| Brand | ROCKWILL | 
| Numero sa Modelo | High - voltage pneumatic load break switch Tagabigay ng High - voltage na load break switch nga gamit ang hangin | 
| Naka nga boltahang rated | 12kV | 
| Rated Current | 630A | 
| Nasodnong peryedyo | 50/60Hz | 
| Serye | FKN | 
Product Overview
Ang mataas na bolteheng pneumatic load break switches ug ang ilang gipiling electrical appliances mao ang indoor high - voltage switchgear para sa AC 12kV, 50Hz. Kini nga load break switch adunay mataas nga espesipikong teknikal nga mga parametro ug reliable nga pag-act. Ang basic form sa operating mechanism mao ang manual spring-energy-storage type, ug mahimo usab kini nga i-equip uban sa electromagnetic spring operating mechanism. Batasan sa pneumatic arc-extinguishing principle, mahimo kini nga mag-interrupt og daghan ka beses nang walay pagbag-o sa arc-extinguishing tube.
Ang mataas na bolteheng load break switch mahimo mog-close, carry, ug open sa load currents sa normal nga circuit conditions, ug adunay kapabilidad sa pag-close ug pag-open sa short-circuit currents sa maespesifiko nga short time.
Ang load break switches mahimo mog-equip uban sa earthing switches. Ang earthing switch adunay sama nga short-circuit making capacity sa load break switch, kasama ang dynamic ug thermal stability capability, ug adunay strict nga mechanical interlock sa load break switch, nag-siguro nga dili posible ang misoperation sa structure.
Key Features
Kung ang FKN12-12 load break switch gi-equip uban sa high-voltage current-limiting fuse (uban sa striker) aron makabuo og load break switch-fuse combination, kini nagserbisyo isip overload ug short-circuit protection alang sa loads (tulad sa power transformers). Kung usa o daghan pa nga phases sa fuse mog-blow, ang tatlo nga phases sa load break switch awtomatiko mog-open.
Ang mataas na bolteheng load break switch suitable sa pag-install sa ring-main unit switch cabinets ug uban pang types sa switch cabinets alang sa pag-receive ug pag-distribute sa electrical energy.
Technical Parameters
Serial No.  |  
   Name  |  
   Unit  |  
   Value  |  
  
1  |  
   Rated Voltage  |  
   KV  |  
   12  |  
  
2  |  
   Rated Frequency  |  
   Hz  |  
   50  |  
  
3  |  
   Rated Current  |  
   A  |  
   630  |  
  
4  |  
   Maximum Rated Current of Fuse  |  
   A  |  
   100  |  
  
5  |  
   Rated Active Load Breaking Current, Rated Closed-loop Breaking Current  |  
   A  |  
   630  |  
  
6  |  
   Rated Short-time Withstand Current (2S)  |  
   KA  |  
   20  |  
  
7  |  
   Rated Short-circuit Making Current, Rated Peak Withstand Current  |  
   KA  |  
   50  |  
  
8  |  
   1min Power Frequency Withstand Voltage, Phase-to-phase and to-ground / Break  |  
   KV  |  
   42/48  |  
  
9  |  
   Lightning Impulse Withstand Voltage (Peak Value), Phase-to-phase and to-ground / Break  |  
   KV  |  
   75/85  |  
  
10  |  
   Rated Cable Charging Breaking Current  |  
   A  |  
   10  |  
  
11  |  
   Rated Breaking of No-load Transformer  |  
   KVA  |  
   1250  |  
  
12  |  
   Mechanical Life  |  
   Times  |  
   2000  |  
  
13  |  
   Rated Breaking Transfer Current  |  
   A  |  
   1150  |  
  
14  |  
   Rated Short-circuit Breaking Current of Fuse  |  
   KA  |  
   31.5  |  
  
Main Mechanical Characteristics of Load Break Switch
Serial No.  |  
   Name  |  
   Unit  |  
   Value  |  
   Remarks  |  
  
1  |  
   Phase-to-phase Center Distance  |  
   mm  |  
   210 ± 3  |  
   |
2  |  
   Total Stroke of Conductive Rod  |  
   mm  |  
   215 ± 5  |  
  |
3  |  
   Distance Between Moving and Static Arc at Opening Position  |  
   mm  |  
   >160  |  
  |
4  |  
   Over-stroke of Electrical Contact of Moving Contact Rod  |  
   mm  |  
   42 ± 3  |  
  |
5  |  
   Just-Closing Speed  |  
   m/s  |  
   3.8 <sup>+0.7</sup><sub>-0.2</sub>  |  
  |
6  |  
   Just-Opening Speed  |  
   m/s  |  
   >2.7  |  
  |
7  |  
   Three-phase Closing Asynchronism  |  
   ms  |  
   >10  |  
   Contact between moving contact rod and contact fingers  |  
  
8  |  
   Three-phase Opening Asynchronism  |  
   ms  |  
   >5  |  
   Separation between moving contact rod and contact fingers  |  
  
Altitude: Dili mosobra sa 1000m.
Ambient Temperature: Maximum +40°C, Minimum -10°C.
Relative Humidity: Daily average dili mosobra sa 95%, Monthly average dili mosobra sa 90%.
Seismic Intensity: Mas gamay sa 8 degrees.