Key attributes

Brand ROCKWILL
Model NO. Compact and Prefabricated Substation
Rated voltage 35kV
Rated normal current 5000A
Series Compact Substation

Product descriptions from the supplier

Description

Product overview

Compact substations, mini substations, and prefabricated substations are innovative alternatives to traditional indoor substations. These advanced units are engineered to fulfill diverse user requirements, including electric energy measurement, reactive power compensation, and customized high and low voltage configurations. They embody the future of small and medium-sized power distribution infrastructure.

Technical Specifications 

  • Electrical Parameters: Rated for AC frequencies of 50Hz/60HZ, with a maximum operating voltage of 35KV and a maximum operating current of 5000A. 

  • Wide Application: Ideal for industrial and mining enterprises, ports, public facilities, high-rise buildings, and residential communities. Our products have a strong global footprint, predominantly exported to Asia, Africa, and other regions. We also offer comprehensive OEM/ODM services to meet unique client needs.

  •  Standards Compliance: Adheres to international and national standards such as IEC60067 and GB 17467-2010, ensuring quality and reliability.

Product Advantages 

  • Cutting-edge Technology: Boasting a fully enclosed and insulated structure, these substations ensure safe and reliable operation. They are user-friendly, virtually maintenance-free, and offer cost-effective solutions with low equipment investment. 

  • Robust Shell Design: The casing features excellent durability, thermal insulation, and ventilation. It demonstrates stable performance in various environments, with corrosion resistance, dustproof, and waterproof properties, while maintaining an aesthetically pleasing appearance. Multiple shell materials are available, including steel plates, composite plates, stainless steel plates, and cement plates, with protection grades up to IP67. 

Functional Configuration 

Independent Compartments: 

  • Divided into three separate areas: high voltage room, low voltage room, and transformer room. 

  • High Voltage Room: Equipped with XGN15, HXGN17, or SF6 switchgear, ensuring efficient high-voltage management. Low Voltage Side: Utilizes panel or cabinet-mounted structures, enabling the creation of customized power supply schemes. It supports functions like power distribution, lighting control, reactive power compensation, and energy metering. The main switch can be a universal circuit breaker or an intelligent circuit breaker, providing flexible installation and easy operation. 

  • Transformer Options: Available with fully sealed oil-immersed transformers or dry type transformers to suit different application needs. 

  • Superior Busbar System: Supports three-phase four-wire or three-phase five-wire systems. Constructed from high-quality three-phase tinned copper busbars, it offers high mechanical strength and excellent heat dissipation capabilities.

Operating Conditions 

  • Temperature: Ambient air temperature ranges from -45 °C to 45 °C. 

  • Altitude: Suitable for altitudes up to 1000m; can be extended to 4000m with customized transformers and low-voltage components. 

  • Installation: Recommended for installation with a vertical inclination not exceeding 5°, in environments free from severe vibrations and impacts. 

  • Humidity: Operational in air humidity levels of up to 90% at +25℃.

  •  Environmental Requirements: Designed for use in areas without conductive dust, explosion hazards, or gases that could corrode metal and electrical components. Outdoor installations should be in locations where wind speeds do not exceed 35m/s. For conditions outside these norms, we offer custom solutions tailored to your specific requirements.

Ordering Guidelines 

When placing an order, please provide the following details:

 Main loop scheme diagram and secondary loop system diagram. Electrical schematic diagram of the auxiliary circuit and wiring terminal layout. Equipment layout drawing, combination drawing, and floor plan drawing. Model, specification, and quantity of main electrical components. Incoming and outgoing line methods and cable specifications. Preferred equipment shell material and color. Any other special requirements can be discussed and accommodated through direct negotiation with our manufacturing team. 

