High voltage disconnect switch with Anti-Corrosion Technology DS23B 126kV 145kV 225kV 230kV 252kV 363kV 420kV 550kV

  •  High voltage disconnect switch with Anti-Corrosion Technology DS23B 126kV 145kV 225kV 230kV 252kV 363kV 420kV 550kV

Key attributes

Brand ROCKWILL
Model NO. High voltage disconnect switch with Anti-Corrosion Technology DS23B 126kV 145kV 225kV 230kV 252kV 363kV 420kV 550kV
Rated voltage 550kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS23B
Description

Product Introduction

We are a source factory specializing in high-voltage disconnectors. The high-voltage disconnect switch (Model: DS23) is an outdoor three-phase AC equipment, applicable to 50Hz/60Hz power systems. It is mainly used for breaking or connecting no-load high-voltage lines, providing safe insulation and stable power transmission.
This high-voltage disconnect switch adopts a double-post horizontal telescopic structure with plug-type contacts, forming a reliable insulating break when opened. It is suitable for 110kV-550kV power systems, and can be equipped with an earthing switch to enhance operational safety.
The high-voltage disconnect switch is easy to install and maintain, with stable performance and strong environmental adaptability. It has passed strict quality verification, meeting international industry standards, and can be customized according to actual project needs.

Main Features

  • The conductive parts adopt high-conductivity aluminum alloy, featuring good electrical conductivity, high mechanical strength, light weight and strong corrosion resistance, ensuring stable current transmission and long-term reliable operation of the high-voltage disconnect switch.
  • The disconnect switch adopts a single-arm foldable telescopic structure, with driving components and balance springs sealed in the conductive tube, which is not affected by the external environment and has a compact and simple appearance.
  • The plug-type contact of the high-voltage disconnect switch has self-cleaning performance, and the contact pressure is stable. When short-circuit current passes through, the contact clamping force will automatically increase, ensuring reliable contact and strong short-circuit current bearing capacity.
  • The disconnect switch supports one-key sequential control "double confirmation" function expansion, which is convenient for intelligent operation and management.

Main technical parameters

   Among these voltage levels126kV-765kV non-standard custom manufacturing disconnector switch , the rated short-circuit breaking current is 63kA, and customization is available.

NO

Specifications

Unit

Value

1

Product model

 

DS23B-126D

DS23B- 145D

DS23B - 252D

DS23B- 363D

DS23B - 420D

DS23B - 550D

2

Rated voltage

kV

126

145

252

363

420

550

3

1min power frequency withstand voltage (r.m.s)

 

Phase to phase to earth

kV

230

275

460

510

520

740

Across isolating distance

kV

230 (+70)

315

460 (+145)

510 (+210)

610

740 (+318)

4

Lightning impulse withstand voltage(peak 1.2/50μs)

Phase to phase to earth

kV

550

650

1050

1175

1425

1675

Across isolating distance

kV

550 (+100)

750

1050

1175 (+200)

1425 (+295)

1675 (+450)

5

Rated frequency

HZ

50/60

50/60

50/60

50/60

50/60

50/60

6

Rated current

A

2000/3150/4000

2500

2000/2500/3150/4000/5000

4000/5000

3150

4000/5000

7

Rated short - time withstand current (r.m.s)

kA

50

50

50/63

63

63

63

8

Rated peak withstand current

kA

125

125

125/160

160

160

160

9

Rated short - circuit withstand time

S

3

3

3

3

2

3

10

Wiring terminal static mechanical load

Longitudinal

N

1250

1250

2000

2500

4000

4000

Horizontal

N

750

800

1500

2000

1600

2000

Vertical

N

1000

1000

1250

2000

1500

2000

11

Creepage distances

mm

3150, 3906

3625, 4495

6300, 7812

9450

10500, 13020

17050

12

Mechanical life

Times

10K

10K

13

Motor operating mechanism

Model

SRCJ7

SRCJ7

SRCJ3

SRCJ2

14

Motor voltage

V

AC380/DC220

15

Control circuit's voltage

V

AC220/DC220/DC110

16

Opening/closing time

S

12±1

16±1

17

Manual operating mechanism

Model

SRCS

 

18

Electromagnetic lock's voltage

V

AC220/DC220/DC110

     

Order notice 

  • Product model, rated voltage, rated current, rated short-time withstand current and creepage distance must be specified at the goods-ordering time;
  • It can be decided whether a earthing switch should be attached to the switch disconnector;
  • It must be decided whether the upper bus line of the switch disconnector is soft or hard. Additionally, the external diameter of the tubular busbar shall be specified;
  • It must be decided whether the disconnect switch is arranged in cross-over or parallel form;
  • The actuator's model, motor's voltage, control voltage and the number of contacts for auxiliary switch.

