LZZW-36 Outdoor Current Transformer

  • LZZW-36 Outdoor Current Transformer

Key attributes

Brand Wone Store
Model NO. LZZW-36 Outdoor Current Transformer
Rated voltage 33kV
Rated frequency 50/60Hz
Rated current ratio 300/5
Series LZZW

Product descriptions from the supplier

Description

Product Overview

Epoxy resin casting insulation and fully enclosed support construction, encloses the primary & secondary windings and annular core in the epoxy resin casting body. The product has large periphery insulation creepage distance, withstanding dirtiness and dampness. Be suitable for measuring electric capacity, current and protective relaying in the power system of 36kV (Up to 40.5 kV).

Key Features

  • 36kV-Class Outdoor High-Voltage Adaptation Design:The LZZW-36 outdoor current transformer is engineered with a 36kV rated voltage, achieving insulation levels of 95kV for lightning impulse and 50kV for power frequency withstand voltage. It strictly adheres to GB/T 4703.2 and IEC 60044-2 standards, optimized specifically for outdoor substations, box-type substations, overhead lines, and other scenarios operating at 35kV and below. Its structural design fully accounts for the long-term operational demands of high-voltage outdoor environments, effectively resisting voltage fluctuations and insulation aging to minimize equipment failure risks caused by insulation breakdown, ensuring stable operation of the power system.

  • All-Weather Protection Structure:This product features a dual-protection barrier composed of silicone rubber composite insulation materials and a corrosion-resistant aluminum alloy enclosure. It withstands 8,000 hours of UV aging testing, enduring prolonged outdoor exposure; achieves IP68 protection for continuous operation 1.5 meters underwater, while special structural designs resist 25mm/h snowfall and 15mm ice loads. Verified by 2,500 hours of salt spray testing, it offers a creepage distance of 25mm/kV, adapting to diverse harsh outdoor environments such as coastal areas, high-altitude regions, and cold zones, thereby reducing the impact of climatic factors on device performance.

  • Dual-Winding High-Precision Measurement System:Integrating a 0.2S-class metering winding and a 5P20-class protection winding, the metering winding maintains a ratio error ≤±0.2% within 1%–120% of rated current, meeting high-precision energy metering and line loss analysis requirements. The protection winding exhibits a composite error ≤5% at 20 times rated current with a response time ≤10ms, enabling rapid triggering of relay protection devices to ensure safe disconnection during grid faults. Equipped with two sets of ratio taps (e.g., 400/5A, 600/5A), adjustable via an outdoor-sealed switch without disassembly, it adapts flexibly to varying load currents, enhancing on-site application versatility.

  • Intelligent Monitoring & Multi-Mode Communication:Embedded with sensors for temperature (-40°C–+100°C), humidity, and insulation status, the device collects real-time operational data. It supports protocols such as Modbus RTU and IEC 61850-9-2 while retaining a 4–20mA analog output, enabling seamless integration into smart grid monitoring systems or compatibility with traditional monitoring equipment. Through edge computing modules, it locally analyzes data to remotely push early warnings for anomalies, reducing outdoor inspection frequency and operational costs—ideal for intelligent management of remote outdoor equipment.

Main technical parameter

  • Rated voltage: 30 kV or 33 kV or 34.5kV or 35kV etc

  • Rated secondary current:5Aor1A

  • Rated insulation level: 36/70/170 kV (40.5/95/200 kV)

  • Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers

Other technical parameter pls see as follow

Single ratio

Double ratio

Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.

Outline drawing

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Calibration Technology Challenges and Countermeasures for DC Electronic Current Transformers
    In modern power systems, DC electronic current transformers play a crucial role. They are not only used for high-precision current measurement but also serve as key tools for grid optimization, fault detection, and energy management. With the rapid development of high-voltage direct current (HVDC) transmission technology and its widespread deployment globally, the performance requirements for DC current transformers have become increasingly stringent, especially in terms of measurement accuracy
    07/23/2025
  • Performance Structure and Testing of Electronic Current Transformers
    1 Performance AdvantagesIn recent years, electronic current transformers (ECTs) have emerged as a key industry trend. National standards classify them into two types: Active Optical Current Transformers (AOCTs, active hybrid type) and Optical Current Transformers (OCTs, passive optical type). Active hybrid ECTs use low-power electromagnetic transformers and Rogowski coils as core sensing elements (Figure 1).Rogowski coils outperform traditional sensors with non-saturation and wide dynamic ranges
    07/22/2025
  • Principles Faults and Online Diagnosis of Electronic Current Transformer Secondary Circuits
    1 Principle and Role of Electronic Current Transformers1.1 Working Principle of ECTAn Electronic Current Transformer (ECT) is a key device for managing safe power system operations, converting large currents into manageable small-current signals for measurement and control. Unlike traditional transformers (relying on direct magnetic field interaction between primary and secondary windings), ECTs use sensors (e.g., Hall effect sensors) to detect magnetic field changes from the primary winding. Th
    07/22/2025
  • Key Technologies and Challenges of High-Voltage Electronic Transformers
    Traditional power transformers face inherent issues due to their sensors. Critically, they are vital for power plant monitoring, control, and protection (e.g., fault recording, safety control). However, large electrical energy transmission via information carriers and the lack of digital signal output from digital systems complicate secondary communication. Complex secondary wiring compensates for microcomputers’ high reliability, streamlining protection and secondary devices. This inn
    07/22/2025
  • What Are the Common Faults of Low-Voltage Voltage Transformers and Their Solutions?
    Open - Circuit Fault on the Secondary SideOpen - circuit in the secondary side is a typical fault of low - voltage voltage transformers, showing abnormal voltmeter readings (zero/fluctuation), faulty power meters, buzzing noises, and core overheating. When open - circuited, the secondary voltage spikes (no secondary current to balance the primary EMF), causing core saturation, flux distortion, and potential overheating/damage.Causes include loose terminals, poor contact, or human error. In low
    07/18/2025
  • Impact of Long-Term Immersion on Epoxy-Insulated Low-Voltage Current Transformers
    1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
    07/17/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.