Key attributes

Brand Wone
Model NO. Expulsion fuse cutout
Rated voltage 38kV
Rated normal current 100/200A
Rated interrupting current 8kA
Series Expulsion fuse

Product descriptions from the supplier

Description

Product features:

High performance of weather aging resistance:

  • For porelain insulator, the porcelain body connects with hardware fitting by cement pouring, we use the (por-rok)ANCHORING cement manufactured by CGM INC from USA. This kind of cement has rapid solidification, high mechanical strength, low expansion coefficient and superior weather resistance.

  • For polymer insulator, the hardware fitting crimped onto fiberglass rod, material of housing and sheds manufacture of high-temperature Vulcanized Silicone Rubber, and the insulator moulded by one piece injection molding. It has good sealing performance and good performance of tracking and erosion resistance.

  • All ferrous parts processed by hot dip galvanized, its zinc coating more than 86u, it has good corrosion resistance.


Design feature of single vent:

  • Our fuse cutout adopts the design feature of single vent, exhaust downwards and outwards when fuse cutout interrput. Prevent the intrusion of rainwater, avoid damage to the upper line by free gas, and this design can improve the interrput capacity.

  • It adopts Arc-shortening copper rod to improve the interrput capacity when short circuit fault.

Excellent conductivity:

  • All copper casting part adopts bronze/brass, it has excellent mechanical strength and excellent conductivity.

  • All contact parts be silver-plated, it adopts convex design on the contact surface, this design can reduce the contact resistance and ensure excellent conductivity.

  • The high-strength memory cooper alloy sheets can ensure contact with lower contact smoothly and without any affecting when fuse drop out.


Reliable load breaking capacity:

  • For Loadbreak type fuse cutout, its arc chamber made of special reinforced nylon material. It has good mechanical strength, anti-aging and flame retardant, suitable for use the area like high ultraviolet area, high altitude area, coastal area, etc.

Relevant international executive standards:

  • All fuse cutouts we manufacture and test according to the latest international standard IEC 60282-2:2008 & IEEE Std 037.41-2008 & IEEEStd 037.42-2009.

Product categories:

企业微信截图_173389368371.png

企业微信截图_17338939118484.png

Technical parameter:

企业微信截图_17338941496775.png

企业微信截图_1733894339996 (1).png

企业微信截图_17338945324685.png

企业微信截图_17338946944917.png

Warm tips:

When order.please indicate the detailed information as below listed:

  • Rated voltage and rated current .

  • Minimum creepage distance.

  • The material of insulator.

  • Please indicate whether arc-shortening rod should be fitted with fuse cutout.

  • Please indicate the type of mounting bracket.

How does a expulsion fuse  work?

Normal Operating State:

  • During normal operation, the expulsion fuse allows the normal operating current to pass through. The fusible element conducts current normally, behaving like a regular conductor, without hindering the operation of the power system.

Fault Operating State:

  • When an overload or short-circuit fault occurs in the circuit, causing the current to exceed the rated current of the fuse, the fusible element heats up and melts, generating an arc. The high temperature of the arc causes the gas-producing material inside the fuse to decompose, generating a large amount of high-pressure gas. These gases are expelled at high speed, stretching, cooling, and ultimately extinguishing the arc, thereby interrupting the fault current and protecting the lines and connected electrical equipment.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Surge Arrester Monitoring: Trends, Challenges & Future Outlook
    1. Current Status and Shortcomings of Online MonitorsCurrently, online monitors are the most commonly used tools for surge arrester monitoring. While they can detect potential defects, they have significant limitations: manual on - site data recording is required, precluding real - time monitoring; and post - collection data analysis adds to operational complexity. IoT - based intelligent monitoring overcomes these issues—collected data is uploaded via the IoT to processing platforms,
    07/31/2025
  • Surge Arrester Handover & Live Testing Technologies for Reliable Power Grid Operation
    1. Overview of Surge Arrester Handover Test Technology1.1 Necessity of Handover TestThe handover test is a crucial step in ensuring the performance and safe operation of surge arresters within power systems. For power systems with voltage levels at 220 kV and below, surge arresters play a core role in protecting electrical equipment from damage caused by overvoltages and lightning strikes. However, during the process from the arrester leaving the factory to its actual operation after installatio
    07/31/2025
  • Surge Arrester Failure Analysis and Prevention: Key Causes of 10 kV Distribution Arresters' Malfunctions
    1. IntroductionDuring power system operation, main equipment faces threats from internal and atmospheric overvoltages. Surge arresters, especially metal oxide arresters (MOAs) with excellent nonlinear volt - ampere characteristics, are key for protection due to their good performance, large current - carrying capacity, and strong pollution resistance. However, long - term exposure to power frequency voltages, along with component quality, manufacturing processes, and external environments, makes
    07/30/2025
  • Advanced Online Monitoring System for Zinc Oxide Surge Arresters: Key Technologies and Fault Diagnosis
    1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer. Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source. Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs). Process Layer: Features monitoring terminals for Potential Transformers (PTs) a
    07/30/2025
  • Enhancing Surge Arrester Online Monitors: Key Improvements for Precision, Fault Diagnosis, and Reliability
    1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Effic
    07/30/2025
  • Real-Time Monitoring of Surge Arresters in 10kV GIS Cubicles: Enhancing Railway Power System Safety
    1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo en
    07/30/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.