• 66kV Three Phase Oil-Immersed Earthing Transformer
66kV Three Phase Oil-Immersed Earthing Transformer
discuss personally
Model
JDS-350KVA-66KV
Basic info
Brand ROCKWILL
Model NO. 66kV Three Phase Oil-Immersed Earthing Transformer
Rated voltage 66KV
Phases Three-phase
Series JDS
Product Detail

Product Overview
Rockwill delivers reliable and high-performance earthing transformers designed for 66kV power systems. Our oil-immersed transformers are engineered to provide stable neutral grounding solutions while ensuring operational safety and system protection. Manufactured in compliance with international standards including IEC and GB, these transformers incorporate premium materials and rigorous quality control throughout production.

Basic Info.

Key Features

  • Voltage Class: 66kV system voltage (200 BIL)

  • Capacity Range: Standard units from 100kVA to 10,000kVA

  • Winding Configuration: Optimized zigzag (ZNyn) design

  • Cooling System: ONAN/OFAF cooling options

  • Insulation: Mineral oil or synthetic ester fluid

  • Construction:

    • Corrugated tank or radiator cooling

    • Hermetically sealed or conservator tank options

    • CRGO silicon steel core

    • Copper/aluminum windings

Technical Advantages

  • Enhanced Safety: Built-in Buchholz relay and pressure relief device

  • Low Impedance: Zero-sequence impedance <15&Omega; for effective fault current management

  • Durability: Corrosion-resistant paint system for outdoor installations

  • Efficiency: Reduced no-load losses through optimized core design

  • Flexibility: Off-circuit tap changer (&plusmn;5% in 2.5% steps)

Typical Applications

Utility Networks:

  • Neutral grounding for 66kV transmission systems

  • Arc suppression coil connections

  • Resistance grounding systems

 Industrial Plants:

  • Petrochemical facilities

  • Mining operations

  • Steel manufacturing plants

Renewable Energy:

  • Wind farm collector stations

  • Solar PV substations

  • Hydroelectric plants

Performance Specifications

  • Temperature Range: -30&deg;C to +40&deg;C ambient

  • Humidity: &le;95% monthly average

  • Altitude: Up to 2000m ASL

  • Sound Level: &le;75dB at 1m

  • Efficiency: &ge;99.2% at full load

Testing Protocol
All units undergo comprehensive testing including:

  • Zero sequence impedance measurement

  • Induced overvoltage test (260Hz)

  • Lightning impulse test (350kV)

  • Temperature rise test (65K max.)

  • Oil dielectric strength test (&ge;50kV)

Service Conditions

  • Suitable for indoor/outdoor installation

  • Wind resistant up to 35m/s

  • Non-explosive environments

  • Seismic capability: 0.3g horizontal acceleration

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!