• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


110kV Porcelain housed Surge Arrester

  • 110kV Porcelain housed Surge Arrester

Key attributes

Brand Wone
Model NO. 110kV Porcelain housed Surge Arrester
Rated voltage 300kV
Continuous operating voltage 228kV
Lightning impulse residual voltage 727kV
Series Surge Arrester

Product descriptions from the supplier

Description

Product introduction:

  • Surge arrester is also called overvoltage protector. It is connected in parallel with the protected electrical equipment. It can limit various overvoltage on electrical equipment, such as lightning overvoltage, operating overvoltage, etc., so as to protect the high voltage electrical from the damage of overvoltage.

  • Metaloxide varistor is used as the core component of surge arrester. The conductive mechanism of MOV is based on the non-linear volt-ampere characteristics of Schottky barrier model. The arrester is based on the principle of the non-linear volt-ampere characteristic of metal oxide varistor, which makes the arrester hold high resistance under the normal operating voltage of power system, which is equivalent to an insulator, and will not interfere with the normal operation of power system. When the overvoltage of power system endangers the safe operation of the system, the varistor triggers instantaneously and presents a low resistance. Forming a channel to release overvoltage energy, and clamp system voltage within the allowable range of the system to ensure the safe operation of the power system.

  • The arrester is porcelain-housed surge arrester. It has the advantages of high current impulse withstand capacity, large protection capacity and strong pollution resistance.

Parameter:

企业微信截图_17341409149808.png

 What are the structural characteristics of the porcelain shell arrester?

Porcelain Housing

The porcelain housing is a critical external structural component, offering excellent insulation properties and mechanical strength. The porcelain material can withstand electric field intensities of up to 110kV, preventing flashovers between internal components and the external environment. Additionally, the porcelain housing can endure certain mechanical stresses, such as wind and vibrations, protecting the sensitive internal components. Typically cylindrical in shape with a smooth surface, the porcelain housing helps reduce the adhesion of dust and contaminants. During manufacturing, it undergoes rigorous quality inspections to ensure there are no cracks or defects that could compromise its insulating properties.

Internal Components

The core internal component is the zinc oxide varistor disc. Under normal operating voltage, the zinc oxide varistor disc exhibits a high-resistance state, allowing only minimal current to pass through. When overvoltage occurs, its resistance drops sharply, forming a low-resistance path that allows the overvoltage-induced current to pass smoothly. These discs are made primarily from zinc oxide using specialized manufacturing processes, resulting in nonlinear volt-ampere characteristics that effectively limit the amplitude of overvoltages. Additionally, the internal structure may include connecting elements to link the varistor discs appropriately and auxiliary components like grading rings to ensure uniform voltage distribution across the discs during high-voltage conditions.

Sealing and Connection Structure

The porcelain-housed surge arrester features a robust sealing structure to prevent moisture, dust, and harmful gases from entering and affecting the performance of internal components. At both ends, there are connection structures for integrating the arrester into 110kV power lines. These connection parts are typically made of metal, capable of withstanding high voltages and large currents while providing excellent conductivity. This ensures that during an overvoltage event, current can flow smoothly into and out of the arrester.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file

IEE Business will not sell or share your personal information.

Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.