735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation

  • 735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation

Key attributes

Brand ROCKWILL
Model NO. 735kV 750kV 765kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation
Rated voltage 750kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series ODFPS

Product descriptions from the supplier

Description

Product Description:

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

The 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation is a critical component designed for the highest tiers of power transmission systems. Its robust oil-immersed cooling technology ensures stable thermal performance and long-term reliability under heavy loads. The unique three-winding configuration provides exceptional operational flexibility, enabling efficient power transfer and system interconnection. As a "no excitation" design, it offers superior reliability and simplified maintenance by eliminating the need for on-load tap-changing mechanisms, making it an ideal and dependable solution for ultra-high voltage (UHV) grid applications that demand unwavering performance.

This power transformer is fully compliant with international standards including IEC 60076-1, IEEE C57.12.00, ANSI C57.12.90, AS/NZS 60076.5 and EN 61558-1. It meets quality requirements and is widely adaptable to the operational needs of power grids in multiple overseas regions.

Product Characteristics:

  • Optimized Structural Design: Utilizes advanced computational analysis of electrical, magnetic, mechanical, and thermal behavior to ensure robust and reliable construction.

  • Superior Electrical Performance: Complies with IEC standards while offering customized solutions, with partial discharge levels significantly lower than IEC 60076-3 limits.

  • Enhanced Operational Reliability: Multi-physics field analysis optimizes insulation, amp-turns balance, and cooling, delivering strong resilience to overvoltage and short-circuit events while eliminating risks of local overheating.

  • Premium Component Selection: Provides an exceptional user experience with a clean appearance, leak-free construction, and maintenance-free operation—no core disassembly required.

Technical Parameters

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Among these, some autotransformers cover non-standard voltage levels including 121kV, 132kV, 138kV, 200kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV and 756kV,  We also provide customization services.

Rated capacity (kVA)

334

500

500

700

Voltage combination and tapping range

HV (kV)

765/√3

Tapping range(kV)

230/√3±2×2.5%

345/√3±2×2.5%

LV (kV)

63

Vector group

La0I0

No-load loss(kW)

95

110

125

130

On-load loss(kW)

570

860

860

1225

No-load current (%)

0.15

0.15

0.15

0.15

Short-circuit impedance (%)

HV-MV14

HV-LV50

MV-LV33

HV ~MV 

19 ~ 22

HV-LV46

MV-LV

23~24

HV-MV14

HV-LV50

MV-LV33

HV-MV18

HV-LV58

MV-LV36

Capacity assignment (MVA)

334/334/100

500/500/150

500/500/150

700/700/233

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

Normal Service Conditions

(1) Altitude:  ≤1000m;

(2) Ambient temperature:Maximum temperature: +40℃;Maximum monthly average temperature: +30℃;Maximum yearly average temperature: +20℃;Minimum temperature: -25℃.

(3) Power supply: approximate sinusoidal wave, three-phase symmetrical approximately

(4) Installation site: indoor or outdoor, without the obvious contamination.Note: The transformer used in special conditions should be specified when ordered.

Introduction to Structure and Performance:

Core:

  • Adopting highest quality, non-aging, cold-rolled, grain-oriented, and high permeability silicon steel lamination silicon steel sheets.

  • Processed on the GEORG length-cutting line from Germany.

  • Fully mitred joint, step lapping and polyester tape binding structure making the transformer with low no-load losses and low noise level.

  • Placing vibration isolation pads between the body and the tank to reduce vibration that transmits to the tank.

Winding:

  • Winded by high-quality oxygen free copper with lower resistivity.

  • Processed and manufactured on horizontal winding machines and large CNC vertical winding machines from both radial and axial directions.

  • Reasonable transposition applied between paralleling wires, magnetic shielding used for guiding flux leakage when necessary to reduce the stray losses of the transformer.

  • Reasonable design of insulation structure improving the ability of withstanding overvoltage.

  • Optimizing the ampere turns distribution of the winding, increasing the radial support and axial compression of the winding, using the pre-densification of spacers, constant pressure drying, to resist the impulse current.

Tank:

  • Bell type or cover bolted type tank.

  • Carbon dioxide shielded welding process.

  • High-quality gaskets and the limit groove.

