• 550kV 740kV Gas Insulated Switchgear HV (GIS)
550kV 740kV Gas Insulated Switchgear HV (GIS)
discuss personally
Model
ZF28-550/4000-63
Basic info
Brand ROCKWILL
Model NO. 550KV 740KV GIS SF6 insulated Switchgear
Rated voltage 550kV
Rated normal current 4000A
Series ZF28
Product Detail

Product Overview:
    ZF28-550 type GIS/ ZH28-550 type HGIS is composed of standard modules through flanged joint, which can meet the demand for substation optimization design through the flexible combination between modules. It saves space and conforms to technical requests.
    This product can be applied to power system, power generation, rail transportation, petrochemical, metallurgy, mining, building materials and other large industrial consumer.

Features and advantages of the product:

  • Fully spring mechanism, high reliability.

  • Excellent breaking ability.

  • The arc extinguish of CB adopts dual break structure, and shunt capacitor to balance the voltage between open contacts, which improves the breaking ability of short-line fault and the breaking current of short circuit is 63kA.

  • E2-M2-C2 circuit breaker; E2 electrical endurance; M2 mechanical endurance.

  • Strong rated current flow capacity.

  • Excellent insulation level, low partial discharge.

  • Excellent corrosion resistance.

  • Advanced Designing tool.

  • Basin-type insolator with aluminium flange; double sealing structure.

  • Strict assembly technology.

  • The domestic first high power spring operation mechanism of circuit breaker has the small volume and is safe and stable, free of maintenance. high reliable and conform to oil free and gas free requirements for operation mechanism.

  •  Interrupter unit adopts shunt capacitor to balance the voltage between open contacts It improves short line  fault breaking capability.

  • Excellent insulation level and low partial discharge. The only company in the industry that can achieve: under the 80% power-frequency withstand voltage (80%×740kV = 592kV), the partial discharge of intervals is lower than 5pC, the partial discharge of the insulator is lower than 3pC. It’s better than the IEC standard that the partial discharge should be lower than 5pC under 1.2 times phase voltage (1.2×550/√3 = 381kV).

  • The insulator quality is stable and reliable. The basin-type insulator pouring process reaches the international advanced level.

Technical Parameters:

image.png

What are the basic requirements for GIS operation?

  • Indoor SF6 equipment room that operators often enter: ventilate at least once per shift, ventilate for 15 minutes, the air exchange volume should be greater than 3-5 times the air volume, and the air outlet should be installed in the lower part of the room; Equipment places that are not frequently visited by operators: ventilate for 15 minutes before entering.

  • During operation, the induced voltage on the shell and frame of GIS should not exceed 36V for the parts that are easily accessible to operation and maintenance personnel.

  • Temperature rise: should not exceed 30K in the part that is easily accessible to operating personnel; The part that is easily accessible to the operator but not touched during operation should not exceed 40K; Individual parts that are not easily accessible to the operator should not exceed 65K.

  • SF6 switchgear inspection at least once a day, unattended substation inspection according to regulations. During the inspection, the visual inspection is mainly carried out, and the equipment is not abnormal, and a record is made.

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Withstand voltage test of high-voltage cables
Withstand voltage test of high-voltage cables
Withstand voltage test is an insulation test, but it is a destructive test that can reveal insulation defects difficult to detect in non-destructive testing.The test cycle for high-voltage cables is three years, and it must be conducted after non-destructive tests. In other words, the withstand voltage test is performed only after all non-destructive tests have been passed.Most high-voltage cables used today are cross-linked polyethylene (XLPE) cables, which can have large cross-sections and cov
Oliver Watts
09/03/2025
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
Analysis of Abnormal Causes of High-Voltage Cable Grounding Circulation and Typical Cases
I. Introduction to Cable Grounding Loop CurrentCables rated 110 kV and above use a single-core structure. The alternating magnetic field generated by the operating current induces a voltage on the metallic sheath. If the sheath forms a closed circuit through the earth, a grounding loop current will flow on the metallic sheath. Excessive grounding loop current (loop current exceeding 50 A, more than 20% of the load current, or a ratio of maximum-to-minimum phase current greater than 3) not only a
Felix Spark
09/03/2025
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
Considerations and Recommendations for Flame-Retardant Selection of High-Voltage Cables
1.Flame-Retardant Cable Classification StandardsThe flame-retardant standard system is divided into two main categories. The first category follows the "Classification of Burning Behavior for Electric and Optical Fiber Cables" GB 31247. Cables complying with this standard system are widely used in densely populated areas such as high-speed railways and subways. This standard imposes strict requirements on parameters such as smoke density, heat release, and total smoke production, and cables typi
James
09/03/2025
Repair of high-voltage cable metallic sheaths
Repair of high-voltage cable metallic sheaths
I. Functions of Metallic Sheaths and Necessity of RepairThe metallic sheath of high-voltage cables is a metal shielding structure laid outside the insulation layer, including types such as lead sheaths, aluminum sheaths, and steel wire armor. Its core functions include mechanical protection (resisting external impact and compression), electrochemical corrosion protection (isolating moisture and soil pollutants), electromagnetic shielding (reducing electromagnetic interference to the environment)
Felix Spark
09/03/2025
What factors need to be considered when designing a transformer?
What factors need to be considered when designing a transformer?
Transformer design is a complex process that requires consideration of multiple factors to ensure safe and efficient operation. In addition, compliance with international and local regulations is essential to guarantee that transformers meet safety and performance standards. Below are key factors to consider in transformer design and the relevant regulations to follow:Transformer Design Factors: Voltage and Frequency: Determine the input and output voltage levels and the operating frequency. The
Vziman
09/02/2025
What failure modes are possible in a transformer? How to identify and fix these failures?
What failure modes are possible in a transformer? How to identify and fix these failures?
Transformers are critical components in power systems, and various failure modes can affect their operation. Timely identification and resolution of these failure modes are essential to prevent costly downtime and ensure system reliability. Below are some common transformer failure modes, along with methods to identify and address them: Insulation FailureIdentification: Insulation failure leads to decreased insulation resistance, which can be detected through insulation resistance testing (megge
Edwiin
09/02/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!