• 35kV Dry Type Grounding Transformer Cast Resin 3 Phase
35kV Dry Type Grounding Transformer Cast Resin 3 Phase
discuss personally
Model
DKSC-400KVA
Basic info
Brand ROCKWILL
Model NO. 35kV Dry Type Grounding Transformer Cast Resin 3 Phase
Rated capacity 400kVA
Phases Three phase
Series DKSC
Product Detail

Overview

Rockwill Zigzag (Z-Type) Grounding Transformers provide a reliable artificial neutral grounding solution for power systems where the neutral point is unavailable, such as delta-connected or ungrounded star systems. These specialized transformers create a stable neutral point for connecting arc suppression coils (Petersen coils) or neutral grounding resistors, ensuring safe and effective system grounding.

Additionally, Rockwill grounding transformers can be equipped with a secondary winding to supply auxiliary power, offering a cost-effective alternative to separate station transformers.

Key attributes

Key Applications

  • Substations and distribution networks (35kV and below)

  • Industrial power systems requiring a neutral grounding point

  • Renewable energy plants (wind/solar farms) with ungrounded sources

Main Technical Specifications

  • Rated Capacity: 100kVA to 5500kVA

  • Rated Voltage: Up to 35kV

  • Insulation Class: Class F (compliant with IEC 60076)

  • Connection Type: Zigzag (Z-Type) for optimal zero-sequence performance

  • Zero-Sequence Impedance: Low impedance (~10Ω) for efficient fault current handling

Key Features & Benefits

  • Advanced Zigzag Winding Design – Unlike conventional transformers, Rockwill’s Z-Type configuration ensures zero-sequence flux circulates within the core, minimizing impedance and enhancing grounding performance.

  •  Full-Capacity Arc Suppression Support – Compatible with 90-100% rated capacity arc suppression coils, far exceeding the 20% limit of standard transformers.

  • Dual-Purpose Functionality – Optional secondary winding allows the transformer to supply station power, reducing the need for additional equipment.

  •  Dry-Type, Cast Resin Construction – Maintenance-free, flame-resistant, and suitable for harsh environments.

  • High Efficiency & Reliability – Engineered for stable operation under fault conditions, preventing magnetic saturation.

  •  IEC 60076 Compliant – Manufactured to international standards for global reliability.

Why Choose Rockwill?

Rockwill grounding transformers deliver superior performance, safety, and cost savings by combining neutral grounding and auxiliary power supply in a single unit. Their optimized design ensures enhanced system protection, reduced downtime, and lower installation costs—making them the ideal choice for modern power systems.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
What is the difference between a dielectric and an insulator?
What is the difference between a dielectric and an insulator?
Dielectrics and insulators are distinguished primarily by their applications. One of the main differences is that a dielectric can store electrical energy by becoming polarized in an electric field, whereas an insulator resists the flow of electrons to prevent current conduction. Other key differences between them are outlined in the comparison chart below.Definition of DielectricA dielectric material is a type of insulator that contains few or no free electrons. When subjected to an electric fi
Edwiin
08/30/2025
Fault Analysis and Treatment of Oil-Immersed Transformers
Fault Analysis and Treatment of Oil-Immersed Transformers
Oil Leakage at Welded JointsOil leakage at welded joints primarily stems from poor welding quality, such as incomplete or detached welds, and defects like pinholes and gas pores. Although oil-immersed transformers are initially coated with solder and paint during manufacturing, potentially masking these issues temporarily, the defects tend to surface during operation. Additionally, electromagnetic vibration can cause weld cracks, leading to oil leakage.To resolve such leaks, the first critical s
Edwiin
08/29/2025
What losses occur during operation of the transformer? How to reduce losses?
What losses occur during operation of the transformer? How to reduce losses?
Transformers experience various types of losses during operation, primarily categorized into two main types: copper losses and iron losses.Copper LossesCopper losses, also known as I²R losses, are caused by the electrical resistance of the transformer windings—typically made of copper. As current flows through the windings, energy is dissipated in the form of heat. These losses are proportional to the square of the load current (I²R), meaning they increase significantly with high
Rockwell
08/29/2025
Cable Fault Detection, Testing, Location and Repair
Cable Fault Detection, Testing, Location and Repair
I. Methods for Cable Testing and Inspection:Insulation Resistance Test: Use an insulation resistance tester to measure the insulation resistance value of the cable. A high insulation resistance value indicates good insulation, while a low value may suggest insulation problems requiring further investigation.Voltage Withstand Test: Apply a high-voltage test using a high-voltage tester to verify whether the cable can withstand high voltage under its rated operating conditions. Under normal circums
Leon
08/29/2025
Cable Quality Inspection and Cable Detection & Testing
Cable Quality Inspection and Cable Detection & Testing
Power cable quality inspection and cable testing are conducted to ensure that the cable's quality and performance meet specified requirements, thereby guaranteeing the safe and stable operation of power systems. Below are some common contents of power cable quality inspection and cable testing:Visual Inspection: Check the cable surface for physical defects such as damage, deformation, or scratches to ensure the cable's exterior is intact.Dimensional Measurement: Measure dimensional parameters su
Edwiin
08/29/2025
Transformer Detection, Testing, Maintenance and Servicing
Transformer Detection, Testing, Maintenance and Servicing
Transformer testing, inspection, and maintenance are essential tasks to ensure normal operation and extend the service life of transformers. Below are some recommended steps:Visual Inspection: Regularly inspect the transformer's exterior, including the enclosure, cooling system, and oil tank. Ensure the enclosure is intact, free from corrosion, damage, or leakage.Insulation Resistance Testing: Use an insulation resistance tester to check the transformer's insulation system. Verify that the insul
Vziman
08/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!