GPS8-05 Voltage / Current Protector

  • GPS8-05 Voltage / Current Protector
  • GPS8-05 Voltage / Current Protector
  • GPS8-05 Voltage / Current Protector

Key attributes

Brand Switchgear parts
Model NO. GPS8-05 Voltage / Current Protector
Rated voltage AC220V
Rated normal current 32A
Rated frequency 45Hz-65Hz
Series GPS8-05

Product descriptions from the supplier

Description

GPS8-05 is an intelligent device that combines power parameter monitoring and protection functions. Real time voltage, current, and energy data are displayed on digital screens, and multiple threshold protections such as overvoltage, undervoltage, and overcurrent are supported to provide safety assurance for household and small commercial electrical equipment. Its dual manifold structure enhances wiring stability and complies with modern electrical installation standards

GPS8-05 Digital Voltage/Current Protector Product Features:
1. Dual display monitoring system
The high-definition digital screen synchronously displays real-time voltage and current values, with an accuracy controlled within ≤1%, assisting users in accurately grasping the power supply status.
The independent LED indicator provides intuitive feedback on the operating status (normal/overvoltage/undervoltage/overcurrent), making it easy to quickly locate faults.
2. Custom protection mechanism
Support users to set overvoltage, undervoltage, and overcurrent protection thresholds as needed, flexibly responding to power grid fluctuations or equipment abnormalities.
3. Electric energy management function
Integrated energy metering module that can display real-time active power and cumulative electricity consumption, assisting in energy efficiency analysis and cost control.
4. Strengthen structural design
The dual current drainage architecture improves conductivity stability and wiring capacity, reduces the risk of poor contact, and extends service life.
5. Convenient integration solution
Compatible with 35mm standard electrical rails, plug and play, simplifying the installation and maintenance process of distribution boxes.

GPS8-05

 

Function

Over voltage, under voltage and over current

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65Hz

Operation voltage range

80V~400V(L-N)

Rated operational current

32A,40A,50A,63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Over current operation value

1~32A,40A,50A,63A,80A

Over current action delay

2s~600s

Power-up  delay

2s~600s

Reset time

2s~900s

Measurement error

≤1%

Electrical life(AC1)

1x104

Mechanical life

1x10⁶

Operating temperature

-20℃~+60℃

Storage temperature

-35℃~+75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

IP40 for front panel/IP20 terminals

Operating position

any

Overvoltage cathegory

III

Pollution degree

2

Dimensions

82×36×68mm

Weight

135g

Documentation Resource Library
Restricted
GPS8-05 Voltage / Current Protector
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the core functions and advantages of the GPS8-05 Protector?
A:

The core functions focus on safety protection, intelligence and convenience, with advantages in three key dimensions:

· Four-in-one comprehensive protection: Integrates overvoltage, undervoltage, overcurrent and leakage protection, accurately identifies circuit abnormalities, quickly cuts off faults, and avoids equipment burnout and electric shock risks.

·  High-precision intelligent monitoring: Equipped with a professional metering chip, it real-time detects voltage, current, power factor and cumulative power consumption with a measurement error ≤1%, facilitating energy management.

·  Flexible parameter configuration: Supports custom setting of overvoltage (230V-300V), undervoltage (140V-210V), overcurrent (1A-80A) thresholds and action delay time, adapting to different scenario requirements.

·  Humanized design: A large-size clear display intuitively shows parameters, supporting standard DIN rail installation and optional automatic/manual reset dual modes for convenient and efficient operation.

Q: What is the GPS8-05 Voltage/Current Protector?
A:

The GPS8-05 Voltage/Current Protector is a high-performance electrical safety device integrating four-in-one protection (overvoltage, undervoltage, overcurrent, leakage) and intelligent monitoring, specially designed for residential power distribution, small commercial buildings and industrial control scenarios. Compatible with AC 220V rated voltage and 50-60Hz frequency, it covers a working voltage range of 80V-400V, and can real-time monitor core parameters such as voltage, current, power and power consumption. When a circuit abnormality occurs, it quickly cuts off the fault loop within 0.1-10 seconds, and supports automatic or manual reset after the fault is eliminated without continuous manual monitoring, fully protecting electrical equipment and personal electrical safety.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • A Brief Discussion on the Selection of Grounding Transformers in Boost Stations
    A Brief Discussion on the Selection of Grounding Transformers in Boost StationsThe grounding transformer, commonly referred to as "grounding transformer," operates under the condition of being no-load during normal grid operation and overloaded during short-circuit faults. According to the difference in filling medium, common types can be divided into oil-immersed and dry-type; according to phase number, they can be classified into three-phase and single-phase grounding transformers. The groundi
    01/27/2026
  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.