550kV Dead tank SF6 circuit breaker

  • 550kV Dead tank SF6 circuit breaker

Key attributes

Brand ROCKWILL
Model NO. 550kV Dead tank SF6 circuit breaker
Rated voltage 550kV
Rated normal current 6300A
Rated frequency 50/60Hz
Series LW

Product descriptions from the supplier

Description

Description

550kV Dead tank SF6 circuit breaker products are composed of inlet and outlet line bushings, current transformers, arc extinguishers, frames, operating mechanisms and other components, the products can be used to cut off rated current, fault current or conversion lines, to achieve the control and protection of the power system, widely used in domestic and overseas electric power, metallurgy, Mining, transportation, and utilities industries.

Main Features

  • Ultra-High Voltage Adaptability: Specifically engineered for 550kV UHV systems, it stably handles extreme voltages and currents, ensuring reliable operation of UHV transmission networks.

  • Efficient Arc Extinction & Insulation: Utilizes SF6 gas for rapid arc quenching and high dielectric strength, swiftly interrupting fault currents and minimizing system risks.

  • Dead Tank Sealed Design: Encloses live parts in an SF6-filled metal tank, isolating them from environmental factors. Features robust seismic resistance for harsh climates and challenging terrains.

  • Longevity & Low Maintenance: Boasts extended mechanical and electrical lifespans. Sealed construction reduces component degradation and external corrosion, lowering maintenance frequency and costs.

  • High Integration & Multifunctionality: Integrates bushings, current transformers, and other components to enable current measurement, protective control, and circuit switching capabilities.

  • Comprehensive Safety Features: Equipped with anti-misoperation interlocks and multiple insulation protections to prevent human errors, ensuring personnel safety and equipment stability.

Technical specifications

Documentation Resource Library
Restricted
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ for
Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas
Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • Chinese tank-type filter manufacturer successfully develops 550 kV tank-type filter bank circuit breaker.
    Good news has come from a Chinese tank-type filter manufacturer: its independently developed 550 kV tank-type filter bank circuit breaker has successfully passed all type tests, marking the official completion of the product’s development.In recent years, with the continuous growth of electricity demand, power grids have placed increasingly higher performance demands on electrical equipment. Keeping pace with the times, the Chinese tank-type filter manufacturer has actively responded to the nati
    11/19/2025
  • Hydraulic Leak & SF6 Gas Leakage in Circuit Breakers
    Leakage in Hydraulic Operating MechanismsFor hydraulic mechanisms, leakage can cause short-term frequent pump starting or excessively long re-pressurization time. Severe internal oil seepage in valves may lead to pressure loss failure. If hydraulic oil enters the nitrogen side of the accumulator cylinder, it can cause abnormal pressure rise, which affects the safe operation of SF6 circuit breakers.Apart from failures caused by damaged or abnormal pressure detection devices and pressure component
    10/25/2025
  • 500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
    As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
    05/21/2025
  • Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
    At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5&deg;C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas
    05/21/2025

Related Solutions

  • Dead Tank SF6 Circuit Breaker Solution for African Plateau Regions (Ethiopia)
    Project BackgroundEthiopia, located in the East African plateau, has an average altitude exceeding 3,000 meters. In some areas, winter temperatures can drop to -30&deg;C, accompanied by significant diurnal temperature variations (up to 25&deg;C daily) and intense ultraviolet radiation. The local power system faces the following challenges: SF6 Gas Liquefaction Risk: Traditional Dead Tank SF6 Circuit Breakers are prone to SF6 gas liquefaction at low temperatures (critical liquefaction tem
    05/22/2025
  • South Africa Regional Dead Tank SF6 Circuit Breaker Solution Report
    Ⅰ. Project BackgroundAs the first African country adopting dead tank SF6 circuit breaker technology, South Africa's grid system faces these challenges: Aging Dead Tank SF6 Circuit Breakers: Existing high-voltage circuit breakers exhibit severe aging, particularly legacy dead tank SF6 circuit breakers with increased failure rates. Dead Tank SF6 Circuit Breaker Limitations: In high-altitude regions (>2,000m), conventional dead tank SF6 circuit breakers experience insulation degradation from low
    05/22/2025
  • Rockwill's SF6 Circuit Breaker Solution for 33kV Substations in Nigeria
    Project BackgroundNigeria&rsquo;s tropical climate, characterized by year-round high temperatures (annual average of 35&deg;C) and humidity (&ge;80%), poses significant challenges to the sealing integrity, insulation performance, and gas management of electrical equipment. Rockwill was contracted to upgrade a 33kV substation, deploying its proprietary HV-type SF6 circuit breaker to address critical issues: Sealing Failure Risks: Accelerated aging of seals due to heat and water ingres
    05/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.