FAQ for High voltage disconnect switch

Q: Which manufacturer models are recommended for 500kV substation projects?
A:

For 500kV substation projects, the following high-performance disconnectors are recommended:

  • Rockwill Electric: DS23B-550D/5000, offering high cost-effectiveness with high rated current, strong withstand capability, long mechanical lifespan, and reliable insulation performance, suitable for stable operation in high-voltage scenarios.

  • Pinggao Electric: GW27-550(W)/4000, suitable for high-current applications with excellent pollution resistance.

  • China XD Electric: GW28-550/4000, featuring a robust structure and adaptability to high voltage levels.

  • Siyuan Electric: GW28-G-550/4000, an improved design with optimized transmission mechanisms for enhanced operational reliability.

  • Shandong Taikai: GW27-550(W)/4000, providing cost-effectiveness and extensive engineering application support.

Comparison Points:

  • Rated Current: All recommended models support 4000A (except Rockwill's 5000A), meeting the requirements of 500kV substations.

  • Environmental Adaptability: The "W" suffix in Pinggao and Taikai models indicates specialized suitability for heavily polluted areas.

  • Intelligent Features: The "G" suffix in Siyuan products denotes support for advanced smart monitoring functions.

Q: For a 110kV system whose main wiring adopts a sectionalized single busbar with a bypass circuit breaker, which of the following statements about the interlocking of the bypass disconnector is correct?
A:
  • The earthing switch on the bypass bus side of the bypass circuit must be operable only when the disconnector on the bypass bus side of the bypass circuit breaker is open.
  • The bypass bus disconnector of the circuit breaker must be operable only when the circuit breaker is open and the sectionalizing disconnector connecting the disconnector to the busbar is open.
Q: 225kV/230kV/245kV all fall into the medium-high voltage category. What are their core differences?
A:

The main differences lie in rated voltage calibration and insulation level requirements. 245kV is closer to the standard 252kV class, while 225kV/230kV are mostly customized for regional needs to match specific power grid loads.

Know your supplier

Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m² Total staff: 700+ Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Related Products
Related Knowledges
  • Installation Requirements and Procedures for 10 kV High-Voltage Disconnect Switches
    First, the installation of 10 kV high-voltage disconnect switches must meet the following requirements. The first step is to select an appropriate installation location, typically near the switchgear power supply in the power system to facilitate operation and maintenance. At the same time, sufficient space must be ensured at the installation site to accommodate equipment placement and wiring.Secondly, equipment safety must be fully considered—for example, lightning protection and explosion-proo
    11/20/2025
  • Common Issues and Handling Measures for 145kV Disconnector Control Circuits
    The 145 kV disconnector is a critical switching device in substation electrical systems. It is used in conjunction with high-voltage circuit breakers and plays an important role in power grid operation:First, it isolates the power source, separating equipment under maintenance from the power system to ensure personnel and equipment safety;Second, it enables switching operations to change the system operating mode;Third, it is used to interrupt small-current circuits and bypass (loop) currents.Re
    11/20/2025
  • What are the six operating principles of disconnect switches?
    1. Operating Principle of the DisconnectorThe operating mechanism of the disconnector is connected to the active pole of the disconnector via a connecting tube. When the main shaft of the mechanism rotates 90°, it drives the insulating pillar of the active pole to rotate 90°. The bevel gears inside the base drive the insulating pillar on the other side to rotate in the opposite direction, thereby achieving opening and closing operations. The active pole, through inter-pole linkage tubes, drives
    11/19/2025
  • 36kV Disconnect Switch Selection Guide & Key Parameters
    Selection Guidelines for 36 kV Disconnect SwitchesWhen selecting the rated voltage, ensure that the disconnect switch’s rated voltage is equal to or higher than the nominal voltage of the power system at the installation point. For example, in a typical 36 kV power network, the disconnect switch must have a rated voltage of at least 36 kV.For rated current, selection should be based on the actual long-term load current. Generally, the switch’s rated current must be no less than the maximum conti
    11/19/2025
  • Copper Conductor Size vs Temperature Rise in 145kV Disconnectors
    The relationship between the temperature-rise current of a 145 kV disconnector and copper conductor size lies in balancing current-carrying capacity and heat dissipation efficiency. The temperature-rise current refers to the maximum continuous current a conductor can carry without exceeding its specified temperature rise limit, and the copper conductor size directly influences this parameter.Understanding this relationship begins with the physical properties of the conductor material. Copper’s c
    11/19/2025
  • Design of an Intelligent Control System for Fully Enclosed Disconnectors in Distribution Lines
    Intelligentization has become an important development direction for power systems. As a critical component of the power system, the stability and safety of 10 kV distribution network lines are vital to the overall operation of the power grid. The fully enclosed disconnector, as one of the key devices in distribution networks, plays a significant role; thus, achieving its intelligent control and optimized design is of great importance for enhancing the performance of distribution lines.This pape
    11/17/2025
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.