• GW4 Series HV disconnector
  • GW4 Series HV disconnector
  • GW4 Series HV disconnector
  • GW4 Series HV disconnector
GW4 Series HV disconnector
discuss personally
Model
GW4-1260
GW4-126
GW4-126
GW4-40.5
Basic info
Brand ROCKWILL
Model NO. GW4 Series HV disconnector
Rated voltage 252kV
Rated normal current 3150A
Rated peak value withstand current 125kA
Rated short-time withstand current 50kA
Series GW4 Series
Product Detail

Overview

Reliable Performance: Designed with robust linkages and corrosion-resistant materials to ensure consistent performance in harsh outdoor environments and minimal maintenance over a long service life.

Easy Integration: Available with manual or motorized operating mechanisms and adaptable mounting configurations to suit a range of substation layouts and system requirements.

Certified Quality: Disconnects are designed, manufactured, tested and delivered our in accordance with all applicable local and global standards (ANSI, IEEE) maintaining quality assurance.

 

Operating condition

1.working temperature:-40℃~40℃

2.Relative humidity: ≤90% (25℃) 

3.No corrosive gas, no obvious dirt, etc.

4.Altitude: <2000m

5.Pollution Level: III (25mm/kV), IV (31mm/kV)

6.Thickness of Ice: ≤10mm

 

Applications:

The three-phase AC 60Hz high-voltage disconnects designed for outdoor applications, providing reliable isolation of electrical equipment from energized circuits under no-load conditions. Engineered for use in power systems with rated voltages from 40.5kV to 252kV, this disconnect ensures safe maintenance operations and clear visual disconnection in substations and other high-voltage environments.

 

If you need to know about more parameters , Please check the model selection manual.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What are the methods for handling single-phase grounding faults in the small-current grounding system of the distribution network?
What are the methods for handling single-phase grounding faults in the small-current grounding system of the distribution network?
Current Status of Single-Phase Grounding Fault DetectionThe low accuracy of single-phase grounding fault diagnosis in non-effectively grounded systems is attributed to several factors: the variable structure of distribution networks (such as looped and open-loop configurations), diverse system grounding modes (including ungrounded, arc-suppression coil grounded, and low-resistance grounded systems), the increasing annual ratio of cable-based or hybrid overhead-cable wiring, and complex fault typ
Leon
08/01/2025
Neutral line current is actually greater than live line current? Why?
Neutral line current is actually greater than live line current? Why?
In a three-phase four-wire power distribution system, it is a consensus among industry insiders that the neutral line current should be very small when the three-phase loads are balanced. However, more and more phenomena are subverting this concept.For example, the advertising light boxes around a building use fluorescent lighting with electronic ballasts. The loads on the three-phase lines are balanced, with each phase current being approximately 90A, but the neutral line current reaches 160A.I
RW Energy
08/01/2025
Difference Between EMF and Voltage
Difference Between EMF and Voltage
One of the key differences between electromotive force (EMF) and voltage is that EMF refers to the energy supplied to charges, while voltage represents the energy required to move a unit charge from one point to another. Other distinctions between the two are detailed in the comparison chart below.Comparison ChartDefinition of VoltageVoltage is defined as the energy required to move a unit charge from one point to another. It is measured in volts (V) and denoted by the symbolV. Voltage is induce
Dyson
08/01/2025
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Case Analysis: Economy and Reliability of 110kV All-Aluminum Winding Power Transformers
Currently, the market price of copper remains high, fluctuating in the range of 70,000 to 80,000 yuan per ton. In contrast, the price of aluminum stays low, lingering in the range of 18,000 to 20,000 yuan per ton. For power transformers, replacing copper windings with aluminum windings in design will undoubtedly significantly reduce the material cost of products, bringing substantial cost savings to end customers.For a long time, it has been widely believed in the industry that aluminum windings
Ron
08/01/2025
What should be done if the neutral line current is too large?
What should be done if the neutral line current is too large?
As we all know, if an electrical line exceeds its rated load, it will overheat severely, and may even cause a fire. For safety reasons, overcurrent protection devices are therefore installed on lines. Whenever the current in the line exceeds the rated value, the overcurrent protection device will automatically cut off the line to prevent fire. The "excessive neutral line current" mentioned here refers to the phenomenon where the neutral line current is excessively high (more than 1.5 times the p
RW Energy
08/01/2025
What does the lifting inspection of a transformer core include?
What does the lifting inspection of a transformer core include?
1.Environmental Requirements for Transformer Core-Lifting Inspection1.1 General Environmental ConditionsCore - lifting operations are preferably carried out indoors. For large transformers that have to be operated outdoors due to specific conditions, sufficient measures must be taken to prevent moisture and dust contamination.Core - lifting should not be conducted during rainy or snowy weather or when the relative humidity exceeds 75%.The ambient air temperature during core - lifting should not
Rockwell
08/01/2025
×
Inquiry
Download