• Grounding/earthing TransformerUp to 36kV
Grounding/earthing TransformerUp to 36kV
discuss personally
Model
JDS/36/3000
Basic info
Brand ROCKWILL
Model NO. Grounding/earthing TransformerUp to 36kV
Rated voltage 36kV
Rated normal current 3000A
Rated frequency 50/60Hz
Series JDS
Product Detail

Description

This grounding transformer, suitable for systems up to 36kV, is a specialized electrical device. It creates an artificial neutral point in power grids, playing a crucial role in grounding protection. By effectively handling single - phase ground faults, it ensures the stable operation of medium - voltage power systems, whether in urban distribution networks or industrial power setups.

Feature

  • Voltage Adaptability:Designed for up to 36kV systems, it matches the common voltage levels of medium - voltage power grids, ensuring wide - ranging applicability.

  • Fault Handling:Efficiently suppresses arc - grounding overvoltages during single - phase ground faults. It helps reduce ground fault currents, minimizing damage to power grid equipment and enhancing system reliability.

  • Robust Construction:Built with high - quality materials like premium magnetic cores and durable windings. The enclosure is sturdy, resisting harsh environmental factors such as moisture and dust, ensuring long - term stable performance.

  • Safety Enhancement:Provides a reliable neutral grounding solution, preventing abnormal voltage fluctuations and equipment insulation damage, thus safeguarding the safety of the entire power grid and connected electrical devices.

Main technical parameter

Note: This parameter table is for reference. We can offer customize production tailored to client specifications.

Scope of Application

Suitable for scenarios with varying capacities and voltage levels.

  • 35kV and Above Distribution Networks: Transformer windings typically adopt a star (Y) connection with an accessible neutral point, eliminating the need for grounding transformers.

  • 6kV and 10kV Distribution Networks: Transformer windings mostly use delta (Δ) connections without accessible neutral points, requiring grounding transformers to provide a neutral point.

Special Scenarios: When system unbalanced voltage is high, Z-type transformers can meet measurement requirements through balanced design of their three-phase windings. When system unbalanced voltage is low (e.g., fully cable-based networks), the neutral point of Z-type transformers must generate an unbalanced voltage of 30-70V to satisfy measurement criteria.

Purpose and Function: Provides a return path for fault currents, ensuring safety and stability during ground faults.

Operating Principle During Faults: During a ground fault, fault current flows through the transformer’s neutral point. The counteracting magnetic flux generated by reverse current neutralizes impedance.

Voltage and Current Ratings: Rated voltage matches the system’s line voltage. Capable of withstanding maximum fault currents for up to 30 seconds.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High voltage
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
Analysis of Transformer Capacity, Load Rate and Number of Units Selection Issues
The safe and economical operation of power transformers is related to the safety, economy, stability, and reliability of the operations of various industries. The limitations of conditions such as the investment economic indicators for its selection, the economic benefits of maintenance and operation, and the adaptability in the new environment (access of distributed power sources, configuration of energy storage, etc.) make it impossible to include comprehensive factors in other aspects.The cap
Leon
07/17/2025
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
Analysis of the Impact of Immersion on the Performance of Low-Voltage Current Transformers
1 IntroductionLow - voltage current transformers for metering, with a through - core type epoxy resin structure, are widely used in distribution transformer areas and for small - to - medium - sized industrial and commercial electricity consumption. As a range expander for electric energy metering, their performance directly relates to electricity consumption safety and the accuracy of users' trade calculations. Studying long - term immersion's impact on these transformers is practically signifi
Felix Spark
07/17/2025
What is reactive power measurement?
What is reactive power measurement?
The power which exists in the circuit when the voltage and current are out of phase to each other, such type of power is known as the reactive power. The formula measures the reactive power in the circuitReactive Power Measurement & VarmetersReactive power measurement is critical as it indicates circuit power loss: low reactive power worsens load power factor, increasing system losses. Varmeters (volt-ampere reactive meters) measure reactive power and are categorized by circuit phases:Single
Edwiin
07/17/2025
How to Design and Install a Solar PV System?
How to Design and Install a Solar PV System?
Design and Installation of Solar PV SystemsModern society relies on energy for daily needs like industry, heating, transport, and agriculture, mostly met by non-renewable sources (coal, oil, gas). However, these cause environmental harm, are unevenly distributed, and face price volatility due to limited reserves—driving demand for renewable energy.Solar energy, abundant and capable of meeting global needs, stands out. Standalone PV systems (Fig 1) offer energy independence from utilities.
Edwiin
07/17/2025
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
What are the common faults that occur when low-voltage current transformers are combined with other power equipment?
Low-voltage current transformers, as indispensable measurement and protection devices in power systems, often encounter various faults when used in combination with other power equipment due to environmental factors, equipment linkage issues, and improper installation and maintenance. These faults not only affect the normal operation of power equipment but may also endanger personal safety. Therefore, it is necessary to gain an in-depth understanding of fault types, judgment methods, and prevent
Felix Spark
07/17/2025
What are the monitoring methods and future development trends of low-voltage voltage transformers?
What are the monitoring methods and future development trends of low-voltage voltage transformers?
With the continuous advancement of smart grid technology, intelligent monitoring systems are playing an increasingly important role in preventing and addressing faults in voltage transformers. These modern intelligent monitoring systems can collect key parameters from voltage transformers in real time—such as partial discharge levels, temperature, and oil quality—and use data analysis algorithms to assess the health status of the equipment, enabling early fault warnings and precise l
Echo
07/16/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!