| Brand | Switchgear parts |
| Numero ng Modelo | Mataas na peryodyong online na suplay ng kuryente (Single phase/220V) |
| Larawan na Pagsasahimpapawid | 50/60Hz |
| Lalabas na voltaje | 200-240VAC |
| Kapasidad | 1kVA |
| Serye | HBG |
Ang serye ng HBG ay lubos na kumakatawan sa esensya ng cutting-edge technology. Ang buong makina ay gumagamit ng pinakamaunlad na DSP digital control technology at ultra-high frequency control technology sa buong mundo upang lumikha ng maliit na sukat, magaan na timbang, at mataas na efficiency sa trabaho; zero conversion design at dalisay na sine wave ang teknolohiya ng output na nagagarantiya na ang device ng user ay angkop para sa iba't ibang uri ng device. Ginagamit ang isang natatanging AC-DC conversion circuit upang masuri ang output current at output voltage ng commercial power supply, at sa pamamagitan ng high-frequency pulse width modulator, ang current waveform ng input power supply ay pareho sa phase ng voltage waveform, upang makamit ang mataas na input power factor na higit sa 95%. Sa ilalim ng normal na kondisyon ng mains, kinukuha ng mains ang DCBUS DC voltage sa pamamagitan ng Ac-Dc circuit, at pagkatapos ay ginagawa ang conversion ng DCBUS patungo sa 220V AC output sa pamamagitan ng inverter. wave power. Ang mahusay na IGBT ay ginagamit bilang elemento ng power conversion. Dahil sa mataas na frequency switching characteristics ng IBGT, ang operating frequency ng UPS inverter ay maaaring umabot sa 40KHz. Napabuti ang working efficiency ng inverter, at napabuti rin ang efficiency ng UPS. Nabawasan ang ingay ng inverter, kaya ang HBG series UPS ay maaaring direktang mailagay sa computer room nang hindi nakakaapekto sa iyong trabaho. online high-frequency HBG series UPS sa pamamagitan ng RS232 flood interface kasama ang power monitoring software, konektin ang UPs sa network server. magbigay ng status ng power anumang oras: at maisakatuparan ang timing self-check, awtomatikong storage, awtomatikong timing switch machine at i-record ang power Status at iba pang mga intelligent function upang makamit ang zero distance sa pagitan ng tao at makina komunikasyon, Kapag nawala ang utility power, abisuhan ng UPS ang server na maghanda para sa shutdown, awtomatikong i-save ang lahat ng data sa disk, at isagawa ang normal na shutdown command. Kahit sa isang walang tao na network environment, mapangangalagaan ang seguridad ng data ng network system.
Pangunahing Katangian
Tunay na Online Double Conversion
Koreksyon ng Input Power Factor
Output Power Factor hanggang 0.8
Ultra-wide Mains Input Range (110V-300V)
Modo ng Efficient Frequency Conversion OEcO nagbibigay ng epekto ng pag-iipon ng enerhiya (para lamang sa mga modelo 1-3K)
Compatible na Generator Input
Mahabang panahon na Charging Current hanggang 6A
Opsyunang matalinong SNMP card na maaaring gamitin nang mag-isa o kasama ang USB
Perpektong Monitoring gamit ang RS232
Simple na Operation Control sa pamamagitan ng Display
At komprehensibong Display Monitoring ng Status ng UPS
Pamantayan ng aplikasyon
Malawakang ginagamit sa mga mahalagang patlang ng datos tulad ng mga sentro ng pamamahala ng network at computer, bangko at securities, buwis, komunikasyon, serbisyo postal, broadcasting at telebisyon, seguridad pampubliko, transportasyon, kuryente, pangangalaga ng kalusugan, industriyal na kontrol, at pambansang depensa.
