• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


6.6kV 10kV 13.2kV 13.8kV Three-phase Resin-insulated Pollution-free Dry-type Power Transformer

  • 6.6kV 10kV 13.2kV 13.8kV Three-phase Resin-insulated Pollution-free Dry-type Power Transformer

Key attributes

Brand ROCKWILL
Model NO. 6.6kV 10kV 13.2kV 13.8kV Three-phase Resin-insulated Pollution-free Dry-type Power Transformer
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 1000kVA
Series SCB

Product descriptions from the supplier

Description

Product overview

As a pioneer in China's power transformer industry, we have specialized in the R&D and manufacturing of power transformer equipment for decades, and established industry standards with core technologies.

SC (B) 10 (11) series of  6.6kV 10kV 13.2kV 13.8kV resin insulated dry power transformer products are in accordance with GB1094.11-2007 and GB/T10228-2015 standards. The product has the advantages of low loss, small size, light weight, low noise, moisture resistance, anti - pollution, anti - crack, impact resistance, flame retardancy, overloading capacity and low local discharge (less than 10PC).This product can be widely used in power transmission and transformation system, hotel, hotel, high-rise building, commercial center, stadium, petrochemical factory, subway, station, airport, offshore drilling platform and other places.It is especially suitable for occasions with special fire protection requirements.

This power transformer is fully compliant with international standards including IEC 60076-1, IEEE C57.12.00, ANSI C57.12.90, AS/NZS 60076.5 and EN 61558-1. It meets quality requirements and is widely adaptable to the operational needs of power grids in multiple overseas regions.

Product features

  • Safety, fire prevention, no pollution, can be directly installed in the load center.

  • Free maintenance, easy installation, low integrated operation cost.

  • Good moisture resistance, can operate at 100% humidity.

  • Low dissipation, low power consumption, low noise, strong heat dissipation capacity, under forced air cooling conditions, the rated load can be run at 130%.

  • Equipped with the perfect temperature protection control system, provides reliable guarantee for the safe operation of the transformer.

  • High reliability. According to the research on the running products, the reliability index of the product has reached the international advanced level.

Conditions of use

  • The elevation is less than or equal to 1000m,

  • Ambient temperature: - 25℃ ~ + 40℃ indoor type transformer of air cooling and forced air cooling.

  • The protection level is IP00, IP20, IP23, etc.

  • Specific requirements may be designed according to the contract.

Product model

  • S: Three-phase

  • C: Resin Casting Type

  • (B): Low-voltage Foil Winding

  • First □: Product Performance Code (10, 11)

  • Second □: Rated Capacity (kVA)

  • Third □: Voltage Class (kV)

Performance Parameters: Technical Parameters of SC(B)10-30~2500/10/0.4 Series Resin Casting Distribution Transformer

The voltage classes of some of these Power Transformer include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV  69kV.72.5kV 88kV 110kV 115kV 123kV 125kV 126kV 132kV 138kV 145kV 150kV 154kV 161kV 170kV  220kV 225kV 230kV 245kV 275kV 330kV 345kV 363kV 380kV 400kV 500kV Power transformers of voltage ,and aboveand customization is available.

Rated Capacity (kVA)

Voltage Combination and Tapping Range

Connection Group

No-load Loss (W)

Load Loss at 120℃ (W)

Short-circuit Impedance %

No-load Current %

Sound Level (db)

Outline Dimensions 

(Length * Width * Height mm)

Total Weight (Kg)

Foot Mounting Dimensions (mm)

High Voltage KV

Tapping Range%

Low Voltage KV

30

6

6.3

6.6

10

10.5

11

± 5

± 2×2.5


0.4

Yyno

Dyn11

190

710

4

2.1

52

900 * 680 * 700

320

400 * 650

50

270

1000

2.1

52

880 * 700 * 710

356

400 * 650

80

370

1380

1.6

53

930 * 700 * 760

467

400 * 650

100

400

1570

1.6

53

960 * 700 * 780

536

550 * 650

125

470

1850

1.4

56

970 * 750 * 850

589

550 * 700

160

540

2130

1.4

56

1000 * 750 * 910

723

550 * 700

200

620

2530

1.2

56

1070 * 800 * 1030

902

710 * 750

250

720

2760

1.2

56

1090 * 800 * 1070

1042

710 * 750

315

880

3470

1

58

1100 * 900 * 1170

1189

710 * 850

400

980

3990

1

58

1130 * 950 * 1285

1425

710 * 900

500

1160

4880

1

60

1170 * 950 * 1325

1607

820 * 900

630

1300

5960

6

0.8

60

1340 * 850 * 1300

1843

820 * 800

800

1520

6960

0.8

62

1380 * 900 * 1405

2127

820 * 850

1000

1770

8130

0.8

62

1440 * 970 * 1475

2517

980 * 920

1250

2090

9690

0.8

63

1520 * 970 * 1555

2925

980 * 920

1600

2450

11730

0.8

64

1540 * 1100 * 1800

3784

980 * 1050

2000

3050

14450

0.7

64

1670 * 1100 * 1815

4323

980 * 1050

2500

3600

17170

0.7

68

1840 * 1100 * 2050

5356

980 * 1050

Performance Parameters: Technical Parameters of SC(B)11 Series kV Resin-insulated Dry-type Transformer

