• 20kV Three Phase Oil-Immersed Earthing Transformer
20kV Three Phase Oil-Immersed Earthing Transformer
discuss personally
Model
JDS-100KVA-20KV
Basic info
Brand ROCKWILL
Model NO. 20kV Three Phase Oil-Immersed Earthing Transformer
Rated voltage 20kV
Rated capacity 100kVA
Phases Three-phase
Series JDS
Product Detail

Product Overview
Rockwill's JDS series oil-immersed earthing transformers provide reliable neutral grounding solutions for 20kV power systems. Designed with robust copper windings and advanced oil-cooling technology, these transformers ensure stable system operation while preventing damage from ground faults.

Basic Info

Key Specifications

  • Model: JDS-100/20

  • Capacity: 100kVA

  • Voltage: 20kV

  • Frequency: 50/60Hz

  • Winding: Copper two-winding design

  • Core: Ring-shaped silicon steel

  • Cooling: ONAN (Oil Natural Air Natural)

  • Impedance: Low zero-sequence impedance (<10&Omega;)

  • Certification: ISO 9001, CTQC tested

Technical Advantages

  1. Superior Grounding Performance

    • Specially designed winding configuration for optimal neutral point stability

    • Withstands 100A short-circuit current for 10 seconds

    • Low zero-sequence impedance ensures effective fault current diversion

  2. Advanced Oil-Cooled Design

    • Hermetically sealed corrugated tank prevents oil contamination

    • Mineral oil insulation with -30&deg;C to +40&deg;C operating range

    • Optional Midel 7131 ester fluid for enhanced fire safety

  3. Robust Construction

    • Heavy-gauge steel tank with anti-corrosion treatment

    • Precision-engineered core with reduced magnetic losses

    • Vibration-resistant mounting system

  4. Smart Protection Features

    • Standard Buchholz relay for internal fault detection

    • Pressure relief device for overload conditions

    • Oil level indicator with alarm contacts

Application Scenarios

  1. Industrial Power Systems

    • Ideal for manufacturing plants with sensitive equipment

    • Protects against ground faults in 20kV distribution networks

    • Suitable for harsh industrial environments

  2. Renewable Energy Installations

    • Wind farm collector substations

    • Solar park step-up stations

    • Biomass power generation facilities

  3. Infrastructure Projects

    • Metro power supply systems

    • Airport electrical networks

    • Hospital backup power systems

Why Choose Rockwill?

  • 20+ years of transformer manufacturing expertise

  • Custom engineering support available

  • Complete type test reports provided

  • Global service network with 24/7 technical support

  • Environmentally conscious production processes

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!