Teknikal na mga Parametro
| Model Specification | HBG-1kH(S) | HBG-2kH(S) | HBG-3kH(S) | HBG-6kH(S) | HBG-10kH(S) |
|---|---|---|---|---|---|
| Phase | Single Phase Input and Output | ||||
| Capacity | 1000 VA / 800 W | 2000 VA / 1600 W | 3000 VA / 2400 W | 6000 VA / 4800 W | 10000 VA / 8000 W |
| Input | |||||
| Voltage Range | 110 - 300VAC at 50% load; 160 - 300 VAC at 100% load | 110 - 300VAC at 50% load; 176 - 300 VAC at 100% load | |||
| Frequency Range | 40Hz ~ 70 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz | |||
| Power Factor | ≥ 0.99 at 100% load | ≥ 0.99 at 100% load | |||
| Output | |||||
| Output Voltage | 200/208/220/230/240VAC | 208/220/230/240VAC | |||
| Voltage Range (Battery Mode) | ± 1% | ± 1% | |||
| Frequency Range (Synchronous Correction Range) | 47 ~ 53 Hz or 57 ~ 63 Hz | 46Hz ~ 54 Hz or 56Hz ~ 64 Hz | |||
| Frequency Range (Battery Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | |||
| Crest Factor | 3:1 | 3:1 | |||
| Ripple Distortion | ≤ 3% THD (Linear Load); ≤6% THD (Non-linear Load) | ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load) | |||
| Harmonic Distortion | 0 | 0 | |||
| Conversion Time | |||||
| AC to DC | 4 ms (Standard Conditions) | 0 | |||
| Inverter to Bypass | |||||
| Waveform (Battery Mode) | Pure Sine Wave | ||||
| Efficiency | |||||
| Mains Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 89% | 89% | 91% |
| Battery | |||||
| Standard Unit | |||||
| Battery Model | 12V / 7AH | 12V / 7AH | 12V / 7AH | 12V / 7AH | 12V / 7AH |
| Quantity (Cells) | 2 | 4 | 6 | 12 | 16 |
| Maximum Charging Current | 1.0A (Max) | 1.0A (Max) | 1.0A (Max) | Preset:1.0 A, Max:2.0A | Preset:1.0 A, Max:2.0A |
| Charging Voltage | 27.3VDC ± 1% | 54.7VDC ± 1% | 82.1VDC ± 1% | 163.8VDC ± 1% | 218.4VDC ± 1% |
| Long-term Unit | Depends on Power Supply Time | ||||
| Battery Model | 6 | 6 | 16 | 16 | |
| Quantity (Cells) | 3 | 6 | 8 | 16 | 16 |
| Maximum Charging Current | 1.0A/2.0A/4.0A/6.0 A | 1.0A/2.0A/4.0A/6.0 A | 1.0A/2.0A/4.0A/6.0 A | Preset:4.0 A ± 10%, Max:6.0A ± 10% | Preset:4.0 A ± 10%, Max:6.0A ± 10% |
| Charging Voltage | 41.0VDC ± 1% | 82.1VDC ± 1% | 109.4VDC ± 1% | 218.4VDC ± 1% | 218.4VDC ± 1% |
| Appearance | |||||
| LCD or LED Display | Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication | ||||
| Alarm | |||||
| Battery Mode | Beeps every 4 seconds | ||||
| Low Battery | Beeps every 1 second | ||||
| Overload | Beeps every 0.5 second | ||||
| Error | Continuous Beep | ||||
| External Dimensions | |||||
| Standard Unit | |||||
| Dimensions (W×D×H)mm | 145 X 282 X 220 | 145 X 397 X 220 | 190 X 421 X 318 | 190 x 369 x 688 | 190 x 442 x 688 |
| Net Weight (kgs) | 9.8 | 17 | 27.6 | 43 | 63 |
| Long-term Unit | |||||
| Dimensions (W×D×H)mm | 145 X282 X 220 | 145 X397 X 220 | 190 x369 x 318 | 190 x442 x 318 | |
| Net Weight (kgs) | 4.1 | 6.8 | 7.4 | 12 | 16 |
| Operating Environment | |||||
| Temperature and Humidity | Relative Humidity 20-90% and Temperature 0-40°C (No Condensation) | Relative Humidity 0-95% and Temperature 0-40°C (No Condensation) | |||
| Noise | Less than 50dB@ 1m | Less than 55dB @ 1m | |||
| Control Management | |||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC | ||||