Rated Capacity (kVA)

No-load Loss (w)

Load Loss at 120℃ (W)

No-load Current %

Short-circuit Impedance %

Sound Level dB (A)

Outline Reference Dimensions

Gauge (mm)

Total Weight (kg)

Without Enclosure

 (Length * Width * Height mm)

With Enclosure 

(Length * Width * Height mm)

30

170

710

2.4

4.0

45

850 * 880 * 940

1150 * 1000 * 1200

500

370

50

240

1000

2.4

45

900 * 800 * 1010

1200 * 1000 * 1310

520

80

320

1380

1.8

45

960 * 800 * 1100

1300 * 1200 * 1410

670

100

350

1570

1.8

45

1040 * 800 * 1115

1400 * 1200 * 1450

550

720

125

410

1850

1.6

45

1050 * 800 * 1130

1400 * 1200 * 1450

840

160

480

2130

1.6

45

1150 * 800 * 1185

1400 * 1200 * 1450

990

200

550

2530

1.4

45

1200 * 800 * 1195

1500 * 1200 * 1500

1170

250

630

2760

1.4

45

1200 * 800 * 1265

1500 * 1200 * 1550

1290

315

770

3470

1.2

45

1210 * 800 * 1330

1550 * 1300 * 1650

660

1360

400

850

3990

1.2

45

1250 * 800 * 1430

1500 * 1400 * 1700

1590

500

1020

4880

1.2

45

1270 * 800 * 1535

1600 * 1400 * 1850

1800

630

1130

5960

1.0

6.0

50

1400 * 900 * 1440

1700 * 1400 * 1800

2140

800

1330

6960

1.0

50

1520 * 900 * 1540

1800 * 1400 * 2000

2470

1000

1550

8130

1.0

50

1640 * 960 * 1670

1950 * 1400 * 2000

820

2920

1250

1830

9690

1.0

50

1670 * 960 * 1785

2000 * 1400 * 2100

3640

1600

2140

11730

1.0

50

1780 * 1010 * 1985

2100 * 1500 * 2200

4350

2000

2720

14450

0.8

50

1920 * 1010 * 2070

2250 * 1500 * 2400

5060

2500

3200

17170

0.8

50

2000 * 1010 * 2065

2350 * 1500 * 2500

5880

Note: the above parameters are for reference only and can be customized according to customer requirements

SC (B) 10 series product performance index no-load loss than SC (B) 9 decreased by 10 %, load loss than SC (B) 9 decreased by 5 %;

SC (B) 11 series product performance index no-load loss is 20 % lower than SC (B) 9, load loss is 5 % lower than SC (B) 9;

Implementation standards: GB 1094.11 - 2007, GB / t 10228 - 2015, iec 60076 - 11

 

 

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
  • How to Judge, Detect and Troubleshoot Transformer Core Faults
    1. Hazards, Causes, and Types of Multi-Point Grounding Faults in Transformer Cores1.1 Hazards of Multi-Point Grounding Faults in the CoreUnder normal operation, a transformer core must be grounded at only one point. During operation, alternating magnetic fields surround the windings. Due to electromagnetic induction, parasitic capacitances exist between the high-voltage and low-voltage windings, between the low-voltage winding and the core, and between the core and the tank. The energized windin
    01/27/2026
  • Analysis of Four Major Power Transformer Burnout Cases
    Case OneOn August 1, 2016, a 50kVA distribution transformer at a power supply station suddenly sprayed oil during operation, followed by burning and destruction of the high-voltage fuse. Insulation testing revealed zero megohms from the low-voltage side to ground. Core inspection determined that damage to the low-voltage winding insulation had caused a short circuit. Analysis identified several primary causes for this transformer failure:Overloading: Load management has historically been a weak
    12/23/2025
  • Commissioning Test Procedures for Oil-Immersed Power Transformers
    Transformer Commissioning Tests Procedures1. Non-Porcelain Bushing Tests1.1 Insulation ResistanceSuspend the bushing vertically using a crane or support frame. Measure the insulation resistance between the terminal and the tap/flange using a 2500V insulation resistance meter. The measured values should not deviate significantly from factory values under similar environmental conditions. For capacitor-type bushings rated 66kV and above with voltage sampling small bushings, measure the insulation
    12/23/2025
  • Purpose of Pre-Commissioning Impulse Testing for Power Transformers
    No-Load Full-Voltage Switching Impulse Testing for Newly Commissioned TransformersFor newly commissioned transformers, besides conducting necessary tests according to handover test standards and protection/secondary system tests, no-load full-voltage switching impulse tests are typically performed before official energization.Why Perform Impulse Testing?1. Check for Insulation Weaknesses or Defects in the Transformer and Its CircuitWhen disconnecting a no-load transformer, switching overvoltages
    12/23/2025
  • What are the classification types of power transformers and their applications in energy storage systems?
    Power transformers are core primary equipment in power systems that realize electrical energy transmission and voltage conversion. Through the principle of electromagnetic induction, they convert AC power of one voltage level to another or multiple voltage levels. In the transmission and distribution process, they play a critical role in "step-up transmission and step-down distribution," while in energy storage systems, they perform voltage step-up and step-down functions, ensuring efficient pow
    12/23/2025

Related Solutions

Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.