Chinese tank-type filter manufacturer successfully develops 550 kV tank-type filter bank circuit breaker.

Baker
Field: News
Engineer
4-6Year
Canada

Good news has come from a Chinese tank-type filter manufacturer: its independently developed 550 kV tank-type filter bank circuit breaker has successfully passed all type tests, marking the official completion of the product’s development.

In recent years, with the continuous growth of electricity demand, power grids have placed increasingly higher performance demands on electrical equipment. Keeping pace with the times, the Chinese tank-type filter manufacturer has actively responded to the national energy development strategy, focused on technological innovation in power equipment, and successfully developed this 550 kV tank-type filter bank circuit breaker with independent intellectual property rights. The launch of this product signifies a major breakthrough in core technologies for filter bank circuit breakers by the Chinese manufacturer and sets a new benchmark for China’s power equipment industry.

550 kV tank-type filter bank circuit breaker.jpg

According to reports, this 550 kV tank-type filter bank circuit breaker adopts an advanced dual-break puffer-type arc-quenching chamber design, combined with a thin-walled, high-strength, lightweight insulating pull rod, significantly enhancing both insulation performance and arc-quenching efficiency. Additionally, the product features excellent switching performance and high-precision phase-selective closing capability, enabling it to easily handle extreme operating conditions such as high-frequency large inrush currents and high recovery voltages, thereby ensuring safe and stable grid operation.

During type testing, the circuit breaker demonstrated outstanding performance, passing multiple rounds of tests consecutively in a single attempt with zero breakdowns. The cumulative number of make-and-break operations reached an industry-leading level. This achievement not only validates the manufacturer’s strength in technological innovation for power equipment but also provides solid technical support for China’s ultra-high-voltage (UHV) DC transmission projects.

A spokesperson from the Chinese tank-type filter manufacturer stated that the company will continue to increase investment in technological innovation, deepen industry-academia-research collaboration, accelerate product iteration and upgrades, and contribute more wisdom and strength to the green and low-carbon transformation of China’s power equipment industry and the sustainable development of global energy initiatives.

Give a tip and encourage the author!
Recommended
Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
12/16/2025
Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
12/16/2025
500kV SF₆ tank circuit breaker insulation pull rod discharge fault cause analysis and treatment
As a key component of circuit breakers, the insulating pull - rod is an important insulating and transmission part of Gas - Insulated Switchgear (GIS) equipment. It is required to have high reliability in terms of mechanical and electrical properties. Generally, insulating pull - rods rarely malfunction, but once a failure occurs, it can have serious consequences for the circuit breaker.The 550kV circuit breaker in a certain power station has a single - break horizontal arrangement, with the mod
05/21/2025
Research on the Application Mode and Operation Monitoring of Tank-type Circuit Breaker Heating Tapes in 500kV Substations in High-Cold Areas
At present, most low - voltage switchgear assemblies in China mainly use SF₆ gas at a pressure of 0.5 - 0.6 MPa as the insulating medium. However, when the ambient temperature drops to around - 32.5°C, the SF₆ gas will quickly liquefy, resulting in serious problems with the insulation and interrupting capabilities of the product. To avoid affecting the operation of low - voltage switchgear assemblies in alpine regions, tracing heaters are often used to prevent the liquefaction of SF₆ gas