| Optional SNMP | Power Management Supports SNMP Management and Network Management |
Kapag ang UPS ay naka-setting sa mode ng constant voltage at frequency, ang output power ay magiging derated ng 40%. Kapag ang output voltage ng UPS ay naka-setting sa 208VAC, ang output power ay magiging derated ng 10%. Ang "S" ay kumakatawan sa long-life model. Kapag ang bilang ng internal battery ay binago sa 16-19 units, ang makina ay derate ang output batay sa sumusunod na formula: P=Prating × (N/20 × 100%). Kung ang makina ay i-install sa altitude na lumampas sa 1,000 meters, ang output power ay magiging derated ng 1% para sa bawat 100-meter increase sa elevation. Anumang pagbabago sa current product specifications ay hindi magiging separately notified
Sundin ang mga sumusunod na pagsasadya sa kaligtasan upang iwasan ang mga aksidente at pagkasira ng kagamitan: ① Pagsasala ng pagkakabagabag ng kuryente: Huwag hawakan ang mga komponente sa loob ng UPS nang ito ay naka-on; panatilihin ang UPS malayo sa mga bata upang iwasan ang aksidental na paghawak sa mga tuklukan; ② Pagsasala ng sunog: Huwag ilagay ang mga matutulak na materyales (hal. papel, tela) paligid ng UPS; huwag hadlangin ang mga butas ng paglabas ng init upang iwasan ang sobrang init at sunog; ③ Kaligtasan ng baterya: Huwag ikonekta ang mga terminal ng baterya; huwag buksan o sunugin ang baterya (may panganib ng pagputok); itapon ang mga lumang baterya ayon sa lokal na regulasyon sa kapaligiran (huwag itapon sa normal na basura); ④ Paggamit sa emergency: Kung may usok, amoy, o hindi normal na ingay mula sa UPS, agad na tanggalin ito mula sa main power at ikumpuni ang baterya; makipag-ugnayan sa serbisyo pagkatapos ng benta para sa pagrerepaso (huwag subukan pang magrepara nang sarili); ⑤ Kaligtasan sa paglipad: Kapag inililipat ang UPS, iwasan ang pagbagsak o paghila-hila nito nang malakas; para sa mga modelo na may built-in na baterya, sundin ang mga regulasyon sa paglipad/sa lupa para sa lithium/lead-acid na baterya.
Ito ay isang kompak na uninterruptible power supply na disenyo para sa mga senaryo ng single-phase grid at single-phase load, pangunahing ginagamit upang maprotektahan ang mga office computers, monitoring systems, home electronics, at maliit na mga server. Pangunahing mga punsiyon: ① Magbigay ng walang pagkakatiilang suplay ng kuryente sa panahon ng mga pagkawala ng kuryente sa grid (switching time <2ms) upang maiwasan ang pagkawala ng datos o pag-off ng mga equipment; ② I-stabilize ang voltage, i-filter ang harmonics, at i-suppress ang mga surge upang mailayo ang mga anomalya sa grid (halimbawa, voltage spikes, brownouts); ③ Siguraduhing may pure sine wave output para sa mga sensitibong equipment. Paraan ng paggana: Gumagamit ng high-frequency double-conversion technology (20kHz–50kHz)—single-phase AC input ay inu-rectify sa DC power, pagkatapos ay inu-invert sa stable single-phase AC output. Kapag nawala ang main power, ang built-in/external battery ay agad nagbibigay ng DC power sa inverter, na nagpapatupad ng zero-interruption power supply. Ang kanyang high-frequency design ay gumagawa nito mas maliit, mas magaan, at mas energy-efficient kaysa sa mga tradisyonal na low-frequency UPS.