  • Strict leak detection test procedures.

Others:

  • Cold-weld connection technology leads to improve the cleanliness of active part.

  • The vacuum disassembly and the vacuum filling technology measures reduce the partial discharge level effectively and enhance the transformer operating reliability.

  • The structure of "Six Direction Positioning" between the active part and the tank assures that the transformer has a strong ability of anti-transportation impact or anti-earthquake.

  • Surface treatment and coating, fine processing to tank surface, 7 steps such as acid-washing and phosphating, etc. special anti-fouling paint, ensuring not falling off or rusting away.

 

FAQ for
Q: How does the oil-immersed design of the 750kV Single-phase Autotransformer with Three Windings benefit its operation?
A:

The oil-immersed design uses insulating oil for two key functions: first, it provides excellent electrical insulation between windings and components; second, it acts as a cooling medium, dissipating heat generated during operation to ensure the transformer works within a safe temperature range, thus extending its service life.

Q: What is the significance of "no excitation" in the 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation?
A:

"No excitation" means the transformer can only adjust voltage when it is completely disconnected from the power grid (no load current). This design simplifies the structure, enhances reliability, and is suitable for scenarios where voltage regulation frequency is low and stable grid operation is prioritized.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • How Often Should Transformers Be Overhauled?
    1. Transformer Major Overhaul Cycle The main transformer shall undergo a core-lifting inspection before being put into service, and thereafter a core-lifting overhaul shall be performed every 5 to 10 years. Core-lifting overhaul shall also be carried out if a fault occurs during operation or if issues are identified during preventive tests. Distribution transformers operating continuously under normal load conditions may be overhauled once every 10 years. For on-load tap-changing transformers, t
    12/09/2025
  • Adjustment and Precautions for H61 Oil Power 26kV Electric Transformer Tap Changers
    Preparatory Work Before Adjusting the Tap Changer of H61 Oil Power 26kV Electric Transformer Apply for and issue a work permit; carefully fill out the operation ticket; conduct a simulation board operation test to ensure the operation is error-free; confirm the personnel who will carry out and supervise the operation; if load reduction is required, notify affected users in advance. Before construction, power must be disconnected to take the transformer out of service, and voltage testing must be
    12/08/2025
  • H59/H61 Transformer Failure Analysis and Protection Measures
    1.Causes of Damage to Agricultural H59/H61 Oil-Immersed Distribution Transformers1.1 Insulation DamageRural power supply commonly uses a 380/220V mixed system. Due to the high proportion of single-phase loads, H59/H61 oil-immersed distribution transformers often operate under significant three-phase load imbalance. In many cases, the degree of three-phase load imbalance far exceeds the limits permitted by operational regulations, causing premature aging, deterioration, and eventual failure of th
    12/08/2025
  • What Is an H61 Distribution Transformer? Uses & Setup
    H61 distribution transformers refer to transformers used in power distribution systems. In a distribution system, high-voltage electricity must be converted into low-voltage electricity via transformers to supply electrical equipment in residential, commercial, and industrial facilities. The H61 distribution transformer is a type of infrastructure equipment primarily used in the following scenarios: Supplying power from high-voltage grids to low-voltage grids: During power delivery, high-voltage
    12/08/2025
  • How to Diagnose Faults in H59 Distribution Transformers by Listening to Their Sounds
    In recent years, the accident rate of H59 distribution transformers has shown an upward trend. This article analyzes the causes of failures in H59 distribution transformers and proposes a series of preventive measures to ensure their normal operation and provide effective assurance for power supply.H59 distribution transformers play a vital role in power systems. With the continuous expansion of power system scale and the increasing single-unit capacity of transformers, any transformer failure n
    12/08/2025
  • What lightning protection measures are used for H61 distribution transformers?
    What lightning protection measures are used for H61 distribution transformers?A surge arrester should be installed on the high-voltage side of the H61 distribution transformer. According to SDJ7–79 "Technical Code for Design of Overvoltage Protection of Electric Power Equipment," the high-voltage side of an H61 distribution transformer should generally be protected by a surge arrester. The grounding conductor of the arrester, the neutral point on the low-voltage side of the transformer, and the
    12/08/2025

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.