• DS4C 252kV High voltage disconnect switch
DS4C 252kV High voltage disconnect switch
discuss personally
Model
DS4C-252/4000-50
DS4C-252/3150-50
DS4C-252/2500-50
DS4C-252/1600-50
Basic info
Brand ROCKWILL
Model NO. DS4C 252kV High voltage disconnect switch
Rated voltage 252kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series DS4C
Product Detail

Product introduction:

GW4C Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs Is changed. In addition, It can be used lo exercise safe electrical insulation for such HV electric apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product has two insulators with horizontal center breaks. It Is openable In the middle and accessible to the grounding switch on one side or two sides. The disconnect switch adopts CS14G or CS11 manual operating mechanism or CJ2 motor-based operating mechanism to realize the tri-pole linkage,The earthing switch adopts CS14G manual operating mechanism to actual亿e tri-pole linkage

This product has been verified by the Chinese competent authority as having uniqueness in design and reaching intonational advanced level of similar products.

GW4C disconnect switch comprises three single poles and operating mechanism. Each single pole is made of a base, post insulator and conductive part revoting insulating posts are mounted at both sides of a long base. The conductive switch blade's contact arms are respectively fixed at the tops of the insulating posts.

When the Insulating post at one end of the actuator revolves to drive, and through the cross-over lever, brings the insulating post at the other end to rotate reversely by 90° to make the conductive switch blade circumgyrate. In this way, the isolating switch is opened and closed.

Main characteristic:

  • The conductive arm made of rectangular Al-alloy pipes is characterized by high strength, light weight targe radiation area and strong stance against corruption
  • The finger is made of pure copper and has a silver plating process. It has strong now capacity and long mechanical life. The stamping process ensures the reliability of contact and finger contact.
  • The contact finger pressure is prohormonal to the primary insertion depth of the contact, the sensitivity is low, the contact insertion area is long, the on-site debugging is difficult, and the product is highly reliable against adverse interference such as harsh environment (winding of the flexible wire).
  • The contact Is made of curved copper plate. In the opening and closing processes, there is a short trip of friction between the contact and the finger and the required operating force is small.
  • The rotating parts of the Switch Disconnector are designed to be free of any maintenance. The rotating base is designed into a closure structure which denies t沺access of moisture, dust and harmful gases so that the low-temperature lubricating cream within the bearing will not run off or harden.
  •  Provide one-key sequential control "double confirmation" function expansion

Main technical parameters:

GW4C-parameters.png

 Order notice: 

Product model, rated voltage, rated current, Rated short-time withstand current and creepage distance must be specified at the goods-ordering time.

The disconnect switch offers several options of grounding (Left, right, both left and right).Unless otherwise specified, the goods supplied will be considered as providing the option of right grounding;

Note:

  • The methods of judging left end right grounding: hold out both arms and keep the arms in the same direction as the disconnect switch is opened. The earthing switch will be considered as left grounding non the left hand side, and right grounding if on the right hand side;
  • The operating mechanism, motor voltage, control voltage and the number of contacts for auxiliary switch;
  • When the Switch Disconnector is used at the incoming and outgoing terminals of the substation in the double loop parallel overhead power transmission line, if the earthing switch requires the opening/dosing induction current then such requirement shall be specified. Besides, the parameters and the side at which the earthing switch Is set shall be defined. (Special notice: Not all earthing switches attached to the earthing switches and disconnect switches at the substation shall require the opening/closing Induction current)

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
What Is An Inverter-integrated Transformer?
What Is An Inverter-integrated Transformer?
An inverter-integrated transformer is a power conversion device that combines the functions of an inverter and a transformer into a single unit. Widely utilized in renewable energy systems such as solar photovoltaic (PV) and wind power generation, its primary role is to convert direct current (DC) to alternating current (AC) while adjusting voltage levels (stepping up or down) via the transformer, ensuring compatibility with grid requirements or specific load demands.1. Basic Functions and Opera
Vziman
07/31/2025
Estimation of capacitive current
Estimation of capacitive current
The capacitive current is mainly determined by the length of the feeder, the cross-sectional area of the conductor, the dielectric constant, the height above the ground, and the rated voltage. The specific estimation methods are as follows:Estimation of capacitive current of overhead lines: For overhead lines of 3 - 35 kV, the capacitance per phase to ground is usually 5000 - 6000 pF/km. Based on this, the value of the single-phase grounding capacitive current per kilometer for lines of differen
Leon
07/31/2025
What are the technical characteristics of hydrogen-cooled power transformer technology?
What are the technical characteristics of hydrogen-cooled power transformer technology?
Power transformers are pivotal components in electrical grids, tasked with voltage conversion to enable efficient electricity transmission and distribution. As global energy demands surge and grid architectures grow increasingly complex, there is an urgent need for advanced transformer technologies that enhance efficiency, minimize environmental impact, and ensure operational reliability. Among emerging innovations, hydrogen-cooled power transformer technology has emerged as a particularly promi
Edwiin
07/31/2025
What are the basic knowledge points about transformer bushings?
What are the basic knowledge points about transformer bushings?
1. Functions of Transformer BushingsThe core function of transformer bushings is to lead the coil leads out to the external environment. They serve both as insulating components between the leads and the oil tank and as fixing devices for the leads.During the operation of a transformer, bushings continuously carry load currents and, in the event of an external short circuit, withstand short-circuit currents. Therefore, transformer bushings must meet the following requirements:Possess specified e
Rockwell
07/31/2025
What are the application scenarios of power transformers with a rating above 10kV?
What are the application scenarios of power transformers with a rating above 10kV?
High - voltage power transformers (above 10 kV) are extensively applied in various sectors, spanning residential and industrial fields. The following is a detailed overview of their main application scenarios and technical characteristics:1. Urban and Civil Applications1.1 Residential Communities and Commercial CentersThe 10 kV - rated combination transformer, favored for its compact size and fully sealed structure, is widely used in new residential complexes, shopping centers, and high - rise b
Vziman
07/31/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!