave

Nominal

Rated Voltage

Nominal Voltage

Operating Voltage

Reference Voltage

Voltage Residual (Switching Impulse)

Voltage Residual (Nominal Impulse)

Current Residual Voltage

Current - Withstand Capacity

Creepage Distance

kV

kV

kV

kV

kV

kV

kV

A

mm

(RMS Value)

(RMS Value)

(RMS Value)

Not Less Than

Not Greater Than

Not Greater Than

Not Greater Than

20 Times






(Peak Value

(Peak Value

(Peak Value

(Peak Value


Y1.5W1-60/144W

60

48

110

85

135

144


100

2370

1.5W1-72/186W

72

58

110

103

174

186


400

2370

Y1.5W1-96/260W

96

77

500

137

243

260


400

3150

Y1.5W1-144/320W

144

116

220

205

299

320


400

4740

Y1.5W1-144/320W

144

116

220

205

299

320


400

3906

Y1.5W1-207/440W

207

166

330

292

410

440


400

6300

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
    1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
    07/31/2025
  • Surge Arrester Handover & Live Testing Technologies for Reliable Power Grid Operation
    1. Overview of Surge Arrester Handover Test Technology1.1 Necessity of Handover TestThe handover test is a crucial step in ensuring the performance and safe operation of surge arresters within power systems. For power systems with voltage levels at 220 kV and below, surge arresters play a core role in protecting electrical equipment from damage caused by overvoltages and lightning strikes. However, during the process from the arrester leaving the factory to its actual operation after installatio
    07/31/2025
  • Surge Arrester Failure Analysis and Prevention: Key Causes of 10 kV Distribution Arresters' Malfunctions
    1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
    07/30/2025
  • Advanced Online Monitoring System for Zinc Oxide Surge Arresters: Key Technologies and Fault Diagnosis
    1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer. Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source. Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs). Process Layer: Features monitoring terminals for Potential Transformers (PTs) a
    07/30/2025
  • Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
    1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
    07/30/2025
  • Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
    1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
    07/30/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.