| Brand | ROCKWILL |
| Numero sa Modelo | High - voltage pneumatic load break switch Tagabigay ng High - voltage na load break switch nga gamit ang hangin |
| Naka nga boltahang rated | 12kV |
| Rated Current | 630A |
| Nasodnong peryedyo | 50/60Hz |
| Serye | FKN |
Product Overview
Ang mataas na bolteheng pneumatic load break switches ug ang ilang gipiling electrical appliances mao ang indoor high - voltage switchgear para sa AC 12kV, 50Hz. Kini nga load break switch adunay mataas nga espesipikong teknikal nga mga parametro ug reliable nga pag-act. Ang basic form sa operating mechanism mao ang manual spring-energy-storage type, ug mahimo usab kini nga i-equip uban sa electromagnetic spring operating mechanism. Batasan sa pneumatic arc-extinguishing principle, mahimo kini nga mag-interrupt og daghan ka beses nang walay pagbag-o sa arc-extinguishing tube.
Ang mataas na bolteheng load break switch mahimo mog-close, carry, ug open sa load currents sa normal nga circuit conditions, ug adunay kapabilidad sa pag-close ug pag-open sa short-circuit currents sa maespesifiko nga short time.
Ang load break switches mahimo mog-equip uban sa earthing switches. Ang earthing switch adunay sama nga short-circuit making capacity sa load break switch, kasama ang dynamic ug thermal stability capability, ug adunay strict nga mechanical interlock sa load break switch, nag-siguro nga dili posible ang misoperation sa structure.
Key Features
Kung ang FKN12-12 load break switch gi-equip uban sa high-voltage current-limiting fuse (uban sa striker) aron makabuo og load break switch-fuse combination, kini nagserbisyo isip overload ug short-circuit protection alang sa loads (tulad sa power transformers). Kung usa o daghan pa nga phases sa fuse mog-blow, ang tatlo nga phases sa load break switch awtomatiko mog-open.
Ang mataas na bolteheng load break switch suitable sa pag-install sa ring-main unit switch cabinets ug uban pang types sa switch cabinets alang sa pag-receive ug pag-distribute sa electrical energy.
Technical Parameters
Serial No. |
Name |
Unit |
Value |
1 |
Rated Voltage |
KV |
12 |
2 |
Rated Frequency |
Hz |
50 |
3 |
Rated Current |
A |
630 |
4 |
Maximum Rated Current of Fuse |
A |
100 |
5 |
Rated Active Load Breaking Current, Rated Closed-loop Breaking Current |
A |
630 |
6 |
Rated Short-time Withstand Current (2S) |
KA |
20 |
7 |
Rated Short-circuit Making Current, Rated Peak Withstand Current |
KA |
50 |
8 |
1min Power Frequency Withstand Voltage, Phase-to-phase and to-ground / Break |
KV |
42/48 |
9 |
Lightning Impulse Withstand Voltage (Peak Value), Phase-to-phase and to-ground / Break |
KV |
75/85 |
10 |
Rated Cable Charging Breaking Current |
A |
10 |
11 |
Rated Breaking of No-load Transformer |
KVA |
1250 |
12 |
Mechanical Life |
Times |
2000 |
13 |
Rated Breaking Transfer Current |
A |
1150 |
14 |
Rated Short-circuit Breaking Current of Fuse |
KA |
31.5 |
Main Mechanical Characteristics of Load Break Switch
Serial No. |
Name |
Unit |
Value |
Remarks |
1 |
Phase-to-phase Center Distance |
mm |
210 ± 3 |
|
2 |
Total Stroke of Conductive Rod |
mm |
215 ± 5 |
|
3 |
Distance Between Moving and Static Arc at Opening Position |
mm |
>160 |
|
4 |
Over-stroke of Electrical Contact of Moving Contact Rod |
mm |
42 ± 3 |
|
5 |
Just-Closing Speed |
m/s |
3.8 <sup>+0.7</sup><sub>-0.2</sub> |
|
6 |
Just-Opening Speed |
m/s |
>2.7 |
|
7 |
Three-phase Closing Asynchronism |
ms |
>10 |
Contact between moving contact rod and contact fingers |
8 |
Three-phase Opening Asynchronism |
ms |
>5 |
Separation between moving contact rod and contact fingers |
Altitude: Dili mosobra sa 1000m.
Ambient Temperature: Maximum +40°C, Minimum -10°C.
Relative Humidity: Daily average dili mosobra sa 95%, Monthly average dili mosobra sa 90%.
Seismic Intensity: Mas gamay sa 8 degrees.