• DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
discuss personally
Model
DS17-800/5000-63
DS17A-550/4000-63
DS17B-550/3150-50
DS17B-420/3150-50
DS17A-363/5000-63
DS17A-363/3150-50
DS17B-252/5000-63
DS17B-252/3150-50
DS17B-126/3150-40
DS17B-126/2500-40
Basic info
Brand ROCKWILL
Model NO. DS17 126kV 252kV 363kV 420kV 800kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 3150A
Series DS17
Product Detail

Description:

DSDS17 series disconnector adopts double-column horizontal telescopic structure, mainly composed of base, insulator, conductive system, operating mechanism, etc. The disconnector is operated by CJ11 type motor operating mechanism for opening and closing. The attached ground switch is mainly composed of ground switch system and operating mechanism, and each group of ground switches is operated by a CJ11 motor operating mechanism for opening and closing.


Main Features:

  •  Strong product flow capacity, long mechanical life.

  • The transmission shaft of the product is made of high quality alloy steel, the outer surface is treated with hot dip galvanizing, and the anti-corrosion ability is strong; The shaft sleeve is made of high-strength engineering plastic, which has good wear resistance and strong anti-corrosion property.

  • The product adopts a fully sealed structure between the moving contact base and the contact finger, effectively avoiding the intrusion of rain, snow and frost, and has strong waterproof ability.

  • The contact surface of the product adopts advanced silver plating technology, and the hardness of the silver layer reaches 140HV, which enhances the electrical conductivity and wear resistance of the surface.

Technical parameter

 

image.png

image.png

What are the application scenarios of disconnectors?

In substations, isolator switches are essential equipment. They are used to isolate busbars of different voltage levels from lines, transformers, and other equipment. For example, in 110 kV or 220 kV substations, isolator switches are installed at the connection points of incoming lines, outgoing lines, and transformers, playing a crucial role during equipment maintenance and switching operations.

Industrial Enterprise Distribution Systems:

In the distribution systems of industrial enterprises, isolator switches are used to isolate power connections between different workshops and equipment groups. When a particular workshop or equipment group needs maintenance or inspection, the isolator switch can be used to isolate it from the power supply without affecting the normal operation of other workshops or equipment groups. Additionally, in internal power line switching operations within the enterprise, isolator switches can be used in conjunction with other switching devices.

Transmission Lines of Power Systems:

At switching stations and substations where transmission lines connect, isolator switches are installed to manage the connection, disconnection, and maintenance of the lines. For example, on high-voltage transmission line towers, isolator switches can be installed below the insulator strings to facilitate line maintenance and inspection. They can also be used to isolate the lines from the busbars of the substation when necessary.


 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)
Analysis of Partial Discharge Principle (1)Under the action of an electric field, in an insulation system, discharge occurs only in some regions and does not penetrate between the conductors with the applied voltage. This phenomenon is called partial discharge. If partial discharge occurs near a conductor surrounded by gas, it can also be called corona.Partial discharge can occur not only at the edge of a conductor but also on the surface or inside an insulator. The discharge occurring on the su
Leon
07/19/2025
What types of FACTS controllers are there?
What types of FACTS controllers are there?
According to the type of connection FACTS Controller with the power system, it is classified as;Series Connected ControllerShunt Connected ControllerCombined Series-Series ControllerCombined Shunt-Series ControllerSeries-Connected ControllersSeries controllers introduce a voltage in series with the line voltage, typically using capacitive or inductive impedance devices. Their primary function is to supply or absorb variable reactive power as needed.When a transmission line is heavily loaded, the
Edwiin
07/19/2025
What are FACTS and related technologies?
What are FACTS and related technologies?
FACTS (Flexible Alternating Current Transmission System) refers to a power electronics-based system that uses static devices to enhance the power transfer capability and controllability of AC transmission networks.These power electronic devices are integrated into conventional AC grids to boost key performance metrics, including:Power transfer capacity of transmission linesVoltage stability and transient stabilityVoltage regulation precisionSystem reliabilityThermal limits of transmission infras
Edwiin
07/19/2025
What are the differences between HVAC and HVDC?
What are the differences between HVAC and HVDC?
Difference Between HVAC and HVDCElectricity generated in power plants is transmitted over long distances to electrical substations, which then distribute it to consumers. The voltage used for long-distance power transmission is extremely high, and we will explore the reasons for this high voltage later. Additionally, the transmitted power can be in either alternating current (AC) or direct current (DC) form. Therefore, power can be transmitted using either HVAC (High Voltage Alternating Current)
Edwiin
07/19/2025
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?
What are the Advantages of HVDC over HVAC?Electricity travels long distances before reaching consumers. Power plants, often remote, supply electricity through hundreds of miles and multiple substations. High-voltage transmission reduces line losses, with both AC and DC used. Though AC is familiar via utility poles and home outlets, HVDC offers unique advantages in power transmission.The goal of power transmission is to minimize losses and costs. While both face influencing factors, HVDC has more
Edwiin
07/19/2025
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Is the neutral - point grounding method of the power grid of 110kV and above only the neutral - point direct grounding method?
Neutral - Point Grounding Modes and Protection of Transformers in Power GridsFor systems ranging from 110 kV to 500 kV, an effective grounding method shall be adopted. Specifically, under all operating conditions, the ratio of zero - sequence reactance to positive - sequence reactance X0/X1 of the system should be a positive value and not exceed 3. Meanwhile, the ratio of zero - sequence resistance to positive - sequence reactance R0/X1should also be a positive value and not exceed 1.In 330 kV a
Leon
07/19/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!