• DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS6B-550D/4000-63
DS6B-420D/4000-63
DS5A-252/5000-63
DS6B-252D/4000-63
DS6B-252D/3150-50
DS6B-252D/2000-40
DS6B-145D/3150-50
DS6B-145D/2000-40
DS6B-126D/3150-50
DS6B-126D/2000-50
Basic info
Brand ROCKWILL
Model NO. DS6B 126kV 145kV 252kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 4000A
Rated frequency 50/60Hz
Rated peak value withstand current 160kA
Rated short-time withstand current 63kA
Series DS6B
Product Detail

Product introduction:

DSDS6B Switch Disconnector is a kind of outdoor HV electricity transmission equipment’s at three-phase AC frequency of 50Hz/60Hz. It is used for breaking or connecting HV lines under no loads so that these lines can be changed and connected and the way the electricity runs is changed, In addition, it can be used to exercise safe electrical insulation for such HV electric

apparatuses as bus and breaker. The switch can open and close inductance/capacitance current and is able to open and close the bus to switch current.

This product is of the single-post bi-arm vertical telescope type (scissor-type) and suitable for the bus's Switch Disconnector. It can be laid out directly under the bus, thus occupying a small area. It’s effect of saving energy can be prominent at the substation where double bus lines are accompanied by the bypass bus.

The Switch Disconnector is accompanied by a JW10 earthing switch which will be used for the bus grounding at the lower layer, The grounding of the bus line at the upper layer requires the use of an independent earthing switch. 363kV and 550Kv Switch Disconnector and earthing switch are equipped with the SRCJ8 motor actuator for the single pole operation. Meanwhile, the tri-pole linkage can be achieved. The 126kV and 252kV Switch Disconnector adopt SRCJ3 motor-based actuator to realize the tri-pole linkage. The earthing switch adopts SRCS manual actuator to actualize tri-pole linkage.

This Switch Disconnector has passed the verification by the review procedure organized by China Machinery industry federation that the product structure and performance satisfy the requirements on perfection, and product's performance indices have reached the internally level of the same kinds of products

DS6B Switch Disconnector comprises three single poles and actuator. Each single pole is made of a base, post insulator, operating insulator and conducive part., The conductive pat includes the gear box and foldable conductive am fixed on the top of the post insulator, and the fixed contact hanging on the overload bus.

The actuator dives the operating insulator, and through the four link lever-driven scissor-type conductive arm, lift and lower the insulator to tighten or separate the moving contact and fixed contact on the directly overhead bus line, to open or close the Switch Disconnector. After the closing, a vertical insulating break will be formed.

Main characteristic:

  • Superior conductance system; With open structure, conductor is laid out in the middle of the transmission base while the main rod and reverse connecting rod are installed outside. Balancing spring is sealed with aluminum cover and transmission parts needing debugging are exposed for easy installation and debugging. dust prevention. Add a dustcover to bearing and adopt seal structure externally.
  • Contact forceps can cover a large area of rated contact, This product is in the double arm telescopic (scissor-type) structure. The forceps of the moving contact cover a large area of rated contact, particularly applicable to soft bus line, and also to hard bus line.
  • Open gear box, which has a good visibility, is convenient for installation, debugging and maintenance. The main crank arm is combined with operating flange to reduce he transmission link and the height of transmission base, which can improve the transmission efficiency and reliability. The rotation shat is designed as double bearing structure so that the transmission is flexible and reliable.
  • Structural design: the separation of machines from power. The design concept is the separation of machines from power, that is, the conductive elements, springs and mechanic driving elements are mutually isolated to prevent current from passing through springs and mechanical driving elements. in this way, the stability of the driving elements can be enhanced.
  • Provide one key sequential control "double confirmation" function expansion.

Main technical parameters:

Order notice 

Product model, rated voltage, rated current, rated short-lime withstand current and creepage distance must be specified at the goods-ordering time;

It must be decided whether a earthing switch should be attached to the Switch Disconnector;it must be decided whether the upper bus line of the Switch Disconnector is soft or hard.

Additionally, the external diameter of the tubular busbar shall be specified;

It must be decided whether the Switch Disconnector is arranged in cross-over or parallel form;

The actuator's model and name, motor's voltage, control voltage and the number of contacts for auxiliary switch

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Transformer operation and maintenance
Transformer operation and maintenance
Transformer Operating TemperatureDuring operation, transformers generate copper losses and iron losses, both of which are converted into heat, causing the transformer’s temperature to rise. Most transformers in China use Class A insulation. Due to heat transfer characteristics, significant temperature differences exist between different components during operation: winding temperature is the highest, followed by the core, and then the temperature of the insulating oil (with upper-layer oil being
Encyclopedia
07/31/2025
What Is An Inverter-integrated Transformer?
What Is An Inverter-integrated Transformer?
An inverter-integrated transformer is a power conversion device that combines the functions of an inverter and a transformer into a single unit. Widely utilized in renewable energy systems such as solar photovoltaic (PV) and wind power generation, its primary role is to convert direct current (DC) to alternating current (AC) while adjusting voltage levels (stepping up or down) via the transformer, ensuring compatibility with grid requirements or specific load demands.1. Basic Functions and Opera
Vziman
07/31/2025
Estimation of capacitive current
Estimation of capacitive current
The capacitive current is mainly determined by the length of the feeder, the cross-sectional area of the conductor, the dielectric constant, the height above the ground, and the rated voltage. The specific estimation methods are as follows:Estimation of capacitive current of overhead lines: For overhead lines of 3 - 35 kV, the capacitance per phase to ground is usually 5000 - 6000 pF/km. Based on this, the value of the single-phase grounding capacitive current per kilometer for lines of differen
Leon
07/31/2025
What are the technical characteristics of hydrogen-cooled power transformer technology?
What are the technical characteristics of hydrogen-cooled power transformer technology?
Power transformers are pivotal components in electrical grids, tasked with voltage conversion to enable efficient electricity transmission and distribution. As global energy demands surge and grid architectures grow increasingly complex, there is an urgent need for advanced transformer technologies that enhance efficiency, minimize environmental impact, and ensure operational reliability. Among emerging innovations, hydrogen-cooled power transformer technology has emerged as a particularly promi
Edwiin
07/31/2025
What are the basic knowledge points about transformer bushings?
What are the basic knowledge points about transformer bushings?
1. Functions of Transformer BushingsThe core function of transformer bushings is to lead the coil leads out to the external environment. They serve both as insulating components between the leads and the oil tank and as fixing devices for the leads.During the operation of a transformer, bushings continuously carry load currents and, in the event of an external short circuit, withstand short-circuit currents. Therefore, transformer bushings must meet the following requirements:Possess specified e
Rockwell
07/31/2025
What are the application scenarios of power transformers with a rating above 10kV?
What are the application scenarios of power transformers with a rating above 10kV?
High - voltage power transformers (above 10 kV) are extensively applied in various sectors, spanning residential and industrial fields. The following is a detailed overview of their main application scenarios and technical characteristics:1. Urban and Civil Applications1.1 Residential Communities and Commercial CentersThe 10 kV - rated combination transformer, favored for its compact size and fully sealed structure, is widely used in new residential complexes, shopping centers, and high - rise b
Vziman
07/31/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!