We warmly invite customers to visit our factory. With our OEM/ODM services, we can also customize the protection level according to your specific project demands.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Intelligent Substation Maintenance Pressure Plate Operation Guide
    According to the "Eighteen Major Anti-Accident Measures for Power Grid of State Grid Corporation of China (Revised Edition)" promulgated in 2018, operation and maintenance units should improve the on-site operation regulations for intelligent substations, refine the usage instructions and abnormal handling methods for various messages, signals, hard pressure plates, and soft pressure plates of intelligent equipment, standardize the operation sequence of pressure plates, strictly follow the seque
    12/15/2025
  • What Is a Substation Bay? Types & Functions
    A substation bay refers to a complete and independently operable assembly of electrical equipment within a substation. It can be regarded as a fundamental unit of the substation’s electrical system, typically comprising circuit breakers, disconnectors (isolators), earthing switches, instrumentation, protective relays, and other associated devices.The primary function of a substation bay is to receive electrical power from the power system into the substation and then deliver it to the required d
    11/20/2025
  • What is the difference between a pad-mounted substation and a traction substation?
    Pad-Mounted Substation (Box-Type Substation)Definition:A pad-mounted substation, also known as a prefabricated substation or pre-assembled substation, is a compact, factory-assembled power distribution unit that integrates high-voltage switchgear, a distribution transformer, and low-voltage distribution equipment according to a specific wiring scheme. It combines functions such as voltage step-down and low-voltage power distribution into a single unit housed in a fully enclosed, movable steel en
    11/20/2025
  • What Are the Differences Between Substations, Switching Stations, and Distribution Rooms?
    What Are the Differences Between Substations, Switching Stations, and Distribution Rooms?A substation is a power facility in the electric power system that transforms voltage levels, receives and distributes electrical energy, controls the direction of power flow, and adjusts voltage. It interconnects power grids of various voltage levels through its transformers. In specific applications—such as submarine power cables or long-distance transmission—some systems use high-voltage direct current (H
    11/20/2025
  • Application of Maintenance-Free Transformer Breathers in Substations
    Currently, traditional-type breathers are widely used in transformers. The moisture-absorbing capability of silica gel is still judged by operation and maintenance personnel through visual observation of the color change of silica gel beads. Subjective judgment by personnel plays a decisive role. Although it has been clearly stipulated that silica gel in transformer breathers should be replaced when more than two-thirds of it changes color, there is still no accurate quantitative method to deter
    11/18/2025
  • Application of UAV Technology in Sequential Control Operations of Substations
    With the advancement of smart grid technologies, sequential control (SCADA-based automated switching) in substations has become a core technique for ensuring stable power system operation. Although existing sequential control technologies have been widely deployed, challenges related to system stability under complex operating conditions and equipment interoperability remain significant. Unmanned Aerial Vehicle (UAV) technology—characterized by its agility, mobility, and non-contact inspection c
    11/18/2025

Related Solutions

  • Rockwill Photovoltaic Prefabricated Substation Brazil Market Project Solution
    1.Why Choose Rockwill?1.1 Technological Leadership, Tailored for Brazil’s Complex Needs Hiqgh-Reliability Design: Adapted to Brazil’s diverse terrain (e.g., Amazon rainforests, plateaus) and extreme weather (high temperatures, heavy rainfall) with containerized structure and IP65 protection grade. Utilizes gas-filled cabinet technology to ensure stable operation in humid and dusty environments. Smart O&M: Integrated remote monitoring system for real-time tracking of
    05/04/2025
  • Rockwill Electric & Overseas Contractors: Full Lifecycle Partnership Solutions for Prefabricated Substations
    1.Localized Collaboration: Rooted in Regional Needs, Co-Creating Value with You1.1 Climate-Adaptive Co-DesignTailored solutions for extreme environments: Dustproof & High-Temperature Substations: IP54-rated enclosures with intelligent temperature control systems, ideal for African sandstorm-prone areas. Modular Flood-Resistant Structures: Rapid disassembly/reassembly for Southeast Asian projects, boosting post-disaster recovery efficiency by 60%.1.2 Standards & Certification Collaboratio
    05/04/2025
  • VZIMAN Prefabricated Substation Solutions for African Manufacturing Plants
    1. Core Challenges in African Manufacturing Plants1 Unstable Power SupplyAging grids and insufficient generation capacity plague African nations. For instance, South Africa's 2023 power deficit caused 5%-10% GDP loss, while 97% of Nigerian factories rely on expensive diesel generators (annual fuel costs: $14 billion). Frequent outages disrupt production continuity and damage equipment.1.2Weak InfrastructureRemote areas lack transmission networks, and traditional substations require 3–6
    05/07/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.